Loading…

Sensitive detection of plasma/serum DNA in patients with systemic lupus erythematosus

Objective: To optimize the use of the fluorochromic PicoGreen assay for the sensitive detection and quantification of double stranded (ds) DNA in plasma/serum samples of patients with systemic lupus erythematosus (SLE). Methods: Plasma/serum samples were obtained from SLE patients and normal healthy...

Full description

Saved in:
Bibliographic Details
Published in:Autoimmunity (Chur, Switzerland) Switzerland), 2007-06, Vol.40 (4), p.307-310
Main Authors: Chen, Justin A., Meister, Silke, Urbonaviciute, Vilma, Rödel, Franz, Wilhelm, Sabine, Kalden, Joachim R., Manger, Karin, Voll, Reinhard E.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c340t-a36856672f85644d683e6513b56a1998175394b270b638ae820462b6c62504a53
cites
container_end_page 310
container_issue 4
container_start_page 307
container_title Autoimmunity (Chur, Switzerland)
container_volume 40
creator Chen, Justin A.
Meister, Silke
Urbonaviciute, Vilma
Rödel, Franz
Wilhelm, Sabine
Kalden, Joachim R.
Manger, Karin
Voll, Reinhard E.
description Objective: To optimize the use of the fluorochromic PicoGreen assay for the sensitive detection and quantification of double stranded (ds) DNA in plasma/serum samples of patients with systemic lupus erythematosus (SLE). Methods: Plasma/serum samples were obtained from SLE patients and normal healthy donors (NHD). Plasma/serum proteins were digested with proteinase K. DNA was subsequently purified using silica-based ion exchange micro columns and detected using the PicoGreen assay. Results: Sensitive detection of plasma/serum DNA is impaired by proteins: (1) Proteins caused background fluorescence in the PicoGreen assay. (2) Packaging of dsDNA in nucleosomes markedly reduced PicoGreen fluorescence. Therefore, we digested proteins using proteinase K and purified DNA before detection by PicoGreen assay. This procedure resulted in a detection limit for plasma/serum dsDNA of less than 1 ng/ml, and is therefore markedly more sensitive than previously described methods. We found that DNA concentrations are higher in serum than in plasma of healthy donors, suggesting artifactual DNA release during coagulation. In addition, we found higher levels of DNA in plasma and serum of a group of SLE patients compared to NHD. Conclusions: We have optimized the use of the PicoGreen assay for the ultrasensitive and reliable quantification of DNA in plasma/serum samples. This new method can be used in future studies to explore a possible correlation between circulating DNA levels and disease activity in patients with SLE.
doi_str_mv 10.1080/08916930701356317
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_70504581</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>19738754</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-a36856672f85644d683e6513b56a1998175394b270b638ae820462b6c62504a53</originalsourceid><addsrcrecordid>eNqF0TtPwzAQB3ALgWgpfAAW5Ikt1I6fEVNVnlIFA1Ris5z0orrKC9sB9duTqmViYLrhfjrd3R-hS0puKNFkSnRGZcaIIpQJyag6QmMqiUo0Tz-O0XjXTwbAR-gshA0hJFWSn6IRVYLKlMoxWr5BE1x0X4BXEKGIrm1wW-KusqG20wC-r_Hdywy7Bnc2OmhiwN8urnHYhgi1K3DVd33A4LdxDbWNbejDOTopbRXg4lAnaPlw_z5_Shavj8_z2SIpGCcxsUxqIaVKy6FwvpKagRSU5UJammV6WJNlPE8VySXTFnRKuExzWchUEG4Fm6Dr_dzOt589hGhqFwqoKttA2wejyOCEpv9CmimmleADvDrAPq9hZTrvauu35vdjA7jdA9eUra_tGmwV14X1YDZt75vhXEOJ2eVj_uTDfgCUo378</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19738754</pqid></control><display><type>article</type><title>Sensitive detection of plasma/serum DNA in patients with systemic lupus erythematosus</title><source>Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list)</source><creator>Chen, Justin A. ; Meister, Silke ; Urbonaviciute, Vilma ; Rödel, Franz ; Wilhelm, Sabine ; Kalden, Joachim R. ; Manger, Karin ; Voll, Reinhard E.</creator><creatorcontrib>Chen, Justin A. ; Meister, Silke ; Urbonaviciute, Vilma ; Rödel, Franz ; Wilhelm, Sabine ; Kalden, Joachim R. ; Manger, Karin ; Voll, Reinhard E.</creatorcontrib><description>Objective: To optimize the use of the fluorochromic PicoGreen assay for the sensitive detection and quantification of double stranded (ds) DNA in plasma/serum samples of patients with systemic lupus erythematosus (SLE). Methods: Plasma/serum samples were obtained from SLE patients and normal healthy donors (NHD). Plasma/serum proteins were digested with proteinase K. DNA was subsequently purified using silica-based ion exchange micro columns and detected using the PicoGreen assay. Results: Sensitive detection of plasma/serum DNA is impaired by proteins: (1) Proteins caused background fluorescence in the PicoGreen assay. (2) Packaging of dsDNA in nucleosomes markedly reduced PicoGreen fluorescence. Therefore, we digested proteins using proteinase K and purified DNA before detection by PicoGreen assay. This procedure resulted in a detection limit for plasma/serum dsDNA of less than 1 ng/ml, and is therefore markedly more sensitive than previously described methods. We found that DNA concentrations are higher in serum than in plasma of healthy donors, suggesting artifactual DNA release during coagulation. In addition, we found higher levels of DNA in plasma and serum of a group of SLE patients compared to NHD. Conclusions: We have optimized the use of the PicoGreen assay for the ultrasensitive and reliable quantification of DNA in plasma/serum samples. This new method can be used in future studies to explore a possible correlation between circulating DNA levels and disease activity in patients with SLE.</description><identifier>ISSN: 0891-6934</identifier><identifier>EISSN: 1607-842X</identifier><identifier>DOI: 10.1080/08916930701356317</identifier><identifier>PMID: 17516216</identifier><language>eng</language><publisher>England: Informa UK Ltd</publisher><subject>Blood Donors ; DNA - blood ; Female ; Humans ; Lupus Erythematosus, Systemic - blood ; Male ; Reagent Kits, Diagnostic ; Sensitivity and Specificity</subject><ispartof>Autoimmunity (Chur, Switzerland), 2007-06, Vol.40 (4), p.307-310</ispartof><rights>2007 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 2007</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c340t-a36856672f85644d683e6513b56a1998175394b270b638ae820462b6c62504a53</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27915,27916</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17516216$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, Justin A.</creatorcontrib><creatorcontrib>Meister, Silke</creatorcontrib><creatorcontrib>Urbonaviciute, Vilma</creatorcontrib><creatorcontrib>Rödel, Franz</creatorcontrib><creatorcontrib>Wilhelm, Sabine</creatorcontrib><creatorcontrib>Kalden, Joachim R.</creatorcontrib><creatorcontrib>Manger, Karin</creatorcontrib><creatorcontrib>Voll, Reinhard E.</creatorcontrib><title>Sensitive detection of plasma/serum DNA in patients with systemic lupus erythematosus</title><title>Autoimmunity (Chur, Switzerland)</title><addtitle>Autoimmunity</addtitle><description>Objective: To optimize the use of the fluorochromic PicoGreen assay for the sensitive detection and quantification of double stranded (ds) DNA in plasma/serum samples of patients with systemic lupus erythematosus (SLE). Methods: Plasma/serum samples were obtained from SLE patients and normal healthy donors (NHD). Plasma/serum proteins were digested with proteinase K. DNA was subsequently purified using silica-based ion exchange micro columns and detected using the PicoGreen assay. Results: Sensitive detection of plasma/serum DNA is impaired by proteins: (1) Proteins caused background fluorescence in the PicoGreen assay. (2) Packaging of dsDNA in nucleosomes markedly reduced PicoGreen fluorescence. Therefore, we digested proteins using proteinase K and purified DNA before detection by PicoGreen assay. This procedure resulted in a detection limit for plasma/serum dsDNA of less than 1 ng/ml, and is therefore markedly more sensitive than previously described methods. We found that DNA concentrations are higher in serum than in plasma of healthy donors, suggesting artifactual DNA release during coagulation. In addition, we found higher levels of DNA in plasma and serum of a group of SLE patients compared to NHD. Conclusions: We have optimized the use of the PicoGreen assay for the ultrasensitive and reliable quantification of DNA in plasma/serum samples. This new method can be used in future studies to explore a possible correlation between circulating DNA levels and disease activity in patients with SLE.</description><subject>Blood Donors</subject><subject>DNA - blood</subject><subject>Female</subject><subject>Humans</subject><subject>Lupus Erythematosus, Systemic - blood</subject><subject>Male</subject><subject>Reagent Kits, Diagnostic</subject><subject>Sensitivity and Specificity</subject><issn>0891-6934</issn><issn>1607-842X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqF0TtPwzAQB3ALgWgpfAAW5Ikt1I6fEVNVnlIFA1Ris5z0orrKC9sB9duTqmViYLrhfjrd3R-hS0puKNFkSnRGZcaIIpQJyag6QmMqiUo0Tz-O0XjXTwbAR-gshA0hJFWSn6IRVYLKlMoxWr5BE1x0X4BXEKGIrm1wW-KusqG20wC-r_Hdywy7Bnc2OmhiwN8urnHYhgi1K3DVd33A4LdxDbWNbejDOTopbRXg4lAnaPlw_z5_Shavj8_z2SIpGCcxsUxqIaVKy6FwvpKagRSU5UJammV6WJNlPE8VySXTFnRKuExzWchUEG4Fm6Dr_dzOt589hGhqFwqoKttA2wejyOCEpv9CmimmleADvDrAPq9hZTrvauu35vdjA7jdA9eUra_tGmwV14X1YDZt75vhXEOJ2eVj_uTDfgCUo378</recordid><startdate>200706</startdate><enddate>200706</enddate><creator>Chen, Justin A.</creator><creator>Meister, Silke</creator><creator>Urbonaviciute, Vilma</creator><creator>Rödel, Franz</creator><creator>Wilhelm, Sabine</creator><creator>Kalden, Joachim R.</creator><creator>Manger, Karin</creator><creator>Voll, Reinhard E.</creator><general>Informa UK Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7T5</scope><scope>7TM</scope><scope>H94</scope><scope>7X8</scope></search><sort><creationdate>200706</creationdate><title>Sensitive detection of plasma/serum DNA in patients with systemic lupus erythematosus</title><author>Chen, Justin A. ; Meister, Silke ; Urbonaviciute, Vilma ; Rödel, Franz ; Wilhelm, Sabine ; Kalden, Joachim R. ; Manger, Karin ; Voll, Reinhard E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-a36856672f85644d683e6513b56a1998175394b270b638ae820462b6c62504a53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Blood Donors</topic><topic>DNA - blood</topic><topic>Female</topic><topic>Humans</topic><topic>Lupus Erythematosus, Systemic - blood</topic><topic>Male</topic><topic>Reagent Kits, Diagnostic</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, Justin A.</creatorcontrib><creatorcontrib>Meister, Silke</creatorcontrib><creatorcontrib>Urbonaviciute, Vilma</creatorcontrib><creatorcontrib>Rödel, Franz</creatorcontrib><creatorcontrib>Wilhelm, Sabine</creatorcontrib><creatorcontrib>Kalden, Joachim R.</creatorcontrib><creatorcontrib>Manger, Karin</creatorcontrib><creatorcontrib>Voll, Reinhard E.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>Immunology Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Autoimmunity (Chur, Switzerland)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, Justin A.</au><au>Meister, Silke</au><au>Urbonaviciute, Vilma</au><au>Rödel, Franz</au><au>Wilhelm, Sabine</au><au>Kalden, Joachim R.</au><au>Manger, Karin</au><au>Voll, Reinhard E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitive detection of plasma/serum DNA in patients with systemic lupus erythematosus</atitle><jtitle>Autoimmunity (Chur, Switzerland)</jtitle><addtitle>Autoimmunity</addtitle><date>2007-06</date><risdate>2007</risdate><volume>40</volume><issue>4</issue><spage>307</spage><epage>310</epage><pages>307-310</pages><issn>0891-6934</issn><eissn>1607-842X</eissn><abstract>Objective: To optimize the use of the fluorochromic PicoGreen assay for the sensitive detection and quantification of double stranded (ds) DNA in plasma/serum samples of patients with systemic lupus erythematosus (SLE). Methods: Plasma/serum samples were obtained from SLE patients and normal healthy donors (NHD). Plasma/serum proteins were digested with proteinase K. DNA was subsequently purified using silica-based ion exchange micro columns and detected using the PicoGreen assay. Results: Sensitive detection of plasma/serum DNA is impaired by proteins: (1) Proteins caused background fluorescence in the PicoGreen assay. (2) Packaging of dsDNA in nucleosomes markedly reduced PicoGreen fluorescence. Therefore, we digested proteins using proteinase K and purified DNA before detection by PicoGreen assay. This procedure resulted in a detection limit for plasma/serum dsDNA of less than 1 ng/ml, and is therefore markedly more sensitive than previously described methods. We found that DNA concentrations are higher in serum than in plasma of healthy donors, suggesting artifactual DNA release during coagulation. In addition, we found higher levels of DNA in plasma and serum of a group of SLE patients compared to NHD. Conclusions: We have optimized the use of the PicoGreen assay for the ultrasensitive and reliable quantification of DNA in plasma/serum samples. This new method can be used in future studies to explore a possible correlation between circulating DNA levels and disease activity in patients with SLE.</abstract><cop>England</cop><pub>Informa UK Ltd</pub><pmid>17516216</pmid><doi>10.1080/08916930701356317</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0891-6934
ispartof Autoimmunity (Chur, Switzerland), 2007-06, Vol.40 (4), p.307-310
issn 0891-6934
1607-842X
language eng
recordid cdi_proquest_miscellaneous_70504581
source Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list)
subjects Blood Donors
DNA - blood
Female
Humans
Lupus Erythematosus, Systemic - blood
Male
Reagent Kits, Diagnostic
Sensitivity and Specificity
title Sensitive detection of plasma/serum DNA in patients with systemic lupus erythematosus
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T05%3A45%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitive%20detection%20of%20plasma/serum%20DNA%20in%20patients%20with%20systemic%20lupus%20erythematosus&rft.jtitle=Autoimmunity%20(Chur,%20Switzerland)&rft.au=Chen,%20Justin%20A.&rft.date=2007-06&rft.volume=40&rft.issue=4&rft.spage=307&rft.epage=310&rft.pages=307-310&rft.issn=0891-6934&rft.eissn=1607-842X&rft_id=info:doi/10.1080/08916930701356317&rft_dat=%3Cproquest_pubme%3E19738754%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c340t-a36856672f85644d683e6513b56a1998175394b270b638ae820462b6c62504a53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=19738754&rft_id=info:pmid/17516216&rfr_iscdi=true