Loading…
Three-dimensional visualization of lung blood flow heterogeneity based on fluorescent microsphere technique and fractal dimension: The Blood Flow Analysis System — BFA System
The heterogeneity of regional pulmonary blood flow (RPBF) can be assessed by fractal analysis. The fractal dimension (FD) is a scale-independent measure of spatial heterogeneity of blood flow. The relative dispersion (RD) is often used to obtain the heterogeneity of RPBF but it is influenced by the...
Saved in:
Published in: | Computer methods and programs in biomedicine 2001-04, Vol.65 (1), p.79-87 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c420t-726378e2fc35cb103b3faabd20a53a1e40e72f6b643e7af0616f1c4916e883a13 |
---|---|
cites | cdi_FETCH-LOGICAL-c420t-726378e2fc35cb103b3faabd20a53a1e40e72f6b643e7af0616f1c4916e883a13 |
container_end_page | 87 |
container_issue | 1 |
container_start_page | 79 |
container_title | Computer methods and programs in biomedicine |
container_volume | 65 |
creator | Bottino, D.A. Kleen, M. Kemming, G. Meisner, F. Habler, O. Messmer, K. |
description | The heterogeneity of regional pulmonary blood flow (RPBF) can be assessed by fractal analysis. The fractal dimension (FD) is a scale-independent measure of spatial heterogeneity of blood flow. The relative dispersion (RD) is often used to obtain the heterogeneity of RPBF but it is influenced by the resolution of measurement. The Blood Flow Analysis (BFA) System was developed in Delphi to represent the three-dimensional structure of lung blood flow and calculates statistics of FD, RD, spatial correlation of neighbored tissue samples and shows histograms of blood flows at diverse time points during different experiments. The BFA System reads a text file with flows, measured with fluorescent microsphere technique, and constructs the lung anatomy with volumetric pixels showing the flows with a color schema. It is possible to rotate the lungs into two axis (
XY) and the statistics are shown with 3D graphics. The System maintains a database with data from various studies at same time. The BFA System was validated with four data sets from previous experiments. The BFA System has shown consistency and it is a new tool to help researchers during lung perfusion studies. |
doi_str_mv | 10.1016/S0169-2607(00)00115-2 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70662329</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0169260700001152</els_id><sourcerecordid>18654363</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-726378e2fc35cb103b3faabd20a53a1e40e72f6b643e7af0616f1c4916e883a13</originalsourceid><addsrcrecordid>eNqFkU2O1DAQhSMEYpqBI4AsISFYBPwTO8lsUM-IBqSRWEyzthynMjFy4sZ2BjUrDsFBOBMnwemOmuVsbJX01atX9bLsOcFvCSbi3U166pwKXL7G-A3GhPCcPshWpCppXnLBH2arE3KWPQnhG8aYci4eZ2eEUMoIZ6vsz7b3AHlrBhiDcaOy6M6ESVnzU8VUI9chO423qLHOtaiz7gfqIYJ3tzCCiXvUqAAtSmRnJ-chaBgjGoz2Lux68IAi6H403ydAakwKXumYppwmXqBtD-jyIL-Z5dfJxD6YgG72IcKA_v76jS4366V8mj3qlA3wbPnPs6-bD9urT_n1l4-fr9bXuS4ojnlJBSsroJ1mXDcEs4Z1SjUtxYozRaDAUNJONKJgUKoOCyI6oouaCKiqBLDz7NVRd-dd8h6iHEzazVo1gpuCLLEQlNH6XpBUghdMsATyIzifJnjo5M6bQfm9JFjOmcpDpnIOTGIsD5lKmvpeLAOmZoD2f9cSYgJeLoAKWtl04VGbcOJqXItilnl_pCBd7c6Al0EbGDW0xoOOsnXmHiP_AGfcwYw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>18654363</pqid></control><display><type>article</type><title>Three-dimensional visualization of lung blood flow heterogeneity based on fluorescent microsphere technique and fractal dimension: The Blood Flow Analysis System — BFA System</title><source>Elsevier:Jisc Collections:Elsevier Read and Publish Agreement 2022-2024:Freedom Collection (Reading list)</source><creator>Bottino, D.A. ; Kleen, M. ; Kemming, G. ; Meisner, F. ; Habler, O. ; Messmer, K.</creator><creatorcontrib>Bottino, D.A. ; Kleen, M. ; Kemming, G. ; Meisner, F. ; Habler, O. ; Messmer, K.</creatorcontrib><description>The heterogeneity of regional pulmonary blood flow (RPBF) can be assessed by fractal analysis. The fractal dimension (FD) is a scale-independent measure of spatial heterogeneity of blood flow. The relative dispersion (RD) is often used to obtain the heterogeneity of RPBF but it is influenced by the resolution of measurement. The Blood Flow Analysis (BFA) System was developed in Delphi to represent the three-dimensional structure of lung blood flow and calculates statistics of FD, RD, spatial correlation of neighbored tissue samples and shows histograms of blood flows at diverse time points during different experiments. The BFA System reads a text file with flows, measured with fluorescent microsphere technique, and constructs the lung anatomy with volumetric pixels showing the flows with a color schema. It is possible to rotate the lungs into two axis (
XY) and the statistics are shown with 3D graphics. The System maintains a database with data from various studies at same time. The BFA System was validated with four data sets from previous experiments. The BFA System has shown consistency and it is a new tool to help researchers during lung perfusion studies.</description><identifier>ISSN: 0169-2607</identifier><identifier>EISSN: 1872-7565</identifier><identifier>DOI: 10.1016/S0169-2607(00)00115-2</identifier><identifier>PMID: 11223153</identifier><language>eng</language><publisher>Shannon: Elsevier Ireland Ltd</publisher><subject>3D lung reconstruction ; Animals ; Biological and medical sciences ; Fluorescent Dyes ; Fractal dimension ; Fractals ; Investigative techniques of hemodynamics ; Investigative techniques, diagnostic techniques (general aspects) ; Lung - anatomy & histology ; Lung - blood supply ; Medical sciences ; Microspheres ; Miscellaneous ; Models, Cardiovascular ; Pulmonary blood flow ; Pulmonary Circulation ; Regional Blood Flow ; Relative dispersion ; Software ; Spatial correlation</subject><ispartof>Computer methods and programs in biomedicine, 2001-04, Vol.65 (1), p.79-87</ispartof><rights>2001 Elsevier Science Ireland Ltd</rights><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c420t-726378e2fc35cb103b3faabd20a53a1e40e72f6b643e7af0616f1c4916e883a13</citedby><cites>FETCH-LOGICAL-c420t-726378e2fc35cb103b3faabd20a53a1e40e72f6b643e7af0616f1c4916e883a13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=909642$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11223153$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bottino, D.A.</creatorcontrib><creatorcontrib>Kleen, M.</creatorcontrib><creatorcontrib>Kemming, G.</creatorcontrib><creatorcontrib>Meisner, F.</creatorcontrib><creatorcontrib>Habler, O.</creatorcontrib><creatorcontrib>Messmer, K.</creatorcontrib><title>Three-dimensional visualization of lung blood flow heterogeneity based on fluorescent microsphere technique and fractal dimension: The Blood Flow Analysis System — BFA System</title><title>Computer methods and programs in biomedicine</title><addtitle>Comput Methods Programs Biomed</addtitle><description>The heterogeneity of regional pulmonary blood flow (RPBF) can be assessed by fractal analysis. The fractal dimension (FD) is a scale-independent measure of spatial heterogeneity of blood flow. The relative dispersion (RD) is often used to obtain the heterogeneity of RPBF but it is influenced by the resolution of measurement. The Blood Flow Analysis (BFA) System was developed in Delphi to represent the three-dimensional structure of lung blood flow and calculates statistics of FD, RD, spatial correlation of neighbored tissue samples and shows histograms of blood flows at diverse time points during different experiments. The BFA System reads a text file with flows, measured with fluorescent microsphere technique, and constructs the lung anatomy with volumetric pixels showing the flows with a color schema. It is possible to rotate the lungs into two axis (
XY) and the statistics are shown with 3D graphics. The System maintains a database with data from various studies at same time. The BFA System was validated with four data sets from previous experiments. The BFA System has shown consistency and it is a new tool to help researchers during lung perfusion studies.</description><subject>3D lung reconstruction</subject><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Fluorescent Dyes</subject><subject>Fractal dimension</subject><subject>Fractals</subject><subject>Investigative techniques of hemodynamics</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Lung - anatomy & histology</subject><subject>Lung - blood supply</subject><subject>Medical sciences</subject><subject>Microspheres</subject><subject>Miscellaneous</subject><subject>Models, Cardiovascular</subject><subject>Pulmonary blood flow</subject><subject>Pulmonary Circulation</subject><subject>Regional Blood Flow</subject><subject>Relative dispersion</subject><subject>Software</subject><subject>Spatial correlation</subject><issn>0169-2607</issn><issn>1872-7565</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNqFkU2O1DAQhSMEYpqBI4AsISFYBPwTO8lsUM-IBqSRWEyzthynMjFy4sZ2BjUrDsFBOBMnwemOmuVsbJX01atX9bLsOcFvCSbi3U166pwKXL7G-A3GhPCcPshWpCppXnLBH2arE3KWPQnhG8aYci4eZ2eEUMoIZ6vsz7b3AHlrBhiDcaOy6M6ESVnzU8VUI9chO423qLHOtaiz7gfqIYJ3tzCCiXvUqAAtSmRnJ-chaBgjGoz2Lux68IAi6H403ydAakwKXumYppwmXqBtD-jyIL-Z5dfJxD6YgG72IcKA_v76jS4366V8mj3qlA3wbPnPs6-bD9urT_n1l4-fr9bXuS4ojnlJBSsroJ1mXDcEs4Z1SjUtxYozRaDAUNJONKJgUKoOCyI6oouaCKiqBLDz7NVRd-dd8h6iHEzazVo1gpuCLLEQlNH6XpBUghdMsATyIzifJnjo5M6bQfm9JFjOmcpDpnIOTGIsD5lKmvpeLAOmZoD2f9cSYgJeLoAKWtl04VGbcOJqXItilnl_pCBd7c6Al0EbGDW0xoOOsnXmHiP_AGfcwYw</recordid><startdate>20010401</startdate><enddate>20010401</enddate><creator>Bottino, D.A.</creator><creator>Kleen, M.</creator><creator>Kemming, G.</creator><creator>Meisner, F.</creator><creator>Habler, O.</creator><creator>Messmer, K.</creator><general>Elsevier Ireland Ltd</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20010401</creationdate><title>Three-dimensional visualization of lung blood flow heterogeneity based on fluorescent microsphere technique and fractal dimension: The Blood Flow Analysis System — BFA System</title><author>Bottino, D.A. ; Kleen, M. ; Kemming, G. ; Meisner, F. ; Habler, O. ; Messmer, K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-726378e2fc35cb103b3faabd20a53a1e40e72f6b643e7af0616f1c4916e883a13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>3D lung reconstruction</topic><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Fluorescent Dyes</topic><topic>Fractal dimension</topic><topic>Fractals</topic><topic>Investigative techniques of hemodynamics</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Lung - anatomy & histology</topic><topic>Lung - blood supply</topic><topic>Medical sciences</topic><topic>Microspheres</topic><topic>Miscellaneous</topic><topic>Models, Cardiovascular</topic><topic>Pulmonary blood flow</topic><topic>Pulmonary Circulation</topic><topic>Regional Blood Flow</topic><topic>Relative dispersion</topic><topic>Software</topic><topic>Spatial correlation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bottino, D.A.</creatorcontrib><creatorcontrib>Kleen, M.</creatorcontrib><creatorcontrib>Kemming, G.</creatorcontrib><creatorcontrib>Meisner, F.</creatorcontrib><creatorcontrib>Habler, O.</creatorcontrib><creatorcontrib>Messmer, K.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Computer methods and programs in biomedicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bottino, D.A.</au><au>Kleen, M.</au><au>Kemming, G.</au><au>Meisner, F.</au><au>Habler, O.</au><au>Messmer, K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Three-dimensional visualization of lung blood flow heterogeneity based on fluorescent microsphere technique and fractal dimension: The Blood Flow Analysis System — BFA System</atitle><jtitle>Computer methods and programs in biomedicine</jtitle><addtitle>Comput Methods Programs Biomed</addtitle><date>2001-04-01</date><risdate>2001</risdate><volume>65</volume><issue>1</issue><spage>79</spage><epage>87</epage><pages>79-87</pages><issn>0169-2607</issn><eissn>1872-7565</eissn><abstract>The heterogeneity of regional pulmonary blood flow (RPBF) can be assessed by fractal analysis. The fractal dimension (FD) is a scale-independent measure of spatial heterogeneity of blood flow. The relative dispersion (RD) is often used to obtain the heterogeneity of RPBF but it is influenced by the resolution of measurement. The Blood Flow Analysis (BFA) System was developed in Delphi to represent the three-dimensional structure of lung blood flow and calculates statistics of FD, RD, spatial correlation of neighbored tissue samples and shows histograms of blood flows at diverse time points during different experiments. The BFA System reads a text file with flows, measured with fluorescent microsphere technique, and constructs the lung anatomy with volumetric pixels showing the flows with a color schema. It is possible to rotate the lungs into two axis (
XY) and the statistics are shown with 3D graphics. The System maintains a database with data from various studies at same time. The BFA System was validated with four data sets from previous experiments. The BFA System has shown consistency and it is a new tool to help researchers during lung perfusion studies.</abstract><cop>Shannon</cop><pub>Elsevier Ireland Ltd</pub><pmid>11223153</pmid><doi>10.1016/S0169-2607(00)00115-2</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0169-2607 |
ispartof | Computer methods and programs in biomedicine, 2001-04, Vol.65 (1), p.79-87 |
issn | 0169-2607 1872-7565 |
language | eng |
recordid | cdi_proquest_miscellaneous_70662329 |
source | Elsevier:Jisc Collections:Elsevier Read and Publish Agreement 2022-2024:Freedom Collection (Reading list) |
subjects | 3D lung reconstruction Animals Biological and medical sciences Fluorescent Dyes Fractal dimension Fractals Investigative techniques of hemodynamics Investigative techniques, diagnostic techniques (general aspects) Lung - anatomy & histology Lung - blood supply Medical sciences Microspheres Miscellaneous Models, Cardiovascular Pulmonary blood flow Pulmonary Circulation Regional Blood Flow Relative dispersion Software Spatial correlation |
title | Three-dimensional visualization of lung blood flow heterogeneity based on fluorescent microsphere technique and fractal dimension: The Blood Flow Analysis System — BFA System |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T09%3A24%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Three-dimensional%20visualization%20of%20lung%20blood%20flow%20heterogeneity%20based%20on%20fluorescent%20microsphere%20technique%20and%20fractal%20dimension:%20The%20Blood%20Flow%20Analysis%20System%20%E2%80%94%20BFA%20System&rft.jtitle=Computer%20methods%20and%20programs%20in%20biomedicine&rft.au=Bottino,%20D.A.&rft.date=2001-04-01&rft.volume=65&rft.issue=1&rft.spage=79&rft.epage=87&rft.pages=79-87&rft.issn=0169-2607&rft.eissn=1872-7565&rft_id=info:doi/10.1016/S0169-2607(00)00115-2&rft_dat=%3Cproquest_cross%3E18654363%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c420t-726378e2fc35cb103b3faabd20a53a1e40e72f6b643e7af0616f1c4916e883a13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=18654363&rft_id=info:pmid/11223153&rfr_iscdi=true |