Loading…

Accuracy of cervical assessment in the active phase of labour

Objective  To determine accuracy of clinicians in estimating cervical dilatation during the active phase of labour and how this is affected by clinician experience and obstetric factors. Design  Prospective, cross‐sectional, comparative study. Setting  Chris Hani Baragwanath Hospital labour ward, Jo...

Full description

Saved in:
Bibliographic Details
Published in:BJOG : an international journal of obstetrics and gynaecology 2007-07, Vol.114 (7), p.833-837
Main Authors: Buchmann, EJ, Libhaber, E
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective  To determine accuracy of clinicians in estimating cervical dilatation during the active phase of labour and how this is affected by clinician experience and obstetric factors. Design  Prospective, cross‐sectional, comparative study. Setting  Chris Hani Baragwanath Hospital labour ward, Johannesburg, South Africa. Population  Women at term in the active phase of labour, with vertex presentations and live fetuses. Methods  The researcher performed cervical assessment immediately after the clinician on duty. The researcher and clinician were unaware of each other’s findings. The researcher, used as the standard, was an experienced obstetric consultant, and the clinicians were hospital consultants and registrars at various levels of training. Accuracy was defined as agreement of the clinician’s cervical dilatation estimate with that of the researcher. Multivariate logistic regression analysis was carried out to determine independent predictors of inaccuracy. Main outcome measure  Agreement in estimation of cervical dilatation between the researcher and the clinicians. Results  Examinations were performed on 508 women. The researcher and clinicians agreed on the dilatation in 250 instances (49.2%) and differed by 2 cm or more in 56 (11.0%) (kappa = 0.40, 95% CI 0.34–0.45). Accuracy was greater at low (3–4 cm) and high (8–10 cm) dilatations. Reduced accuracy was associated with decreasing clinician experience and with lower stations of fetal head. Conclusion  This is the first study to investigate accuracy of cervical assessment in parturient women. Results were similar to those found in studies that used models, with about 90% of estimations accurate to within 1 cm.
ISSN:1470-0328
1471-0528
DOI:10.1111/j.1471-0528.2007.01386.x