Loading…
Refractory post-transplant airway strictures: successful management with wire stents
Objective: Bronchial stenosis, malacia and dehiscence are major airway complications of lung transplantation. Our success in managing this problem evolved from the use of semi-rigid dilators, to balloon dilation and placement of a stent, which were initially silicone, thereafter wire balloon-expanda...
Saved in:
Published in: | European journal of cardio-thoracic surgery 1999-06, Vol.15 (6), p.842-850 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objective: Bronchial stenosis, malacia and dehiscence are major airway complications of lung transplantation. Our success in managing this problem evolved from the use of semi-rigid dilators, to balloon dilation and placement of a stent, which were initially silicone, thereafter wire balloon-expandable and finally wire self-expandable. Methods: From May, 1994 until July 1997, we performed a total of 49 single and 58 bilateral lung transplants. Symptoms of shortness of breath, verified by a drop in the forced expiratory volume in one second (FEV1), led to bronchoscopic inspection of the airway in lung transplant patients. Eighteen patients (16%) suffered a severe form of airway complication (dehiscence or stenosis) in 24 of 151 airways at risk (15.9%). These anastomotic strictures were recalcitrant to conventional therapy. Intervention consisted of rigid bronchoscopy, dilation of the stricture and placement of a stent. Flexible bronchoscopy and fluoroscopy were used for precise placement of the stent. As the initial stent, the Hood silicone stent was placed five times in four patients and the Dumont studded stent five times in four patients. The Palmaz wire stent was used as the initial stent 10 times in seven patients and the Wallstent used eight times in seven patients. Four patients had multiple stents. Balloon inflation moulded the wire stent to the airway. Results: There was no mortality resulting from the airway complication or any intervention. The most serious complication was a perforation of the airway using the semi-rigid dilator that necessitated immediate thoracotomy and re-anastomosis of the bronchus. Other complications necessitated repeat interventions due to restenosis or failure of the stents. The success of the stent placement was measured subjectively by the immediate ease of breathing enjoyed by each patient and objectively by the significant increase of the FEV1 from a pre-operative mean of 1.19 l (SD 0.64 l) to a post-operative mean of 2.06 l (SD 0.70 l) (P |
---|---|
ISSN: | 1010-7940 1873-734X |
DOI: | 10.1016/S1010-7940(99)00091-3 |