Loading…

Delivery Room Management of Extremely Low Birth Weight Infants: Spontaneous Breathing or Intubation?

To study the effect of two different delivery room (DR) policies on the rate of endotracheal intubation and mechanical ventilation (EI/MV) and short term morbidity in extremely low birth weight infants (ELBWI; /=24 weeks). Retrospective cohort study of 123 inborn ELBWIs born in 1994 and in 1996. DR...

Full description

Saved in:
Bibliographic Details
Published in:Pediatrics (Evanston) 1999-05, Vol.103 (5), p.961-967
Main Authors: Lindner, Wolfgang, Vossbeck, Sabine, Hummler, Helmut, Pohlandt, Frank
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To study the effect of two different delivery room (DR) policies on the rate of endotracheal intubation and mechanical ventilation (EI/MV) and short term morbidity in extremely low birth weight infants (ELBWI; /=24 weeks). Retrospective cohort study of 123 inborn ELBWIs born in 1994 and in 1996. DR policies have changed. Until 1994, ELBWIs were intubated immediately after delivery when presenting the slightest signs of respiratory distress or asphyxia after initial resuscitation using a face mask and a handbag. During 1995, the guidelines for respiratory support were changed. In 1996, continuous (15 to 20 seconds), pressure controlled (20 to 25 cm H2O) inflation of the lungs using a nasal pharyngeal tube, followed by continuous positive airway pressure (CPAP; 4 to 6 cm H2O) was applied to all ELBWIs immediately after delivery to establish a functional residual capacity and perhaps to avoid EI/MV. In addition to the changes in respiratory support, the prevention of conductive and evaporative heat loss was improved in 1996. For analysis of morbidity and mortality, infants were matched for gestational age and birth weight. The rate of EI/MV in the DR decreased from 84% in 1994 to 40% in 1996. In 1996, 25% of the ELBWIs were never intubated (7% in 1994), but 35% of the ELBWIs needed secondary EI/MV, primarily because of respiratory distress syndrome (RDS). Initial ventilator settings, ventilator days, mortality, and morbidity were not different between ELBWIs with EI/MV in the DR and infants with secondary EI/MV attributable to RDS in the intensive care unit. ELBWIs with no EI/MV that was caused by RDS had a lower morbidity (ie, bronchopulmonary dysplasia, intraventricular hemorrhage >grade 2 and/or periventricular leukomalacia), mortality, and fewer hospital days (mean: 79 vs 105 days). The incidence of gastrointestinal adverse effects like feeding intolerance or necrotizing enterocolitis was not increased in 1996. PaCO2 was significantly higher at admission to the neonatal unit in ELBWIs with CPAP in 1996 (54 +/- 15 mm Hg, 7.2 +/- 2.0 kPa) compared with infants with EI/MV in 1994 (38 +/- 11 mm Hg, 5.1 +/- 1. 5 kPa. A total of 26% of spontaneously breathing infants had hypercapnia (PaCO2 >/=60 mm Hg [8.0 kPa]), compared with 7% of infants with EI/MV in 1994. Within the first few hours of life, PaCO2 decreased to 46 (32 to 57) mm Hg (6.1 [4.3 to 7.6] kPa) in never intubated ELBWIs (n = 17), but increased to 70 (57 to 81) mm Hg (9.3 [7.6 to 10.8] kPa)
ISSN:0031-4005
1098-4275
DOI:10.1542/peds.103.5.961