Loading…

A new technique of direct intra-abdominal pressure measurement: A preliminary study

The purpose of this study was to determine if a 14-F polyvinyl chloride (PVC) round drain is a reliable tool for direct intra-abdominal pressure measurement. A prospective interventional study. Department of Surgery B, intensive care unit, recovery room, Hillel-Yaffe level II trauma center. Forty pa...

Full description

Saved in:
Bibliographic Details
Published in:The American journal of surgery 2006-02, Vol.191 (2), p.235-237
Main Authors: Risin, Elena, Kessel, Boris, Ashkenazi, Itamar, Lieberman, Noah, Alfici, Ricardo
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The purpose of this study was to determine if a 14-F polyvinyl chloride (PVC) round drain is a reliable tool for direct intra-abdominal pressure measurement. A prospective interventional study. Department of Surgery B, intensive care unit, recovery room, Hillel-Yaffe level II trauma center. Forty patients undergoing abdominal surgery and treated postoperatively with intraperitoneal drains and intravesical catheters were included in this study. The indication for insertion of intraperitoneal drains and intravesical catheters was strictly medical. The decision of placing urinary bladder catheter and PVC round drain was done by a senior surgeon. Intra-abdominal pressures were measured simultaneously through the intraperitoneal drain and the urinary catheter. Using a sterile technique, the intraperitoneal drain was disconnected from the drainage bulb and connected to an invasive blood pressure monitoring system. Intravesical pressures were measured by inserting 50 mL into the bladder, and then the urinary catheter was connected to an invasive blood monitoring system. Measurements were done twice a day for 3 days or less if earlier removal of either the intraperitoneal drain or urinary catheters were medically indicated. Two hundred twenty-even simultaneous measurements were performed. Pressures as measured through the intraperitoneal drain were found to be significantly correlated to pressures as measured intravesically ( r = 0.962). Direct measurement of the intra-abdominal pressure via a 14-F PVC round drain is a newly described technique. Our method is simple, safe, and credible. Future investigation is needed to confirm the reliability of this method for continuous postoperative measurement of the intra-abdominal pressure in selected patients.
ISSN:0002-9610
1879-1883
DOI:10.1016/j.amjsurg.2005.07.038