Loading…

Detector effects in photothermal deflection experiments

We report on the theoretical analysis of a detector type influence on the normal deflection signal in photothermal experiments. Two cases are examined. In the first, the quadrant photodiode was considered as the detector; in the second the signal from the position detector, which measures the centra...

Full description

Saved in:
Bibliographic Details
Published in:Applied optics (2004) 2008-04, Vol.47 (10), p.1559-1566
Main Authors: Kobylińska, Dorota Korte, Bukowski, Roman J, Bodzenia, Jerzy, Kochowski, Stanisław, Kazmiercźak-Balata, Anna
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We report on the theoretical analysis of a detector type influence on the normal deflection signal in photothermal experiments. Two cases are examined. In the first, the quadrant photodiode was considered as the detector; in the second the signal from the position detector, which measures the central moment displacement of the probe beam, was analyzed. Both analyses were carried out within the framework of the complex ray theory. The normal photodeflection signal was found to depend on the type of detector used in the photothermal deflection experiments for some parameters of its setup.
ISSN:1559-128X
DOI:10.1364/AO.47.001559