Interobserver and intraobserver reproducibility of peripheral blood and oxygen pressure measurements in the assessment of lower extremity arterial disease

Introduction: Peripheral blood pressure measurements play a prominent role in the diagnosis and follow-up of patients with peripheral vascular diseases. Toe pressure of the hallux (TP1) and second toe (TP2) and transcutaneous oxygen pressure (TCPO2) measurements are becoming more important. The ankl...

Full description

Saved in:
Bibliographic Details
Published in:Journal of vascular surgery 2001-05, Vol.33 (5), p.1033-1040
Main Authors: de Graaff, Jurgen C., Ubbink, Dirk Th, Legemate, Dink A., de Haan, Rob J., Jacobs, Michael J.H.M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction: Peripheral blood pressure measurements play a prominent role in the diagnosis and follow-up of patients with peripheral vascular diseases. Toe pressure of the hallux (TP1) and second toe (TP2) and transcutaneous oxygen pressure (TCPO2) measurements are becoming more important. The ankle/brachial pressure index (ABPI) is known to be a reliable parameter, but the toe pressure and TCPO2 are evaluated less thoroughly. Therefore, we evaluated the reproducibility of TP1, TP2, TCPO2, ABPI, ankle pressure (AP), and brachial pressure (BP). Patients and Methods: In 54 patients with various stages of peripheral vascular disease, the intraobserver and interobserver reproducibility of BP, AP, ABPI, TP1, TP2, and TCPO2 was investigated by calculating the repeatability coefficient (RC) and the intraclass correlation coefficient (ICC) and by using Bland-Altman plots. Results: The intraobserver and interobserver reproducibility at 1 day and after 1 week of BP, AP, ABPI, and TP1 was substantial and comparable (ICC range, 0.80-0.99), except for the BP after 1 week. The TP2 and TCPO2 were less reproducible (ICC range, 0.62-0.98). The interobserver RC of BP was 31 mm Hg; of AP, 44 mm Hg; of ABPI, 27%; of TP1, 41 mm Hg; of TP2, 67 mm Hg; and of TCPO2; 30 mm Hg. The difference plot showed that the observer variability was equally distributed across the range of pressure in all measurements. Conclusion: The BP, AP, ABPI, and TP1 have a substantial intraobserver and interobserver reproducibility, whereas TP2 and TCPO2 show worse reproducibility. Especially when low values (or values around a cutoff value) are measured, the RC should be taken into account, and repetition of the measurement is advocated. (J Vasc Surg 2001;33:1033-40.)
ISSN:0741-5214
1097-6809