Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients
We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of pro...
Saved in:
Published in: | European journal of nuclear medicine 1999-06, Vol.26 (6), p.606-614 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by 111In-biotin; imaging was acquired 30 min and 16-18 h after administration of 111In-biotin. Technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/111In-biotin scan was 97.7% (versus 88.9% for 99mTc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/111In-biotin scintigraphy was similar to that of 99mTc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/111In-biotin approach clearly performed better than 99mTc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for 99mTc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/111In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/111In-biotin scintigraphy were found versus 99mTc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators. |
---|---|
ISSN: | 0340-6997 1619-7070 1619-7089 |
DOI: | 10.1007/s002590050428 |