Loading…

Radiofrequency Catheter Ablation of Left Ventricular Outflow Tract Tachycardia from the Coronary Cusp: A New Approach to the Tachycardia Focus

Transcoronary Cusp Ablation of VT. Introduction: Idiopathic ventricular tachycardia (VT) originating from the left ventricular outflow tract (LVOT) is rare. Previously reported were two cases of LVOT tachycardia which were treated with radiofrequency (RF) catheter ablation through endocardial aortom...

Full description

Saved in:
Bibliographic Details
Published in:Journal of cardiovascular electrophysiology 1999-07, Vol.10 (7), p.1005-1009
Main Authors: SHIMOIKE, EIMEI, OHNISHI, YASUSHI, UEDA, NORIHIRO, MARUYAMA, TORU, KAJI, YOSHIKAZU
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4375-7d0f49c5c2dc63c723dd6e4563c2e75a46538e735042ce6bce388dd28aa538b23
cites cdi_FETCH-LOGICAL-c4375-7d0f49c5c2dc63c723dd6e4563c2e75a46538e735042ce6bce388dd28aa538b23
container_end_page 1009
container_issue 7
container_start_page 1005
container_title Journal of cardiovascular electrophysiology
container_volume 10
creator SHIMOIKE, EIMEI
OHNISHI, YASUSHI
UEDA, NORIHIRO
MARUYAMA, TORU
KAJI, YOSHIKAZU
description Transcoronary Cusp Ablation of VT. Introduction: Idiopathic ventricular tachycardia (VT) originating from the left ventricular outflow tract (LVOT) is rare. Previously reported were two cases of LVOT tachycardia which were treated with radiofrequency (RF) catheter ablation through endocardial aortomitral continuity. We report here a case of a repetitive LVOT tachycardia in which the QRS morphology during VT exhibited an atypical left bundle branch block and inferior axis. Pace mapping revealed that the origin of this VT was very close to the left sinus of Valsalva. Transcoronary cusp RF catheter ablation abolished the VT in this patient and is a new approach for the treatment of this kind of VT. The application of this approach to the other types of VT has yet to he determined.
doi_str_mv 10.1111/j.1540-8167.1999.tb01271.x
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69899086</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69899086</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4375-7d0f49c5c2dc63c723dd6e4563c2e75a46538e735042ce6bce388dd28aa538b23</originalsourceid><addsrcrecordid>eNqVUd1q2zAYFaNjydq9whC76J1dybJsOTcjmGZbCQuUbLdClj4TB8fKJJk0L9FnrrKE0tvqRh-cH-k7B6FvlKQ0nrttSnlOEkGLMqVVVaWhITQrafr0AU1foas4k5wnTJRsgj57vyWEsoLwT2gSAcqYIFP0_KhMZ1sH_0YY9BHXKmwggMPzplehswO2LV5CG_BfGILr9Ngrh1djaHt7wGundMBrpTdHrZzpFG6d3eFogWvr7KBcdBz9fobn-Dcc8Hy_dzaycbD_SW-VC6tHf4M-tqr38OVyX6M_i_t1_TNZrn78qufLROes5ElpSJtXmuvM6ILpMmPGFJDzOGdQcpUXnAkoGSd5pqFoNDAhjMmEUhFoMnaNbs--8T9xcx_krvMa-l4NYEcvi0pUFRFFJM7ORO2s9w5auXfdLu4lKZGnNuRWniKXp8jlqQ15aUM-RfHXyytjswPzRnqOPxK-nwmHrofjO6zlQ31PCeHsBZ2Lm_w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69899086</pqid></control><display><type>article</type><title>Radiofrequency Catheter Ablation of Left Ventricular Outflow Tract Tachycardia from the Coronary Cusp: A New Approach to the Tachycardia Focus</title><source>Wiley</source><creator>SHIMOIKE, EIMEI ; OHNISHI, YASUSHI ; UEDA, NORIHIRO ; MARUYAMA, TORU ; KAJI, YOSHIKAZU</creator><creatorcontrib>SHIMOIKE, EIMEI ; OHNISHI, YASUSHI ; UEDA, NORIHIRO ; MARUYAMA, TORU ; KAJI, YOSHIKAZU</creatorcontrib><description>Transcoronary Cusp Ablation of VT. Introduction: Idiopathic ventricular tachycardia (VT) originating from the left ventricular outflow tract (LVOT) is rare. Previously reported were two cases of LVOT tachycardia which were treated with radiofrequency (RF) catheter ablation through endocardial aortomitral continuity. We report here a case of a repetitive LVOT tachycardia in which the QRS morphology during VT exhibited an atypical left bundle branch block and inferior axis. Pace mapping revealed that the origin of this VT was very close to the left sinus of Valsalva. Transcoronary cusp RF catheter ablation abolished the VT in this patient and is a new approach for the treatment of this kind of VT. The application of this approach to the other types of VT has yet to he determined.</description><identifier>ISSN: 1045-3873</identifier><identifier>EISSN: 1540-8167</identifier><identifier>DOI: 10.1111/j.1540-8167.1999.tb01271.x</identifier><identifier>PMID: 10413380</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>Adult ; catheter ablation ; Catheter Ablation - methods ; Catheterization, Peripheral - methods ; Coronary Angiography ; coronary cusp ; Coronary Vessels ; Echocardiography ; Electrocardiography, Ambulatory ; Follow-Up Studies ; Humans ; left ventricular outflow tract ; Male ; radiofrequency ; Recurrence ; Tachycardia, Ventricular - diagnosis ; Tachycardia, Ventricular - physiopathology ; Tachycardia, Ventricular - surgery ; ventricular tachycardia</subject><ispartof>Journal of cardiovascular electrophysiology, 1999-07, Vol.10 (7), p.1005-1009</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4375-7d0f49c5c2dc63c723dd6e4563c2e75a46538e735042ce6bce388dd28aa538b23</citedby><cites>FETCH-LOGICAL-c4375-7d0f49c5c2dc63c723dd6e4563c2e75a46538e735042ce6bce388dd28aa538b23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10413380$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>SHIMOIKE, EIMEI</creatorcontrib><creatorcontrib>OHNISHI, YASUSHI</creatorcontrib><creatorcontrib>UEDA, NORIHIRO</creatorcontrib><creatorcontrib>MARUYAMA, TORU</creatorcontrib><creatorcontrib>KAJI, YOSHIKAZU</creatorcontrib><title>Radiofrequency Catheter Ablation of Left Ventricular Outflow Tract Tachycardia from the Coronary Cusp: A New Approach to the Tachycardia Focus</title><title>Journal of cardiovascular electrophysiology</title><addtitle>J Cardiovasc Electrophysiol</addtitle><description>Transcoronary Cusp Ablation of VT. Introduction: Idiopathic ventricular tachycardia (VT) originating from the left ventricular outflow tract (LVOT) is rare. Previously reported were two cases of LVOT tachycardia which were treated with radiofrequency (RF) catheter ablation through endocardial aortomitral continuity. We report here a case of a repetitive LVOT tachycardia in which the QRS morphology during VT exhibited an atypical left bundle branch block and inferior axis. Pace mapping revealed that the origin of this VT was very close to the left sinus of Valsalva. Transcoronary cusp RF catheter ablation abolished the VT in this patient and is a new approach for the treatment of this kind of VT. The application of this approach to the other types of VT has yet to he determined.</description><subject>Adult</subject><subject>catheter ablation</subject><subject>Catheter Ablation - methods</subject><subject>Catheterization, Peripheral - methods</subject><subject>Coronary Angiography</subject><subject>coronary cusp</subject><subject>Coronary Vessels</subject><subject>Echocardiography</subject><subject>Electrocardiography, Ambulatory</subject><subject>Follow-Up Studies</subject><subject>Humans</subject><subject>left ventricular outflow tract</subject><subject>Male</subject><subject>radiofrequency</subject><subject>Recurrence</subject><subject>Tachycardia, Ventricular - diagnosis</subject><subject>Tachycardia, Ventricular - physiopathology</subject><subject>Tachycardia, Ventricular - surgery</subject><subject>ventricular tachycardia</subject><issn>1045-3873</issn><issn>1540-8167</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNqVUd1q2zAYFaNjydq9whC76J1dybJsOTcjmGZbCQuUbLdClj4TB8fKJJk0L9FnrrKE0tvqRh-cH-k7B6FvlKQ0nrttSnlOEkGLMqVVVaWhITQrafr0AU1foas4k5wnTJRsgj57vyWEsoLwT2gSAcqYIFP0_KhMZ1sH_0YY9BHXKmwggMPzplehswO2LV5CG_BfGILr9Ngrh1djaHt7wGundMBrpTdHrZzpFG6d3eFogWvr7KBcdBz9fobn-Dcc8Hy_dzaycbD_SW-VC6tHf4M-tqr38OVyX6M_i_t1_TNZrn78qufLROes5ElpSJtXmuvM6ILpMmPGFJDzOGdQcpUXnAkoGSd5pqFoNDAhjMmEUhFoMnaNbs--8T9xcx_krvMa-l4NYEcvi0pUFRFFJM7ORO2s9w5auXfdLu4lKZGnNuRWniKXp8jlqQ15aUM-RfHXyytjswPzRnqOPxK-nwmHrofjO6zlQ31PCeHsBZ2Lm_w</recordid><startdate>199907</startdate><enddate>199907</enddate><creator>SHIMOIKE, EIMEI</creator><creator>OHNISHI, YASUSHI</creator><creator>UEDA, NORIHIRO</creator><creator>MARUYAMA, TORU</creator><creator>KAJI, YOSHIKAZU</creator><general>Blackwell Publishing Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199907</creationdate><title>Radiofrequency Catheter Ablation of Left Ventricular Outflow Tract Tachycardia from the Coronary Cusp: A New Approach to the Tachycardia Focus</title><author>SHIMOIKE, EIMEI ; OHNISHI, YASUSHI ; UEDA, NORIHIRO ; MARUYAMA, TORU ; KAJI, YOSHIKAZU</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4375-7d0f49c5c2dc63c723dd6e4563c2e75a46538e735042ce6bce388dd28aa538b23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Adult</topic><topic>catheter ablation</topic><topic>Catheter Ablation - methods</topic><topic>Catheterization, Peripheral - methods</topic><topic>Coronary Angiography</topic><topic>coronary cusp</topic><topic>Coronary Vessels</topic><topic>Echocardiography</topic><topic>Electrocardiography, Ambulatory</topic><topic>Follow-Up Studies</topic><topic>Humans</topic><topic>left ventricular outflow tract</topic><topic>Male</topic><topic>radiofrequency</topic><topic>Recurrence</topic><topic>Tachycardia, Ventricular - diagnosis</topic><topic>Tachycardia, Ventricular - physiopathology</topic><topic>Tachycardia, Ventricular - surgery</topic><topic>ventricular tachycardia</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>SHIMOIKE, EIMEI</creatorcontrib><creatorcontrib>OHNISHI, YASUSHI</creatorcontrib><creatorcontrib>UEDA, NORIHIRO</creatorcontrib><creatorcontrib>MARUYAMA, TORU</creatorcontrib><creatorcontrib>KAJI, YOSHIKAZU</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of cardiovascular electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SHIMOIKE, EIMEI</au><au>OHNISHI, YASUSHI</au><au>UEDA, NORIHIRO</au><au>MARUYAMA, TORU</au><au>KAJI, YOSHIKAZU</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radiofrequency Catheter Ablation of Left Ventricular Outflow Tract Tachycardia from the Coronary Cusp: A New Approach to the Tachycardia Focus</atitle><jtitle>Journal of cardiovascular electrophysiology</jtitle><addtitle>J Cardiovasc Electrophysiol</addtitle><date>1999-07</date><risdate>1999</risdate><volume>10</volume><issue>7</issue><spage>1005</spage><epage>1009</epage><pages>1005-1009</pages><issn>1045-3873</issn><eissn>1540-8167</eissn><abstract>Transcoronary Cusp Ablation of VT. Introduction: Idiopathic ventricular tachycardia (VT) originating from the left ventricular outflow tract (LVOT) is rare. Previously reported were two cases of LVOT tachycardia which were treated with radiofrequency (RF) catheter ablation through endocardial aortomitral continuity. We report here a case of a repetitive LVOT tachycardia in which the QRS morphology during VT exhibited an atypical left bundle branch block and inferior axis. Pace mapping revealed that the origin of this VT was very close to the left sinus of Valsalva. Transcoronary cusp RF catheter ablation abolished the VT in this patient and is a new approach for the treatment of this kind of VT. The application of this approach to the other types of VT has yet to he determined.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>10413380</pmid><doi>10.1111/j.1540-8167.1999.tb01271.x</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1045-3873
ispartof Journal of cardiovascular electrophysiology, 1999-07, Vol.10 (7), p.1005-1009
issn 1045-3873
1540-8167
language eng
recordid cdi_proquest_miscellaneous_69899086
source Wiley
subjects Adult
catheter ablation
Catheter Ablation - methods
Catheterization, Peripheral - methods
Coronary Angiography
coronary cusp
Coronary Vessels
Echocardiography
Electrocardiography, Ambulatory
Follow-Up Studies
Humans
left ventricular outflow tract
Male
radiofrequency
Recurrence
Tachycardia, Ventricular - diagnosis
Tachycardia, Ventricular - physiopathology
Tachycardia, Ventricular - surgery
ventricular tachycardia
title Radiofrequency Catheter Ablation of Left Ventricular Outflow Tract Tachycardia from the Coronary Cusp: A New Approach to the Tachycardia Focus
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T02%3A49%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radiofrequency%20Catheter%20Ablation%20of%20Left%20Ventricular%20Outflow%20Tract%20Tachycardia%20from%20the%20Coronary%20Cusp:%20A%20New%20Approach%20to%20the%20Tachycardia%20Focus&rft.jtitle=Journal%20of%20cardiovascular%20electrophysiology&rft.au=SHIMOIKE,%20EIMEI&rft.date=1999-07&rft.volume=10&rft.issue=7&rft.spage=1005&rft.epage=1009&rft.pages=1005-1009&rft.issn=1045-3873&rft.eissn=1540-8167&rft_id=info:doi/10.1111/j.1540-8167.1999.tb01271.x&rft_dat=%3Cproquest_cross%3E69899086%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4375-7d0f49c5c2dc63c723dd6e4563c2e75a46538e735042ce6bce388dd28aa538b23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=69899086&rft_id=info:pmid/10413380&rfr_iscdi=true