Radio frequency coil technology for small-animal MRI
A review of the theory, technology, and use of radio frequency (RF) coils for small‐animal MRI is presented. It includes a brief overview of MR signal‐to‐noise (S/N) analysis and discussions of the various coils commonly used in small‐animal MR: surface coils, linear volume coils, birdcages, and the...
Saved in:
Published in: | NMR in biomedicine 2007-05, Vol.20 (3), p.304-325 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c4229-af5dab1fd0b491df359023b07f4dcb5c1162397b5357400b87cb6d5838b52f4a3 |
---|---|
cites | cdi_FETCH-LOGICAL-c4229-af5dab1fd0b491df359023b07f4dcb5c1162397b5357400b87cb6d5838b52f4a3 |
container_end_page | 325 |
container_issue | 3 |
container_start_page | 304 |
container_title | NMR in biomedicine |
container_volume | 20 |
creator | Doty, F. David Entzminger, George Kulkarni, Jatin Pamarthy, Kranti Staab, John P. |
description | A review of the theory, technology, and use of radio frequency (RF) coils for small‐animal MRI is presented. It includes a brief overview of MR signal‐to‐noise (S/N) analysis and discussions of the various coils commonly used in small‐animal MR: surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid‐range coils, i.e. coils where the product (fd) of the frequency f and the coil diameter d is in the range 2–30 MHz‐m. Common applications include mouse brain and body coils from 125 to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full‐wave 3D electromagnetics software, and new simulation results are presented for a selection of surface coils using Microwave Studio 2006 by Computer Simulation Technology, showing the dramatic importance of the ‘lift‐off effect’. Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra‐low‐noise preamps based on the enhancement‐mode pseudomorphic high‐electron‐mobility transistor for optimal coil decoupling in phased arrays. Cryogenically cooled RF coils are shown to offer considerable opportunity for future gains in S/N in smaller samples. Copyright © 2007 John Wiley & Sons, Ltd. |
doi_str_mv | 10.1002/nbm.1149 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70451988</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70451988</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4229-af5dab1fd0b491df359023b07f4dcb5c1162397b5357400b87cb6d5838b52f4a3</originalsourceid><addsrcrecordid>eNqF0E1LxDAQBuAgiq4f4C-QnsRLdfLVNkdXdF1wV5BVwUtI0kSr3WZtdtH-eyNb9CSeZg4PLzMvQocYTjEAOWv0_BRjJjbQAIMQaVzJJhqA4CSlrIAdtBvCKwAUjJJttINzxjEuYIDYnSorn7jWvq9sY7rE-KpOlta8NL72z13ifJuEuarrVDVVnMnkbryPtpyqgz3o5x66v7qcXVynN7ej8cX5TWoYISJVjpdKY1eCZgKXjnIBhGrIHSuN5gbjjFCRa055zgB0kRudlbyghebEMUX30PE6d9H6eF5YynkVjK1r1Vi_CjKH-IYoin8hwZBlGYgIT9bQtD6E1jq5aONXbScxyO8qZaxSflcZ6VGfudJzW_7CvrsI0jX4qGrb_Rkkp8NJH9j7Kizt549X7ZvMcppz-TgdySnJrmfD2ZN8oF_07Yo_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21066609</pqid></control><display><type>article</type><title>Radio frequency coil technology for small-animal MRI</title><source>Wiley</source><creator>Doty, F. David ; Entzminger, George ; Kulkarni, Jatin ; Pamarthy, Kranti ; Staab, John P.</creator><creatorcontrib>Doty, F. David ; Entzminger, George ; Kulkarni, Jatin ; Pamarthy, Kranti ; Staab, John P.</creatorcontrib><description>A review of the theory, technology, and use of radio frequency (RF) coils for small‐animal MRI is presented. It includes a brief overview of MR signal‐to‐noise (S/N) analysis and discussions of the various coils commonly used in small‐animal MR: surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid‐range coils, i.e. coils where the product (fd) of the frequency f and the coil diameter d is in the range 2–30 MHz‐m. Common applications include mouse brain and body coils from 125 to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full‐wave 3D electromagnetics software, and new simulation results are presented for a selection of surface coils using Microwave Studio 2006 by Computer Simulation Technology, showing the dramatic importance of the ‘lift‐off effect’. Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra‐low‐noise preamps based on the enhancement‐mode pseudomorphic high‐electron‐mobility transistor for optimal coil decoupling in phased arrays. Cryogenically cooled RF coils are shown to offer considerable opportunity for future gains in S/N in smaller samples. Copyright © 2007 John Wiley & Sons, Ltd.</description><identifier>ISSN: 0952-3480</identifier><identifier>EISSN: 1099-1492</identifier><identifier>DOI: 10.1002/nbm.1149</identifier><identifier>PMID: 17451180</identifier><language>eng</language><publisher>Chichester, UK: John Wiley & Sons, Ltd</publisher><subject>Animals ; Brain - diagnostic imaging ; circular polarization volume coils ; decoupling ; Electric Capacitance ; Electric Conductivity ; Embryo, Mammalian - diagnostic imaging ; low-noise preamplifiers ; Magnetic Resonance Imaging - instrumentation ; Magnetic Resonance Imaging - methods ; Mice ; Models, Theoretical ; phased arrays ; Radio Waves ; Radiography ; Rats ; small-animal MRI ; surface coils</subject><ispartof>NMR in biomedicine, 2007-05, Vol.20 (3), p.304-325</ispartof><rights>Copyright © 2007 John Wiley & Sons, Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4229-af5dab1fd0b491df359023b07f4dcb5c1162397b5357400b87cb6d5838b52f4a3</citedby><cites>FETCH-LOGICAL-c4229-af5dab1fd0b491df359023b07f4dcb5c1162397b5357400b87cb6d5838b52f4a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17451180$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Doty, F. David</creatorcontrib><creatorcontrib>Entzminger, George</creatorcontrib><creatorcontrib>Kulkarni, Jatin</creatorcontrib><creatorcontrib>Pamarthy, Kranti</creatorcontrib><creatorcontrib>Staab, John P.</creatorcontrib><title>Radio frequency coil technology for small-animal MRI</title><title>NMR in biomedicine</title><addtitle>NMR Biomed</addtitle><description>A review of the theory, technology, and use of radio frequency (RF) coils for small‐animal MRI is presented. It includes a brief overview of MR signal‐to‐noise (S/N) analysis and discussions of the various coils commonly used in small‐animal MR: surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid‐range coils, i.e. coils where the product (fd) of the frequency f and the coil diameter d is in the range 2–30 MHz‐m. Common applications include mouse brain and body coils from 125 to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full‐wave 3D electromagnetics software, and new simulation results are presented for a selection of surface coils using Microwave Studio 2006 by Computer Simulation Technology, showing the dramatic importance of the ‘lift‐off effect’. Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra‐low‐noise preamps based on the enhancement‐mode pseudomorphic high‐electron‐mobility transistor for optimal coil decoupling in phased arrays. Cryogenically cooled RF coils are shown to offer considerable opportunity for future gains in S/N in smaller samples. Copyright © 2007 John Wiley & Sons, Ltd.</description><subject>Animals</subject><subject>Brain - diagnostic imaging</subject><subject>circular polarization volume coils</subject><subject>decoupling</subject><subject>Electric Capacitance</subject><subject>Electric Conductivity</subject><subject>Embryo, Mammalian - diagnostic imaging</subject><subject>low-noise preamplifiers</subject><subject>Magnetic Resonance Imaging - instrumentation</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Mice</subject><subject>Models, Theoretical</subject><subject>phased arrays</subject><subject>Radio Waves</subject><subject>Radiography</subject><subject>Rats</subject><subject>small-animal MRI</subject><subject>surface coils</subject><issn>0952-3480</issn><issn>1099-1492</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqF0E1LxDAQBuAgiq4f4C-QnsRLdfLVNkdXdF1wV5BVwUtI0kSr3WZtdtH-eyNb9CSeZg4PLzMvQocYTjEAOWv0_BRjJjbQAIMQaVzJJhqA4CSlrIAdtBvCKwAUjJJttINzxjEuYIDYnSorn7jWvq9sY7rE-KpOlta8NL72z13ifJuEuarrVDVVnMnkbryPtpyqgz3o5x66v7qcXVynN7ej8cX5TWoYISJVjpdKY1eCZgKXjnIBhGrIHSuN5gbjjFCRa055zgB0kRudlbyghebEMUX30PE6d9H6eF5YynkVjK1r1Vi_CjKH-IYoin8hwZBlGYgIT9bQtD6E1jq5aONXbScxyO8qZaxSflcZ6VGfudJzW_7CvrsI0jX4qGrb_Rkkp8NJH9j7Kizt549X7ZvMcppz-TgdySnJrmfD2ZN8oF_07Yo_</recordid><startdate>200705</startdate><enddate>200705</enddate><creator>Doty, F. David</creator><creator>Entzminger, George</creator><creator>Kulkarni, Jatin</creator><creator>Pamarthy, Kranti</creator><creator>Staab, John P.</creator><general>John Wiley & Sons, Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>200705</creationdate><title>Radio frequency coil technology for small-animal MRI</title><author>Doty, F. David ; Entzminger, George ; Kulkarni, Jatin ; Pamarthy, Kranti ; Staab, John P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4229-af5dab1fd0b491df359023b07f4dcb5c1162397b5357400b87cb6d5838b52f4a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Animals</topic><topic>Brain - diagnostic imaging</topic><topic>circular polarization volume coils</topic><topic>decoupling</topic><topic>Electric Capacitance</topic><topic>Electric Conductivity</topic><topic>Embryo, Mammalian - diagnostic imaging</topic><topic>low-noise preamplifiers</topic><topic>Magnetic Resonance Imaging - instrumentation</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Mice</topic><topic>Models, Theoretical</topic><topic>phased arrays</topic><topic>Radio Waves</topic><topic>Radiography</topic><topic>Rats</topic><topic>small-animal MRI</topic><topic>surface coils</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Doty, F. David</creatorcontrib><creatorcontrib>Entzminger, George</creatorcontrib><creatorcontrib>Kulkarni, Jatin</creatorcontrib><creatorcontrib>Pamarthy, Kranti</creatorcontrib><creatorcontrib>Staab, John P.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>NMR in biomedicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Doty, F. David</au><au>Entzminger, George</au><au>Kulkarni, Jatin</au><au>Pamarthy, Kranti</au><au>Staab, John P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radio frequency coil technology for small-animal MRI</atitle><jtitle>NMR in biomedicine</jtitle><addtitle>NMR Biomed</addtitle><date>2007-05</date><risdate>2007</risdate><volume>20</volume><issue>3</issue><spage>304</spage><epage>325</epage><pages>304-325</pages><issn>0952-3480</issn><eissn>1099-1492</eissn><abstract>A review of the theory, technology, and use of radio frequency (RF) coils for small‐animal MRI is presented. It includes a brief overview of MR signal‐to‐noise (S/N) analysis and discussions of the various coils commonly used in small‐animal MR: surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid‐range coils, i.e. coils where the product (fd) of the frequency f and the coil diameter d is in the range 2–30 MHz‐m. Common applications include mouse brain and body coils from 125 to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full‐wave 3D electromagnetics software, and new simulation results are presented for a selection of surface coils using Microwave Studio 2006 by Computer Simulation Technology, showing the dramatic importance of the ‘lift‐off effect’. Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra‐low‐noise preamps based on the enhancement‐mode pseudomorphic high‐electron‐mobility transistor for optimal coil decoupling in phased arrays. Cryogenically cooled RF coils are shown to offer considerable opportunity for future gains in S/N in smaller samples. Copyright © 2007 John Wiley & Sons, Ltd.</abstract><cop>Chichester, UK</cop><pub>John Wiley & Sons, Ltd</pub><pmid>17451180</pmid><doi>10.1002/nbm.1149</doi><tpages>22</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0952-3480 |
ispartof | NMR in biomedicine, 2007-05, Vol.20 (3), p.304-325 |
issn | 0952-3480 1099-1492 |
language | eng |
recordid | cdi_proquest_miscellaneous_70451988 |
source | Wiley |
subjects | Animals Brain - diagnostic imaging circular polarization volume coils decoupling Electric Capacitance Electric Conductivity Embryo, Mammalian - diagnostic imaging low-noise preamplifiers Magnetic Resonance Imaging - instrumentation Magnetic Resonance Imaging - methods Mice Models, Theoretical phased arrays Radio Waves Radiography Rats small-animal MRI surface coils |
title | Radio frequency coil technology for small-animal MRI |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T19%3A31%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radio%20frequency%20coil%20technology%20for%20small-animal%20MRI&rft.jtitle=NMR%20in%20biomedicine&rft.au=Doty,%20F.%20David&rft.date=2007-05&rft.volume=20&rft.issue=3&rft.spage=304&rft.epage=325&rft.pages=304-325&rft.issn=0952-3480&rft.eissn=1099-1492&rft_id=info:doi/10.1002/nbm.1149&rft_dat=%3Cproquest_cross%3E70451988%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4229-af5dab1fd0b491df359023b07f4dcb5c1162397b5357400b87cb6d5838b52f4a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=21066609&rft_id=info:pmid/17451180&rfr_iscdi=true |