Loading…
A novel method for the determination of 1,5-anhydroglucitol, a glycemic marker, in human urine utilizing hydrophilic interaction liquid chromatography/MS
Plasma levels of 1,5-anhydroglucitol (1-deoxyglucose), a short-term marker of glycemic control, have been measured and used clinically in Japan since the early 1990s. Plasma levels of 1,5-anhydroglucitol are typically measured using either a commercially available enzymatic kit or GC/MS. A more sens...
Saved in:
Published in: | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2008-10, Vol.873 (2), p.144-150 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 150 |
container_issue | 2 |
container_start_page | 144 |
container_title | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences |
container_volume | 873 |
creator | ONORATO, Joelle M LANGISH, Robert A SHIPKOVA, Petia A SANDERS, Mark WANG, Jennifer KWAGH, Jae DUTTA, Sanjoy |
description | Plasma levels of 1,5-anhydroglucitol (1-deoxyglucose), a short-term marker of glycemic control, have been measured and used clinically in Japan since the early 1990s. Plasma levels of 1,5-anhydroglucitol are typically measured using either a commercially available enzymatic kit or GC/MS. A more sensitive method is needed for the analysis of 1,5-anhydroglucitol in urine, where levels are significantly lower than in plasma. We have developed a sensitive and selective LC/MS(3) assay utilizing hydrophilic interaction liquid chromatography and ion trap mass spectrometry for the quantitative determination of 1,5-anhydroglucitol in human urine. Diluted human urine samples were analyzed by LC/MS(3) using an APCI source operated in the negative ionization mode. Use of an ion trap allowed monitoring of MS(3) transitions for both 1,5-anhydroglucitol and the internal standard which provided sufficient selectivity and sensitivity for analysis from 50 microL of human urine. Quantitation of 1,5-anhydroglucitol levels in urine was accomplished using a calibration curve generated in water (calibration range 50 ng/mL to 10 microg/mL). Method ruggedness and reproducibility were evaluated by determining the intra- and inter-day accuracies and precision of the assay, as well as the bench-top and freeze-thaw stability. For both inter- and intra-assay evaluations, the accuracy of the assay was found to be acceptable, with the concentrations of all QCs tested not deviating more than 8% from theoretical. Four-hour bench-top and freeze-thaw stabilities were also evaluated; 1,5-anhydroglucitol was found to be stable at room temperature ( |
doi_str_mv | 10.1016/j.jchromb.2008.08.006 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_69664846</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69664846</sourcerecordid><originalsourceid>FETCH-LOGICAL-p154t-777b68a02d93026846c8e6b8854bddcb6e1f891feb2a5b330a9266090f0a09ec3</originalsourceid><addsrcrecordid>eNo9kM-KFDEQh4Mo7rr6CEouepqerSTdSfq4LOsfWPGggrehOp2ezphOetNpYXwT39Y4jkJBVcFXH_yKkJcMtgyYvD5sD2ZMceq2HEBv_xTIR-SSaSUqoeS3x2VuFFTABb8gz5blAMAUKPGUXBRIQqv0Jfl1Q0P8YT2dbB5jT4eYaB4t7W22aXIBs4uBxoGyTVNhGI99inu_Gpej31Cke380dnKGTpi-27ShLtBxnTDQNblg6Zqddz9d2NPT6TyW1RSo2NGc3N49rK6npzCY4z7hPB6vP35-Tp4M6Bf74tyvyNe3d19u31f3n959uL25r2bW1LlSSnVSI_C-FcClrqXRVnZaN3XX96aTlg26ZYPtODadEIAtlyU8DIDQWiOuyJu_3jnFh9UueTe5xVjvMdi4LjvZSlkXbQFfncG1m2y_m5MroY-7f88swOszgItBPyQMxi3_OQ6qFjVX4jfff4jy</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69664846</pqid></control><display><type>article</type><title>A novel method for the determination of 1,5-anhydroglucitol, a glycemic marker, in human urine utilizing hydrophilic interaction liquid chromatography/MS</title><source>ScienceDirect Journals</source><creator>ONORATO, Joelle M ; LANGISH, Robert A ; SHIPKOVA, Petia A ; SANDERS, Mark ; WANG, Jennifer ; KWAGH, Jae ; DUTTA, Sanjoy</creator><creatorcontrib>ONORATO, Joelle M ; LANGISH, Robert A ; SHIPKOVA, Petia A ; SANDERS, Mark ; WANG, Jennifer ; KWAGH, Jae ; DUTTA, Sanjoy</creatorcontrib><description>Plasma levels of 1,5-anhydroglucitol (1-deoxyglucose), a short-term marker of glycemic control, have been measured and used clinically in Japan since the early 1990s. Plasma levels of 1,5-anhydroglucitol are typically measured using either a commercially available enzymatic kit or GC/MS. A more sensitive method is needed for the analysis of 1,5-anhydroglucitol in urine, where levels are significantly lower than in plasma. We have developed a sensitive and selective LC/MS(3) assay utilizing hydrophilic interaction liquid chromatography and ion trap mass spectrometry for the quantitative determination of 1,5-anhydroglucitol in human urine. Diluted human urine samples were analyzed by LC/MS(3) using an APCI source operated in the negative ionization mode. Use of an ion trap allowed monitoring of MS(3) transitions for both 1,5-anhydroglucitol and the internal standard which provided sufficient selectivity and sensitivity for analysis from 50 microL of human urine. Quantitation of 1,5-anhydroglucitol levels in urine was accomplished using a calibration curve generated in water (calibration range 50 ng/mL to 10 microg/mL). Method ruggedness and reproducibility were evaluated by determining the intra- and inter-day accuracies and precision of the assay, as well as the bench-top and freeze-thaw stability. For both inter- and intra-assay evaluations, the accuracy of the assay was found to be acceptable, with the concentrations of all QCs tested not deviating more than 8% from theoretical. Four-hour bench-top and freeze-thaw stabilities were also evaluated; 1,5-anhydroglucitol was found to be stable at room temperature (<18% deviation from theoretical) and during 3 freeze-thaw cycles (<1% deviation from theoretical, except at the lowest QC level). The LC/MS(3) assay was then used to successfully determine the concentration of 1,5-AG in more than 200 urine samples from diabetic patients enrolled in a clinical study.</description><identifier>ISSN: 1570-0232</identifier><identifier>EISSN: 1873-376X</identifier><identifier>DOI: 10.1016/j.jchromb.2008.08.006</identifier><identifier>PMID: 18760978</identifier><language>eng</language><publisher>Amsterdam: Elsevier Science</publisher><subject>Analysis ; Analytical, structural and metabolic biochemistry ; Biological and medical sciences ; Biomarkers ; Chromatography, High Pressure Liquid - methods ; Deoxyglucose - urine ; Diabetes Mellitus - diagnosis ; Diabetes Mellitus - urine ; Female ; Fundamental and applied biological sciences. Psychology ; General pharmacology ; Humans ; Male ; Mass Spectrometry - methods ; Medical sciences ; Pharmacology. Drug treatments ; Sensitivity and Specificity</subject><ispartof>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2008-10, Vol.873 (2), p.144-150</ispartof><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=20743427$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18760978$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ONORATO, Joelle M</creatorcontrib><creatorcontrib>LANGISH, Robert A</creatorcontrib><creatorcontrib>SHIPKOVA, Petia A</creatorcontrib><creatorcontrib>SANDERS, Mark</creatorcontrib><creatorcontrib>WANG, Jennifer</creatorcontrib><creatorcontrib>KWAGH, Jae</creatorcontrib><creatorcontrib>DUTTA, Sanjoy</creatorcontrib><title>A novel method for the determination of 1,5-anhydroglucitol, a glycemic marker, in human urine utilizing hydrophilic interaction liquid chromatography/MS</title><title>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences</title><addtitle>J Chromatogr B Analyt Technol Biomed Life Sci</addtitle><description>Plasma levels of 1,5-anhydroglucitol (1-deoxyglucose), a short-term marker of glycemic control, have been measured and used clinically in Japan since the early 1990s. Plasma levels of 1,5-anhydroglucitol are typically measured using either a commercially available enzymatic kit or GC/MS. A more sensitive method is needed for the analysis of 1,5-anhydroglucitol in urine, where levels are significantly lower than in plasma. We have developed a sensitive and selective LC/MS(3) assay utilizing hydrophilic interaction liquid chromatography and ion trap mass spectrometry for the quantitative determination of 1,5-anhydroglucitol in human urine. Diluted human urine samples were analyzed by LC/MS(3) using an APCI source operated in the negative ionization mode. Use of an ion trap allowed monitoring of MS(3) transitions for both 1,5-anhydroglucitol and the internal standard which provided sufficient selectivity and sensitivity for analysis from 50 microL of human urine. Quantitation of 1,5-anhydroglucitol levels in urine was accomplished using a calibration curve generated in water (calibration range 50 ng/mL to 10 microg/mL). Method ruggedness and reproducibility were evaluated by determining the intra- and inter-day accuracies and precision of the assay, as well as the bench-top and freeze-thaw stability. For both inter- and intra-assay evaluations, the accuracy of the assay was found to be acceptable, with the concentrations of all QCs tested not deviating more than 8% from theoretical. Four-hour bench-top and freeze-thaw stabilities were also evaluated; 1,5-anhydroglucitol was found to be stable at room temperature (<18% deviation from theoretical) and during 3 freeze-thaw cycles (<1% deviation from theoretical, except at the lowest QC level). The LC/MS(3) assay was then used to successfully determine the concentration of 1,5-AG in more than 200 urine samples from diabetic patients enrolled in a clinical study.</description><subject>Analysis</subject><subject>Analytical, structural and metabolic biochemistry</subject><subject>Biological and medical sciences</subject><subject>Biomarkers</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Deoxyglucose - urine</subject><subject>Diabetes Mellitus - diagnosis</subject><subject>Diabetes Mellitus - urine</subject><subject>Female</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General pharmacology</subject><subject>Humans</subject><subject>Male</subject><subject>Mass Spectrometry - methods</subject><subject>Medical sciences</subject><subject>Pharmacology. Drug treatments</subject><subject>Sensitivity and Specificity</subject><issn>1570-0232</issn><issn>1873-376X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNo9kM-KFDEQh4Mo7rr6CEouepqerSTdSfq4LOsfWPGggrehOp2ezphOetNpYXwT39Y4jkJBVcFXH_yKkJcMtgyYvD5sD2ZMceq2HEBv_xTIR-SSaSUqoeS3x2VuFFTABb8gz5blAMAUKPGUXBRIQqv0Jfl1Q0P8YT2dbB5jT4eYaB4t7W22aXIBs4uBxoGyTVNhGI99inu_Gpej31Cke380dnKGTpi-27ShLtBxnTDQNblg6Zqddz9d2NPT6TyW1RSo2NGc3N49rK6npzCY4z7hPB6vP35-Tp4M6Bf74tyvyNe3d19u31f3n959uL25r2bW1LlSSnVSI_C-FcClrqXRVnZaN3XX96aTlg26ZYPtODadEIAtlyU8DIDQWiOuyJu_3jnFh9UueTe5xVjvMdi4LjvZSlkXbQFfncG1m2y_m5MroY-7f88swOszgItBPyQMxi3_OQ6qFjVX4jfff4jy</recordid><startdate>20081001</startdate><enddate>20081001</enddate><creator>ONORATO, Joelle M</creator><creator>LANGISH, Robert A</creator><creator>SHIPKOVA, Petia A</creator><creator>SANDERS, Mark</creator><creator>WANG, Jennifer</creator><creator>KWAGH, Jae</creator><creator>DUTTA, Sanjoy</creator><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20081001</creationdate><title>A novel method for the determination of 1,5-anhydroglucitol, a glycemic marker, in human urine utilizing hydrophilic interaction liquid chromatography/MS</title><author>ONORATO, Joelle M ; LANGISH, Robert A ; SHIPKOVA, Petia A ; SANDERS, Mark ; WANG, Jennifer ; KWAGH, Jae ; DUTTA, Sanjoy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p154t-777b68a02d93026846c8e6b8854bddcb6e1f891feb2a5b330a9266090f0a09ec3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Analysis</topic><topic>Analytical, structural and metabolic biochemistry</topic><topic>Biological and medical sciences</topic><topic>Biomarkers</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Deoxyglucose - urine</topic><topic>Diabetes Mellitus - diagnosis</topic><topic>Diabetes Mellitus - urine</topic><topic>Female</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General pharmacology</topic><topic>Humans</topic><topic>Male</topic><topic>Mass Spectrometry - methods</topic><topic>Medical sciences</topic><topic>Pharmacology. Drug treatments</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ONORATO, Joelle M</creatorcontrib><creatorcontrib>LANGISH, Robert A</creatorcontrib><creatorcontrib>SHIPKOVA, Petia A</creatorcontrib><creatorcontrib>SANDERS, Mark</creatorcontrib><creatorcontrib>WANG, Jennifer</creatorcontrib><creatorcontrib>KWAGH, Jae</creatorcontrib><creatorcontrib>DUTTA, Sanjoy</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ONORATO, Joelle M</au><au>LANGISH, Robert A</au><au>SHIPKOVA, Petia A</au><au>SANDERS, Mark</au><au>WANG, Jennifer</au><au>KWAGH, Jae</au><au>DUTTA, Sanjoy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A novel method for the determination of 1,5-anhydroglucitol, a glycemic marker, in human urine utilizing hydrophilic interaction liquid chromatography/MS</atitle><jtitle>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences</jtitle><addtitle>J Chromatogr B Analyt Technol Biomed Life Sci</addtitle><date>2008-10-01</date><risdate>2008</risdate><volume>873</volume><issue>2</issue><spage>144</spage><epage>150</epage><pages>144-150</pages><issn>1570-0232</issn><eissn>1873-376X</eissn><abstract>Plasma levels of 1,5-anhydroglucitol (1-deoxyglucose), a short-term marker of glycemic control, have been measured and used clinically in Japan since the early 1990s. Plasma levels of 1,5-anhydroglucitol are typically measured using either a commercially available enzymatic kit or GC/MS. A more sensitive method is needed for the analysis of 1,5-anhydroglucitol in urine, where levels are significantly lower than in plasma. We have developed a sensitive and selective LC/MS(3) assay utilizing hydrophilic interaction liquid chromatography and ion trap mass spectrometry for the quantitative determination of 1,5-anhydroglucitol in human urine. Diluted human urine samples were analyzed by LC/MS(3) using an APCI source operated in the negative ionization mode. Use of an ion trap allowed monitoring of MS(3) transitions for both 1,5-anhydroglucitol and the internal standard which provided sufficient selectivity and sensitivity for analysis from 50 microL of human urine. Quantitation of 1,5-anhydroglucitol levels in urine was accomplished using a calibration curve generated in water (calibration range 50 ng/mL to 10 microg/mL). Method ruggedness and reproducibility were evaluated by determining the intra- and inter-day accuracies and precision of the assay, as well as the bench-top and freeze-thaw stability. For both inter- and intra-assay evaluations, the accuracy of the assay was found to be acceptable, with the concentrations of all QCs tested not deviating more than 8% from theoretical. Four-hour bench-top and freeze-thaw stabilities were also evaluated; 1,5-anhydroglucitol was found to be stable at room temperature (<18% deviation from theoretical) and during 3 freeze-thaw cycles (<1% deviation from theoretical, except at the lowest QC level). The LC/MS(3) assay was then used to successfully determine the concentration of 1,5-AG in more than 200 urine samples from diabetic patients enrolled in a clinical study.</abstract><cop>Amsterdam</cop><pub>Elsevier Science</pub><pmid>18760978</pmid><doi>10.1016/j.jchromb.2008.08.006</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1570-0232 |
ispartof | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2008-10, Vol.873 (2), p.144-150 |
issn | 1570-0232 1873-376X |
language | eng |
recordid | cdi_proquest_miscellaneous_69664846 |
source | ScienceDirect Journals |
subjects | Analysis Analytical, structural and metabolic biochemistry Biological and medical sciences Biomarkers Chromatography, High Pressure Liquid - methods Deoxyglucose - urine Diabetes Mellitus - diagnosis Diabetes Mellitus - urine Female Fundamental and applied biological sciences. Psychology General pharmacology Humans Male Mass Spectrometry - methods Medical sciences Pharmacology. Drug treatments Sensitivity and Specificity |
title | A novel method for the determination of 1,5-anhydroglucitol, a glycemic marker, in human urine utilizing hydrophilic interaction liquid chromatography/MS |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A31%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20novel%20method%20for%20the%20determination%20of%201,5-anhydroglucitol,%20a%20glycemic%20marker,%20in%20human%20urine%20utilizing%20hydrophilic%20interaction%20liquid%20chromatography/MS&rft.jtitle=Journal%20of%20chromatography.%20B,%20Analytical%20technologies%20in%20the%20biomedical%20and%20life%20sciences&rft.au=ONORATO,%20Joelle%20M&rft.date=2008-10-01&rft.volume=873&rft.issue=2&rft.spage=144&rft.epage=150&rft.pages=144-150&rft.issn=1570-0232&rft.eissn=1873-376X&rft_id=info:doi/10.1016/j.jchromb.2008.08.006&rft_dat=%3Cproquest_pubme%3E69664846%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p154t-777b68a02d93026846c8e6b8854bddcb6e1f891feb2a5b330a9266090f0a09ec3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=69664846&rft_id=info:pmid/18760978&rfr_iscdi=true |