Loading…
Determining the quantity and character of carotid artery embolic debris by electron microscopy and energy dispersive spectroscopy
Objectives Carotid artery angioplasty and stenting (CAS) is now routinely performed with embolic protection devices, yet little is known about the compositional characteristics of the captured embolic debris and whether the type or quantity of debris correlates with patient, lesion, or operator char...
Saved in:
Published in: | Journal of vascular surgery 2007-04, Vol.45 (4), p.716-725 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objectives Carotid artery angioplasty and stenting (CAS) is now routinely performed with embolic protection devices, yet little is known about the compositional characteristics of the captured embolic debris and whether the type or quantity of debris correlates with patient, lesion, or operator characteristics. This study examined the embolic debris generated during CAS using electron microscopy and energy dispersive spectroscopy (EDS) for symptomatic and asymptomatic patients. Methods Between 2003 and 2005, CAS for carotid stenosis was performed in 175 patients. Cerebral protection devices were used in all but three cases. Sixty-four consecutive unselected microporous filters from procedures performed by a single vascular surgeon were obtained for analysis. Captured particulate debris within the protection devices was quantified (number and mean size of particles) by light microscopy for all filters. Twenty protection devices (9 symptomatic, 11 asymptomatic patients) were processed for electron microscopy and EDS to assess morphology, cellular composition, and calcium content of debris. Results Captured particulate matter was present in 49 filters (77%) and included particles measuring 200 to 500 μm in 72%, 500 to 1000 μm in 53%, and >1000 μm in 33%. The mean number of captured particles was 6.9, and mean size was 248 ± 150 μm. Univariate analysis revealed that sequential patient cohort and filter type were correlated with the number (but not size) of captured particles. The number of particles significantly decreased after the first cohort of 20 patients (11.5 particles) compared with the second (5.0 particles, P = .023) and third (5.2 particles, P = .029) cohorts. The type of captured debris ranged from sheets of damaged red blood cells without other components to clumps of recently activated platelets with early fibrin crosslinking to plaque debris coated with well-organized coalescing areas of platelet thrombus. Platelet activation was more common in symptomatic patients (78%) than asymptomatic patients (27%; P < .05). Despite the presence of calcified lesions in six patients whose filters were analyzed by EDS, 1000 μm in one third of patients. The number of particles may decrease with in |
---|---|
ISSN: | 0741-5214 1097-6809 |
DOI: | 10.1016/j.jvs.2006.12.015 |