Loading…

Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis

The suitability of a long-range transmitter was evaluated for use with a Polhemus Fastrak ® magnetic tracking device in kinesiologic studies. Performance was judged by comparing positional and rotational accuracy to a standard transmitter. Data were obtained at distances of up to 2.7 and 5.0 m for t...

Full description

Saved in:
Bibliographic Details
Published in:Journal of biomechanics 1998-10, Vol.31 (10), p.957-961
Main Authors: Day, Judd S, Dumas, Genevieve A, Murdoch, Duncan J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c391t-8a85282a66fb61cc4c34d108dcdfce060a1d991b5c6fac3e33f1175dd70d18273
cites cdi_FETCH-LOGICAL-c391t-8a85282a66fb61cc4c34d108dcdfce060a1d991b5c6fac3e33f1175dd70d18273
container_end_page 961
container_issue 10
container_start_page 957
container_title Journal of biomechanics
container_volume 31
creator Day, Judd S
Dumas, Genevieve A
Murdoch, Duncan J
description The suitability of a long-range transmitter was evaluated for use with a Polhemus Fastrak ® magnetic tracking device in kinesiologic studies. Performance was judged by comparing positional and rotational accuracy to a standard transmitter. Data were obtained at distances of up to 2.7 and 5.0 m for the standard and long-range transmitters, respectively. Use of the long-range transmitter improved system performance allowing reproducible measurements at a greater distance. However, it is necessary to calibrate the system in each new test environment as there can be significant distortion of the magnetic field.
doi_str_mv 10.1016/S0021-9290(98)00089-X
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70080650</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S002192909800089X</els_id><sourcerecordid>70080650</sourcerecordid><originalsourceid>FETCH-LOGICAL-c391t-8a85282a66fb61cc4c34d108dcdfce060a1d991b5c6fac3e33f1175dd70d18273</originalsourceid><addsrcrecordid>eNqFkc1rFTEUxYMo9bX6JxSyEl2MvZnM5GMlUqoVCl1YobuQl9x5RmeSmmSe9L_vvA-67eouzu-cC-cQcs7gMwMmLn4CtKzRrYaPWn0CAKWb-1dkxZTkTcsVvCarZ-QtOS3lzwLJTuoTcqJVB1LwFbFXWzvOtoYUaRqopWOKmybbuEFal1OmUCtmOqRM54L0f6i_F2qym4g1uB3j_oa4oR63wSENkU5pn2ajHR9LKO_Im8GOBd8f7xn59e3q7vK6ubn9_uPy603juGa1UVb1rWqtEMNaMOc6xzvPQHnnB4cgwDKvNVv3TgzWceR8YEz23kvwTLWSn5EPh9yHnP7NWKqZQnE4jjZimouRS0MgengRbBnXUoluAfsD6HIqJeNgHnKYbH40DMxuA7PfwOwKNlqZ_QbmfvGdHx_M6wn9s-tY-qJ_Oei41LENmE1xAaNDHzK6anwKL3x4AsPql3Y</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21397864</pqid></control><display><type>article</type><title>Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis</title><source>ScienceDirect Freedom Collection</source><creator>Day, Judd S ; Dumas, Genevieve A ; Murdoch, Duncan J</creator><creatorcontrib>Day, Judd S ; Dumas, Genevieve A ; Murdoch, Duncan J</creatorcontrib><description>The suitability of a long-range transmitter was evaluated for use with a Polhemus Fastrak ® magnetic tracking device in kinesiologic studies. Performance was judged by comparing positional and rotational accuracy to a standard transmitter. Data were obtained at distances of up to 2.7 and 5.0 m for the standard and long-range transmitters, respectively. Use of the long-range transmitter improved system performance allowing reproducible measurements at a greater distance. However, it is necessary to calibrate the system in each new test environment as there can be significant distortion of the magnetic field.</description><identifier>ISSN: 0021-9290</identifier><identifier>EISSN: 1873-2380</identifier><identifier>DOI: 10.1016/S0021-9290(98)00089-X</identifier><identifier>PMID: 9840763</identifier><language>eng</language><publisher>United States: Elsevier Ltd</publisher><subject>Accuracy ; Equipment Design ; Error ; Evaluation Studies as Topic ; Humans ; Kinematic ; Kinematics ; Kinesiology, Applied - instrumentation ; Magnetic devices ; Magnetic tracking device ; Magnetics - instrumentation ; Measurement errors ; Motion ; Three-dimensional</subject><ispartof>Journal of biomechanics, 1998-10, Vol.31 (10), p.957-961</ispartof><rights>1998 Elsevier Science Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c391t-8a85282a66fb61cc4c34d108dcdfce060a1d991b5c6fac3e33f1175dd70d18273</citedby><cites>FETCH-LOGICAL-c391t-8a85282a66fb61cc4c34d108dcdfce060a1d991b5c6fac3e33f1175dd70d18273</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9840763$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Day, Judd S</creatorcontrib><creatorcontrib>Dumas, Genevieve A</creatorcontrib><creatorcontrib>Murdoch, Duncan J</creatorcontrib><title>Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis</title><title>Journal of biomechanics</title><addtitle>J Biomech</addtitle><description>The suitability of a long-range transmitter was evaluated for use with a Polhemus Fastrak ® magnetic tracking device in kinesiologic studies. Performance was judged by comparing positional and rotational accuracy to a standard transmitter. Data were obtained at distances of up to 2.7 and 5.0 m for the standard and long-range transmitters, respectively. Use of the long-range transmitter improved system performance allowing reproducible measurements at a greater distance. However, it is necessary to calibrate the system in each new test environment as there can be significant distortion of the magnetic field.</description><subject>Accuracy</subject><subject>Equipment Design</subject><subject>Error</subject><subject>Evaluation Studies as Topic</subject><subject>Humans</subject><subject>Kinematic</subject><subject>Kinematics</subject><subject>Kinesiology, Applied - instrumentation</subject><subject>Magnetic devices</subject><subject>Magnetic tracking device</subject><subject>Magnetics - instrumentation</subject><subject>Measurement errors</subject><subject>Motion</subject><subject>Three-dimensional</subject><issn>0021-9290</issn><issn>1873-2380</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkc1rFTEUxYMo9bX6JxSyEl2MvZnM5GMlUqoVCl1YobuQl9x5RmeSmmSe9L_vvA-67eouzu-cC-cQcs7gMwMmLn4CtKzRrYaPWn0CAKWb-1dkxZTkTcsVvCarZ-QtOS3lzwLJTuoTcqJVB1LwFbFXWzvOtoYUaRqopWOKmybbuEFal1OmUCtmOqRM54L0f6i_F2qym4g1uB3j_oa4oR63wSENkU5pn2ajHR9LKO_Im8GOBd8f7xn59e3q7vK6ubn9_uPy603juGa1UVb1rWqtEMNaMOc6xzvPQHnnB4cgwDKvNVv3TgzWceR8YEz23kvwTLWSn5EPh9yHnP7NWKqZQnE4jjZimouRS0MgengRbBnXUoluAfsD6HIqJeNgHnKYbH40DMxuA7PfwOwKNlqZ_QbmfvGdHx_M6wn9s-tY-qJ_Oei41LENmE1xAaNDHzK6anwKL3x4AsPql3Y</recordid><startdate>19981001</startdate><enddate>19981001</enddate><creator>Day, Judd S</creator><creator>Dumas, Genevieve A</creator><creator>Murdoch, Duncan J</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19981001</creationdate><title>Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis</title><author>Day, Judd S ; Dumas, Genevieve A ; Murdoch, Duncan J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c391t-8a85282a66fb61cc4c34d108dcdfce060a1d991b5c6fac3e33f1175dd70d18273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Accuracy</topic><topic>Equipment Design</topic><topic>Error</topic><topic>Evaluation Studies as Topic</topic><topic>Humans</topic><topic>Kinematic</topic><topic>Kinematics</topic><topic>Kinesiology, Applied - instrumentation</topic><topic>Magnetic devices</topic><topic>Magnetic tracking device</topic><topic>Magnetics - instrumentation</topic><topic>Measurement errors</topic><topic>Motion</topic><topic>Three-dimensional</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Day, Judd S</creatorcontrib><creatorcontrib>Dumas, Genevieve A</creatorcontrib><creatorcontrib>Murdoch, Duncan J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biomechanics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Day, Judd S</au><au>Dumas, Genevieve A</au><au>Murdoch, Duncan J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis</atitle><jtitle>Journal of biomechanics</jtitle><addtitle>J Biomech</addtitle><date>1998-10-01</date><risdate>1998</risdate><volume>31</volume><issue>10</issue><spage>957</spage><epage>961</epage><pages>957-961</pages><issn>0021-9290</issn><eissn>1873-2380</eissn><abstract>The suitability of a long-range transmitter was evaluated for use with a Polhemus Fastrak ® magnetic tracking device in kinesiologic studies. Performance was judged by comparing positional and rotational accuracy to a standard transmitter. Data were obtained at distances of up to 2.7 and 5.0 m for the standard and long-range transmitters, respectively. Use of the long-range transmitter improved system performance allowing reproducible measurements at a greater distance. However, it is necessary to calibrate the system in each new test environment as there can be significant distortion of the magnetic field.</abstract><cop>United States</cop><pub>Elsevier Ltd</pub><pmid>9840763</pmid><doi>10.1016/S0021-9290(98)00089-X</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9290
ispartof Journal of biomechanics, 1998-10, Vol.31 (10), p.957-961
issn 0021-9290
1873-2380
language eng
recordid cdi_proquest_miscellaneous_70080650
source ScienceDirect Freedom Collection
subjects Accuracy
Equipment Design
Error
Evaluation Studies as Topic
Humans
Kinematic
Kinematics
Kinesiology, Applied - instrumentation
Magnetic devices
Magnetic tracking device
Magnetics - instrumentation
Measurement errors
Motion
Three-dimensional
title Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T16%3A09%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20a%20long-range%20transmitter%20for%20use%20with%20a%20magnetic%20tracking%20device%20in%20motion%20analysis&rft.jtitle=Journal%20of%20biomechanics&rft.au=Day,%20Judd%20S&rft.date=1998-10-01&rft.volume=31&rft.issue=10&rft.spage=957&rft.epage=961&rft.pages=957-961&rft.issn=0021-9290&rft.eissn=1873-2380&rft_id=info:doi/10.1016/S0021-9290(98)00089-X&rft_dat=%3Cproquest_cross%3E70080650%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c391t-8a85282a66fb61cc4c34d108dcdfce060a1d991b5c6fac3e33f1175dd70d18273%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=21397864&rft_id=info:pmid/9840763&rfr_iscdi=true