Loading…

A bad day for quality control: sequential misplacement of left arm and left leg electrodes

Saved in:
Bibliographic Details
Published in:Journal of electrocardiology 2008, Vol.41 (1), p.1-3
Main Author: Greenfield, Joseph C., MD
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c460t-dd037d2d006f9d1e3f8e6510ea9a2691771a4d37c7456f70bb8cda7f3fc09b0c3
cites cdi_FETCH-LOGICAL-c460t-dd037d2d006f9d1e3f8e6510ea9a2691771a4d37c7456f70bb8cda7f3fc09b0c3
container_end_page 3
container_issue 1
container_start_page 1
container_title Journal of electrocardiology
container_volume 41
creator Greenfield, Joseph C., MD
description
doi_str_mv 10.1016/j.jelectrocard.2007.07.017
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70202634</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0022073607006899</els_id><sourcerecordid>1435824181</sourcerecordid><originalsourceid>FETCH-LOGICAL-c460t-dd037d2d006f9d1e3f8e6510ea9a2691771a4d37c7456f70bb8cda7f3fc09b0c3</originalsourceid><addsrcrecordid>eNqNkk-LFDEQxYMo7rj6FSTswVuPlaS7070HYVn_woIH9eIlpJOKpE13ZpNuYb69aWZQ2ZNQEApevXr5UYRcMdgzYO3rcT9iQLOkaHSyew4g91sx-YjsWCN41dUCHpMdAOcVSNFekGc5jwDQc8mfkgsmJZedlDvy_YYO2lKrj9TFRO9XHfxypCbOxT5c04z3K86L14FOPh-CNjiVnkZHA7qF6jRRPdtTE_AHPSezmJ-TJ06HjC_O7yX59v7d19uP1d3nD59ub-4qU7ewVNaCkJZbgNb1lqFwHbYNA9S95m1fojJdWyGNrJvWSRiGzlgtnXAG-gGMuCSvTr6HFEvYvKiS1GAIesa4ZiWBA29FXYRXD4RjXNNcsinOWg5900ARXZ9EJsWcEzp1SH7S6agYqA2_GtW_-NWGX23FZBl-ed6wDhPav6Nn3kXw9iTAAuSXx6Sy8TgbtD4VS2Wj_789bx7YmOBnb3T4iUfMf77FVOYK1JftELY7AFkod30vfgMFC7H7</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>216209550</pqid></control><display><type>article</type><title>A bad day for quality control: sequential misplacement of left arm and left leg electrodes</title><source>Elsevier ScienceDirect Freedom Collection 2023</source><creator>Greenfield, Joseph C., MD</creator><creatorcontrib>Greenfield, Joseph C., MD</creatorcontrib><identifier>ISSN: 0022-0736</identifier><identifier>EISSN: 1532-8430</identifier><identifier>DOI: 10.1016/j.jelectrocard.2007.07.017</identifier><identifier>PMID: 17727877</identifier><identifier>CODEN: JECAB4</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Arm ; Cardiovascular ; Clinical Competence ; Diagnostic Errors - prevention &amp; control ; Electrocardiography - instrumentation ; Electrodes ; Humans ; Leg ; Male ; Middle Aged ; Myocardial Infarction - diagnosis ; Quality Assurance, Health Care ; Quality Control</subject><ispartof>Journal of electrocardiology, 2008, Vol.41 (1), p.1-3</ispartof><rights>2008</rights><rights>Copyright Churchill Livingstone Inc., Medical Publishers Jan/Feb 2008</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c460t-dd037d2d006f9d1e3f8e6510ea9a2691771a4d37c7456f70bb8cda7f3fc09b0c3</citedby><cites>FETCH-LOGICAL-c460t-dd037d2d006f9d1e3f8e6510ea9a2691771a4d37c7456f70bb8cda7f3fc09b0c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17727877$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Greenfield, Joseph C., MD</creatorcontrib><title>A bad day for quality control: sequential misplacement of left arm and left leg electrodes</title><title>Journal of electrocardiology</title><addtitle>J Electrocardiol</addtitle><subject>Arm</subject><subject>Cardiovascular</subject><subject>Clinical Competence</subject><subject>Diagnostic Errors - prevention &amp; control</subject><subject>Electrocardiography - instrumentation</subject><subject>Electrodes</subject><subject>Humans</subject><subject>Leg</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Myocardial Infarction - diagnosis</subject><subject>Quality Assurance, Health Care</subject><subject>Quality Control</subject><issn>0022-0736</issn><issn>1532-8430</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqNkk-LFDEQxYMo7rj6FSTswVuPlaS7070HYVn_woIH9eIlpJOKpE13ZpNuYb69aWZQ2ZNQEApevXr5UYRcMdgzYO3rcT9iQLOkaHSyew4g91sx-YjsWCN41dUCHpMdAOcVSNFekGc5jwDQc8mfkgsmJZedlDvy_YYO2lKrj9TFRO9XHfxypCbOxT5c04z3K86L14FOPh-CNjiVnkZHA7qF6jRRPdtTE_AHPSezmJ-TJ06HjC_O7yX59v7d19uP1d3nD59ub-4qU7ewVNaCkJZbgNb1lqFwHbYNA9S95m1fojJdWyGNrJvWSRiGzlgtnXAG-gGMuCSvTr6HFEvYvKiS1GAIesa4ZiWBA29FXYRXD4RjXNNcsinOWg5900ARXZ9EJsWcEzp1SH7S6agYqA2_GtW_-NWGX23FZBl-ed6wDhPav6Nn3kXw9iTAAuSXx6Sy8TgbtD4VS2Wj_789bx7YmOBnb3T4iUfMf77FVOYK1JftELY7AFkod30vfgMFC7H7</recordid><startdate>2008</startdate><enddate>2008</enddate><creator>Greenfield, Joseph C., MD</creator><general>Elsevier Inc</general><general>Elsevier Science Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>88I</scope><scope>8AF</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>PHGZM</scope><scope>PHGZT</scope><scope>PJZUB</scope><scope>PKEHL</scope><scope>PPXIY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>S0X</scope><scope>7X8</scope></search><sort><creationdate>2008</creationdate><title>A bad day for quality control: sequential misplacement of left arm and left leg electrodes</title><author>Greenfield, Joseph C., MD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c460t-dd037d2d006f9d1e3f8e6510ea9a2691771a4d37c7456f70bb8cda7f3fc09b0c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Arm</topic><topic>Cardiovascular</topic><topic>Clinical Competence</topic><topic>Diagnostic Errors - prevention &amp; control</topic><topic>Electrocardiography - instrumentation</topic><topic>Electrodes</topic><topic>Humans</topic><topic>Leg</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Myocardial Infarction - diagnosis</topic><topic>Quality Assurance, Health Care</topic><topic>Quality Control</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Greenfield, Joseph C., MD</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>STEM Database</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Science Database</collection><collection>ProQuest Central (New)</collection><collection>ProQuest One Academic (New)</collection><collection>ProQuest Health &amp; Medical Research Collection</collection><collection>ProQuest One Academic Middle East (New)</collection><collection>ProQuest One Health &amp; Nursing</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>SIRS Editorial</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of electrocardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Greenfield, Joseph C., MD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A bad day for quality control: sequential misplacement of left arm and left leg electrodes</atitle><jtitle>Journal of electrocardiology</jtitle><addtitle>J Electrocardiol</addtitle><date>2008</date><risdate>2008</risdate><volume>41</volume><issue>1</issue><spage>1</spage><epage>3</epage><pages>1-3</pages><issn>0022-0736</issn><eissn>1532-8430</eissn><coden>JECAB4</coden><cop>United States</cop><pub>Elsevier Inc</pub><pmid>17727877</pmid><doi>10.1016/j.jelectrocard.2007.07.017</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-0736
ispartof Journal of electrocardiology, 2008, Vol.41 (1), p.1-3
issn 0022-0736
1532-8430
language eng
recordid cdi_proquest_miscellaneous_70202634
source Elsevier ScienceDirect Freedom Collection 2023
subjects Arm
Cardiovascular
Clinical Competence
Diagnostic Errors - prevention & control
Electrocardiography - instrumentation
Electrodes
Humans
Leg
Male
Middle Aged
Myocardial Infarction - diagnosis
Quality Assurance, Health Care
Quality Control
title A bad day for quality control: sequential misplacement of left arm and left leg electrodes
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-03-09T06%3A13%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20bad%20day%20for%20quality%20control:%20sequential%20misplacement%20of%20left%20arm%20and%20left%20leg%20electrodes&rft.jtitle=Journal%20of%20electrocardiology&rft.au=Greenfield,%20Joseph%20C.,%20MD&rft.date=2008&rft.volume=41&rft.issue=1&rft.spage=1&rft.epage=3&rft.pages=1-3&rft.issn=0022-0736&rft.eissn=1532-8430&rft.coden=JECAB4&rft_id=info:doi/10.1016/j.jelectrocard.2007.07.017&rft_dat=%3Cproquest_cross%3E1435824181%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c460t-dd037d2d006f9d1e3f8e6510ea9a2691771a4d37c7456f70bb8cda7f3fc09b0c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=216209550&rft_id=info:pmid/17727877&rfr_iscdi=true