Loading…

Transarterial ductal occlusion with the amplatzer vascular plug in 31 dogs

Background: Transarterial ductal occlusion with the Amplatzer vascular plug was first reported in dogs by Hogan et al in 2005. Hypothesis: Use of the Amplatzer vascular plug is a safe, efficacious method of patent ductus arteriosus (PDA) occlusion. Animals: Thirty‐one client‐owned dogs with PDA. Met...

Full description

Saved in:
Bibliographic Details
Published in:Journal of veterinary internal medicine 2008-11, Vol.22 (6), p.1348-1352
Main Authors: Achen, S.E, Miller, M.W, Gordon, S.G, Saunders, A.B, Roland, R.M, Drourr, L.T
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4755-863e4defe9cb069fb50bdfc9a55c1ff73e1a0f28fd5999a8154472148db3aff3
cites cdi_FETCH-LOGICAL-c4755-863e4defe9cb069fb50bdfc9a55c1ff73e1a0f28fd5999a8154472148db3aff3
container_end_page 1352
container_issue 6
container_start_page 1348
container_title Journal of veterinary internal medicine
container_volume 22
creator Achen, S.E
Miller, M.W
Gordon, S.G
Saunders, A.B
Roland, R.M
Drourr, L.T
description Background: Transarterial ductal occlusion with the Amplatzer vascular plug was first reported in dogs by Hogan et al in 2005. Hypothesis: Use of the Amplatzer vascular plug is a safe, efficacious method of patent ductus arteriosus (PDA) occlusion. Animals: Thirty‐one client‐owned dogs with PDA. Methods: Records of 31 dogs in which transarterial occlusion of PDA with an Amplatzer vascular plug was attempted were reviewed. Results: All dogs had a type II PDA, with 27 dogs having type IIA morphology and 4 dogs having type IIB morphology. Appropriate device deployment was achieved in 29 of 31 dogs. Postdeployment angiography in 21 dogs documented complete occlusion in 10 dogs, trivial residual flow in 5 dogs, mild residual flow in 2 dogs, moderate residual flow in 3 dogs, and severe residual flow in 1 dog. Transthoracic color Doppler echocardiography documented complete occlusion in 22 dogs, whereas 2 dogs had trivial residual flow, 2 dogs had mild residual flow, 2 dogs had mild to moderate residual flow, and 1 dog had severe residual flow. Of the 7 dogs with residual flow, 2 had complete occlusion 2–4 months postoperatively, 1 had moderate residual flow 1 month postoperatively, and 4 were lost to follow‐up. One dog required a larger device than was able to be deployed through the largest sheath placed in the femoral artery. Pulmonary embolization of the device occurred in 1 dog. Conclusion: We conclude that ductal occlusion with an Amplatzer vascular plug is a safe and efficacious therapy for PDA in dogs.
doi_str_mv 10.1111/j.1939-1676.2008.0185.x
format article
fullrecord <record><control><sourceid>proquest_24P</sourceid><recordid>TN_cdi_proquest_miscellaneous_69790839</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69790839</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4755-863e4defe9cb069fb50bdfc9a55c1ff73e1a0f28fd5999a8154472148db3aff3</originalsourceid><addsrcrecordid>eNqNkE1v1DAQhi0EokvhL1CfuCXYcRzbEhdUQT_UFlVd4DhyHHvrxbvZ2gnd8utxlFW5Ylma0eh5Z6QHoRNKSprfx3VJFVMFbURTVoTIklDJy_0LtHiev0QLIhUtmqYmR-hNSmtCKs65eI2OqBQqf7ZAl8uot0nHwUavA-5GM-TSGxPG5PstfvTDPR7uLdabXdDDHxvxb53MGHTEuzCusN9iRnHXr9Jb9MrpkOy7Qz1Gy69flqfnxdW3s4vTz1eFqQXnhWyYrTvrrDItaZRrOWk7Z5Tm3FDnBLNUE1dJ13GllJaU17WoaC27lmnn2DH6MK_dxf5htGmAjU_GhqC3th8TNEooIpnKoJhBE_uUonWwi36j4xNQApNFWMNkCyZbMFmEySLsc_L94cTYbmz3L3fQloFPM_Dog336371w-ePiOnc5Xsxxnwa7f47r-AsawQSHnzdncH57c31LFYG7zJ_MvNM96FX0Cb7fVYQyQnlDqCDsL9DRmZ4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69790839</pqid></control><display><type>article</type><title>Transarterial ductal occlusion with the amplatzer vascular plug in 31 dogs</title><source>Wiley-Blackwell Open Access Collection</source><creator>Achen, S.E ; Miller, M.W ; Gordon, S.G ; Saunders, A.B ; Roland, R.M ; Drourr, L.T</creator><creatorcontrib>Achen, S.E ; Miller, M.W ; Gordon, S.G ; Saunders, A.B ; Roland, R.M ; Drourr, L.T</creatorcontrib><description>Background: Transarterial ductal occlusion with the Amplatzer vascular plug was first reported in dogs by Hogan et al in 2005. Hypothesis: Use of the Amplatzer vascular plug is a safe, efficacious method of patent ductus arteriosus (PDA) occlusion. Animals: Thirty‐one client‐owned dogs with PDA. Methods: Records of 31 dogs in which transarterial occlusion of PDA with an Amplatzer vascular plug was attempted were reviewed. Results: All dogs had a type II PDA, with 27 dogs having type IIA morphology and 4 dogs having type IIB morphology. Appropriate device deployment was achieved in 29 of 31 dogs. Postdeployment angiography in 21 dogs documented complete occlusion in 10 dogs, trivial residual flow in 5 dogs, mild residual flow in 2 dogs, moderate residual flow in 3 dogs, and severe residual flow in 1 dog. Transthoracic color Doppler echocardiography documented complete occlusion in 22 dogs, whereas 2 dogs had trivial residual flow, 2 dogs had mild residual flow, 2 dogs had mild to moderate residual flow, and 1 dog had severe residual flow. Of the 7 dogs with residual flow, 2 had complete occlusion 2–4 months postoperatively, 1 had moderate residual flow 1 month postoperatively, and 4 were lost to follow‐up. One dog required a larger device than was able to be deployed through the largest sheath placed in the femoral artery. Pulmonary embolization of the device occurred in 1 dog. Conclusion: We conclude that ductal occlusion with an Amplatzer vascular plug is a safe and efficacious therapy for PDA in dogs.</description><identifier>ISSN: 0891-6640</identifier><identifier>EISSN: 1939-1676</identifier><identifier>DOI: 10.1111/j.1939-1676.2008.0185.x</identifier><identifier>PMID: 18798793</identifier><language>eng</language><publisher>Malden, USA: Blackwell Publishing Inc</publisher><subject>Animals ; Cardiac Catheterization - instrumentation ; Cardiac Catheterization - veterinary ; Cardiac Surgical Procedures - instrumentation ; Cardiac Surgical Procedures - veterinary ; Congenital heart disease ; Dog Diseases - surgery ; Dogs ; Ductus Arteriosus, Patent - surgery ; Ductus Arteriosus, Patent - veterinary ; Embolization, Therapeutic - instrumentation ; Embolization, Therapeutic - veterinary ; Equipment Design ; heart diseases ; PDA ; Prostheses and Implants - veterinary ; surgery ; surgical equipment</subject><ispartof>Journal of veterinary internal medicine, 2008-11, Vol.22 (6), p.1348-1352</ispartof><rights>Copyright © 2008 by the American College of Veterinary Internal Medicine</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4755-863e4defe9cb069fb50bdfc9a55c1ff73e1a0f28fd5999a8154472148db3aff3</citedby><cites>FETCH-LOGICAL-c4755-863e4defe9cb069fb50bdfc9a55c1ff73e1a0f28fd5999a8154472148db3aff3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1939-1676.2008.0185.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1939-1676.2008.0185.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,11560,27922,27923,46050,46474</link.rule.ids><linktorsrc>$$Uhttps://onlinelibrary.wiley.com/doi/abs/10.1111%2Fj.1939-1676.2008.0185.x$$EView_record_in_Wiley-Blackwell$$FView_record_in_$$GWiley-Blackwell</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18798793$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Achen, S.E</creatorcontrib><creatorcontrib>Miller, M.W</creatorcontrib><creatorcontrib>Gordon, S.G</creatorcontrib><creatorcontrib>Saunders, A.B</creatorcontrib><creatorcontrib>Roland, R.M</creatorcontrib><creatorcontrib>Drourr, L.T</creatorcontrib><title>Transarterial ductal occlusion with the amplatzer vascular plug in 31 dogs</title><title>Journal of veterinary internal medicine</title><addtitle>J Vet Intern Med</addtitle><description>Background: Transarterial ductal occlusion with the Amplatzer vascular plug was first reported in dogs by Hogan et al in 2005. Hypothesis: Use of the Amplatzer vascular plug is a safe, efficacious method of patent ductus arteriosus (PDA) occlusion. Animals: Thirty‐one client‐owned dogs with PDA. Methods: Records of 31 dogs in which transarterial occlusion of PDA with an Amplatzer vascular plug was attempted were reviewed. Results: All dogs had a type II PDA, with 27 dogs having type IIA morphology and 4 dogs having type IIB morphology. Appropriate device deployment was achieved in 29 of 31 dogs. Postdeployment angiography in 21 dogs documented complete occlusion in 10 dogs, trivial residual flow in 5 dogs, mild residual flow in 2 dogs, moderate residual flow in 3 dogs, and severe residual flow in 1 dog. Transthoracic color Doppler echocardiography documented complete occlusion in 22 dogs, whereas 2 dogs had trivial residual flow, 2 dogs had mild residual flow, 2 dogs had mild to moderate residual flow, and 1 dog had severe residual flow. Of the 7 dogs with residual flow, 2 had complete occlusion 2–4 months postoperatively, 1 had moderate residual flow 1 month postoperatively, and 4 were lost to follow‐up. One dog required a larger device than was able to be deployed through the largest sheath placed in the femoral artery. Pulmonary embolization of the device occurred in 1 dog. Conclusion: We conclude that ductal occlusion with an Amplatzer vascular plug is a safe and efficacious therapy for PDA in dogs.</description><subject>Animals</subject><subject>Cardiac Catheterization - instrumentation</subject><subject>Cardiac Catheterization - veterinary</subject><subject>Cardiac Surgical Procedures - instrumentation</subject><subject>Cardiac Surgical Procedures - veterinary</subject><subject>Congenital heart disease</subject><subject>Dog Diseases - surgery</subject><subject>Dogs</subject><subject>Ductus Arteriosus, Patent - surgery</subject><subject>Ductus Arteriosus, Patent - veterinary</subject><subject>Embolization, Therapeutic - instrumentation</subject><subject>Embolization, Therapeutic - veterinary</subject><subject>Equipment Design</subject><subject>heart diseases</subject><subject>PDA</subject><subject>Prostheses and Implants - veterinary</subject><subject>surgery</subject><subject>surgical equipment</subject><issn>0891-6640</issn><issn>1939-1676</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqNkE1v1DAQhi0EokvhL1CfuCXYcRzbEhdUQT_UFlVd4DhyHHvrxbvZ2gnd8utxlFW5Ylma0eh5Z6QHoRNKSprfx3VJFVMFbURTVoTIklDJy_0LtHiev0QLIhUtmqYmR-hNSmtCKs65eI2OqBQqf7ZAl8uot0nHwUavA-5GM-TSGxPG5PstfvTDPR7uLdabXdDDHxvxb53MGHTEuzCusN9iRnHXr9Jb9MrpkOy7Qz1Gy69flqfnxdW3s4vTz1eFqQXnhWyYrTvrrDItaZRrOWk7Z5Tm3FDnBLNUE1dJ13GllJaU17WoaC27lmnn2DH6MK_dxf5htGmAjU_GhqC3th8TNEooIpnKoJhBE_uUonWwi36j4xNQApNFWMNkCyZbMFmEySLsc_L94cTYbmz3L3fQloFPM_Dog336371w-ePiOnc5Xsxxnwa7f47r-AsawQSHnzdncH57c31LFYG7zJ_MvNM96FX0Cb7fVYQyQnlDqCDsL9DRmZ4</recordid><startdate>200811</startdate><enddate>200811</enddate><creator>Achen, S.E</creator><creator>Miller, M.W</creator><creator>Gordon, S.G</creator><creator>Saunders, A.B</creator><creator>Roland, R.M</creator><creator>Drourr, L.T</creator><general>Blackwell Publishing Inc</general><scope>FBQ</scope><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200811</creationdate><title>Transarterial ductal occlusion with the amplatzer vascular plug in 31 dogs</title><author>Achen, S.E ; Miller, M.W ; Gordon, S.G ; Saunders, A.B ; Roland, R.M ; Drourr, L.T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4755-863e4defe9cb069fb50bdfc9a55c1ff73e1a0f28fd5999a8154472148db3aff3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Animals</topic><topic>Cardiac Catheterization - instrumentation</topic><topic>Cardiac Catheterization - veterinary</topic><topic>Cardiac Surgical Procedures - instrumentation</topic><topic>Cardiac Surgical Procedures - veterinary</topic><topic>Congenital heart disease</topic><topic>Dog Diseases - surgery</topic><topic>Dogs</topic><topic>Ductus Arteriosus, Patent - surgery</topic><topic>Ductus Arteriosus, Patent - veterinary</topic><topic>Embolization, Therapeutic - instrumentation</topic><topic>Embolization, Therapeutic - veterinary</topic><topic>Equipment Design</topic><topic>heart diseases</topic><topic>PDA</topic><topic>Prostheses and Implants - veterinary</topic><topic>surgery</topic><topic>surgical equipment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Achen, S.E</creatorcontrib><creatorcontrib>Miller, M.W</creatorcontrib><creatorcontrib>Gordon, S.G</creatorcontrib><creatorcontrib>Saunders, A.B</creatorcontrib><creatorcontrib>Roland, R.M</creatorcontrib><creatorcontrib>Drourr, L.T</creatorcontrib><collection>AGRIS</collection><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of veterinary internal medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Achen, S.E</au><au>Miller, M.W</au><au>Gordon, S.G</au><au>Saunders, A.B</au><au>Roland, R.M</au><au>Drourr, L.T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transarterial ductal occlusion with the amplatzer vascular plug in 31 dogs</atitle><jtitle>Journal of veterinary internal medicine</jtitle><addtitle>J Vet Intern Med</addtitle><date>2008-11</date><risdate>2008</risdate><volume>22</volume><issue>6</issue><spage>1348</spage><epage>1352</epage><pages>1348-1352</pages><issn>0891-6640</issn><eissn>1939-1676</eissn><abstract>Background: Transarterial ductal occlusion with the Amplatzer vascular plug was first reported in dogs by Hogan et al in 2005. Hypothesis: Use of the Amplatzer vascular plug is a safe, efficacious method of patent ductus arteriosus (PDA) occlusion. Animals: Thirty‐one client‐owned dogs with PDA. Methods: Records of 31 dogs in which transarterial occlusion of PDA with an Amplatzer vascular plug was attempted were reviewed. Results: All dogs had a type II PDA, with 27 dogs having type IIA morphology and 4 dogs having type IIB morphology. Appropriate device deployment was achieved in 29 of 31 dogs. Postdeployment angiography in 21 dogs documented complete occlusion in 10 dogs, trivial residual flow in 5 dogs, mild residual flow in 2 dogs, moderate residual flow in 3 dogs, and severe residual flow in 1 dog. Transthoracic color Doppler echocardiography documented complete occlusion in 22 dogs, whereas 2 dogs had trivial residual flow, 2 dogs had mild residual flow, 2 dogs had mild to moderate residual flow, and 1 dog had severe residual flow. Of the 7 dogs with residual flow, 2 had complete occlusion 2–4 months postoperatively, 1 had moderate residual flow 1 month postoperatively, and 4 were lost to follow‐up. One dog required a larger device than was able to be deployed through the largest sheath placed in the femoral artery. Pulmonary embolization of the device occurred in 1 dog. Conclusion: We conclude that ductal occlusion with an Amplatzer vascular plug is a safe and efficacious therapy for PDA in dogs.</abstract><cop>Malden, USA</cop><pub>Blackwell Publishing Inc</pub><pmid>18798793</pmid><doi>10.1111/j.1939-1676.2008.0185.x</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0891-6640
ispartof Journal of veterinary internal medicine, 2008-11, Vol.22 (6), p.1348-1352
issn 0891-6640
1939-1676
language eng
recordid cdi_proquest_miscellaneous_69790839
source Wiley-Blackwell Open Access Collection
subjects Animals
Cardiac Catheterization - instrumentation
Cardiac Catheterization - veterinary
Cardiac Surgical Procedures - instrumentation
Cardiac Surgical Procedures - veterinary
Congenital heart disease
Dog Diseases - surgery
Dogs
Ductus Arteriosus, Patent - surgery
Ductus Arteriosus, Patent - veterinary
Embolization, Therapeutic - instrumentation
Embolization, Therapeutic - veterinary
Equipment Design
heart diseases
PDA
Prostheses and Implants - veterinary
surgery
surgical equipment
title Transarterial ductal occlusion with the amplatzer vascular plug in 31 dogs
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T21%3A07%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_24P&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transarterial%20ductal%20occlusion%20with%20the%20amplatzer%20vascular%20plug%20in%2031%20dogs&rft.jtitle=Journal%20of%20veterinary%20internal%20medicine&rft.au=Achen,%20S.E&rft.date=2008-11&rft.volume=22&rft.issue=6&rft.spage=1348&rft.epage=1352&rft.pages=1348-1352&rft.issn=0891-6640&rft.eissn=1939-1676&rft_id=info:doi/10.1111/j.1939-1676.2008.0185.x&rft_dat=%3Cproquest_24P%3E69790839%3C/proquest_24P%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4755-863e4defe9cb069fb50bdfc9a55c1ff73e1a0f28fd5999a8154472148db3aff3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=69790839&rft_id=info:pmid/18798793&rfr_iscdi=true