Loading…
Opacification of the urinary tract in portal venous spiral CT without delayed scans
In portal venous spiral CT there is no visible renal contrast excretion within the usual period of scanning. To opacify collecting systems additional delayed scanning is required. We administered an extra pre-dose of contrast medium before the main portal venous bolus in order to opacify the urinary...
Saved in:
Published in: | European radiology 1999-01, Vol.9 (8), p.1579-1585 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c316t-98f646a80189749d5cd872873c46dd5a8cd8bfec074a0edea2ffe5dbd67a56743 |
---|---|
cites | |
container_end_page | 1585 |
container_issue | 8 |
container_start_page | 1579 |
container_title | European radiology |
container_volume | 9 |
creator | Dinkel, H Moll, R Fieger, M Knüpffer, J Schindler, G |
description | In portal venous spiral CT there is no visible renal contrast excretion within the usual period of scanning. To opacify collecting systems additional delayed scanning is required. We administered an extra pre-dose of contrast medium before the main portal venous bolus in order to opacify the urinary tract and studied its effects on liver attenuation. In 32 patients examined first by non-contrast spiral CT 20 ml of a non-ionic IV CM were injected. Five minutes later, orientating cuts in the liver and along the urinary tract were obtained. Immediately thereafter, a 120-ml bolus was administered at 3 ml/s for portal venous phase helical CT (60-s delay craniocaudad). The quality of renal excretion was graded visually (excellent, fair, poor, none). Hepatic attenuation measurements were performed at comparable regions of interest. In all patients 20 ml CM opacified the renal pelvis after 5 min. Depiction of the ureters was excellent in 14, fair in 11 and poor or none in 7 cases. There was little effect on mean hepatic attenuation by the 20-ml pre-bolus after 5 min: mean enhancement 2.3 HU (range -0.6 to 7.8 HU). Mean hepatic enhancement after the 120-ml portal venous bolus ranged between 23.6 and 74.1 HU (mean 51.5 HU). When opacification of the urinary tract is necessary, pre-administration of a 20-ml bolus 5 min before portal venous scanning may save an extra delayed spiral. The effects on hepatic enhancement are negligible. |
doi_str_mv | 10.1007/s003300050888 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70858403</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2431580891</sourcerecordid><originalsourceid>FETCH-LOGICAL-c316t-98f646a80189749d5cd872873c46dd5a8cd8bfec074a0edea2ffe5dbd67a56743</originalsourceid><addsrcrecordid>eNpdkM9LwzAcxYMoOqdHrxI8eKt-0yZNcpThLxjs4DyXLElZRtfUJFX23xvZDurp8eDD4_FB6IrAHQHg9xGgqgCAgRDiCE0IrcqCgKDHaAKyEgWXkp6h8xg3mZKE8lN0RoCVTNRygt4Wg9KudVol53vsW5zWFo_B9SrscApKJ-x6PPiQVIc_be_HiOPgQm6zJf5yae3HhI3t1M4aHLXq4wU6aVUX7eUhp-j96XE5eynmi-fX2cO80BWpUyFFW9NaCSBCcioN00bwUvBK09oYpkTuq9Zq4FSBNVaVbWuZWZmaK1ZzWk3R7X53CP5jtDE1Wxe17TrV23yz4SCYoFnPFN38Azd-DH3-1ghBmawpZRkq9pAOPsZg22YIbpstNASaH9XNH9WZvz6MjqutNb_ovdvqG2bZeSk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>884596445</pqid></control><display><type>article</type><title>Opacification of the urinary tract in portal venous spiral CT without delayed scans</title><source>Springer Link</source><creator>Dinkel, H ; Moll, R ; Fieger, M ; Knüpffer, J ; Schindler, G</creator><creatorcontrib>Dinkel, H ; Moll, R ; Fieger, M ; Knüpffer, J ; Schindler, G</creatorcontrib><description>In portal venous spiral CT there is no visible renal contrast excretion within the usual period of scanning. To opacify collecting systems additional delayed scanning is required. We administered an extra pre-dose of contrast medium before the main portal venous bolus in order to opacify the urinary tract and studied its effects on liver attenuation. In 32 patients examined first by non-contrast spiral CT 20 ml of a non-ionic IV CM were injected. Five minutes later, orientating cuts in the liver and along the urinary tract were obtained. Immediately thereafter, a 120-ml bolus was administered at 3 ml/s for portal venous phase helical CT (60-s delay craniocaudad). The quality of renal excretion was graded visually (excellent, fair, poor, none). Hepatic attenuation measurements were performed at comparable regions of interest. In all patients 20 ml CM opacified the renal pelvis after 5 min. Depiction of the ureters was excellent in 14, fair in 11 and poor or none in 7 cases. There was little effect on mean hepatic attenuation by the 20-ml pre-bolus after 5 min: mean enhancement 2.3 HU (range -0.6 to 7.8 HU). Mean hepatic enhancement after the 120-ml portal venous bolus ranged between 23.6 and 74.1 HU (mean 51.5 HU). When opacification of the urinary tract is necessary, pre-administration of a 20-ml bolus 5 min before portal venous scanning may save an extra delayed spiral. The effects on hepatic enhancement are negligible.</description><identifier>ISSN: 0938-7994</identifier><identifier>EISSN: 1432-1084</identifier><identifier>DOI: 10.1007/s003300050888</identifier><identifier>PMID: 10525869</identifier><language>eng</language><publisher>Germany: Springer Nature B.V</publisher><subject>Contrast Media - administration & dosage ; Humans ; Iopamidol ; Kidney - diagnostic imaging ; Liver - diagnostic imaging ; Lung cancer ; Male ; Middle Aged ; Portal Vein - diagnostic imaging ; Prospective Studies ; Time Factors ; Tomography, X-Ray Computed - methods ; Ureter - diagnostic imaging ; Urogenital system</subject><ispartof>European radiology, 1999-01, Vol.9 (8), p.1579-1585</ispartof><rights>Springer-Verlag Berlin Heidelberg 1999</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c316t-98f646a80189749d5cd872873c46dd5a8cd8bfec074a0edea2ffe5dbd67a56743</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10525869$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dinkel, H</creatorcontrib><creatorcontrib>Moll, R</creatorcontrib><creatorcontrib>Fieger, M</creatorcontrib><creatorcontrib>Knüpffer, J</creatorcontrib><creatorcontrib>Schindler, G</creatorcontrib><title>Opacification of the urinary tract in portal venous spiral CT without delayed scans</title><title>European radiology</title><addtitle>Eur Radiol</addtitle><description>In portal venous spiral CT there is no visible renal contrast excretion within the usual period of scanning. To opacify collecting systems additional delayed scanning is required. We administered an extra pre-dose of contrast medium before the main portal venous bolus in order to opacify the urinary tract and studied its effects on liver attenuation. In 32 patients examined first by non-contrast spiral CT 20 ml of a non-ionic IV CM were injected. Five minutes later, orientating cuts in the liver and along the urinary tract were obtained. Immediately thereafter, a 120-ml bolus was administered at 3 ml/s for portal venous phase helical CT (60-s delay craniocaudad). The quality of renal excretion was graded visually (excellent, fair, poor, none). Hepatic attenuation measurements were performed at comparable regions of interest. In all patients 20 ml CM opacified the renal pelvis after 5 min. Depiction of the ureters was excellent in 14, fair in 11 and poor or none in 7 cases. There was little effect on mean hepatic attenuation by the 20-ml pre-bolus after 5 min: mean enhancement 2.3 HU (range -0.6 to 7.8 HU). Mean hepatic enhancement after the 120-ml portal venous bolus ranged between 23.6 and 74.1 HU (mean 51.5 HU). When opacification of the urinary tract is necessary, pre-administration of a 20-ml bolus 5 min before portal venous scanning may save an extra delayed spiral. The effects on hepatic enhancement are negligible.</description><subject>Contrast Media - administration & dosage</subject><subject>Humans</subject><subject>Iopamidol</subject><subject>Kidney - diagnostic imaging</subject><subject>Liver - diagnostic imaging</subject><subject>Lung cancer</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Portal Vein - diagnostic imaging</subject><subject>Prospective Studies</subject><subject>Time Factors</subject><subject>Tomography, X-Ray Computed - methods</subject><subject>Ureter - diagnostic imaging</subject><subject>Urogenital system</subject><issn>0938-7994</issn><issn>1432-1084</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNpdkM9LwzAcxYMoOqdHrxI8eKt-0yZNcpThLxjs4DyXLElZRtfUJFX23xvZDurp8eDD4_FB6IrAHQHg9xGgqgCAgRDiCE0IrcqCgKDHaAKyEgWXkp6h8xg3mZKE8lN0RoCVTNRygt4Wg9KudVol53vsW5zWFo_B9SrscApKJ-x6PPiQVIc_be_HiOPgQm6zJf5yae3HhI3t1M4aHLXq4wU6aVUX7eUhp-j96XE5eynmi-fX2cO80BWpUyFFW9NaCSBCcioN00bwUvBK09oYpkTuq9Zq4FSBNVaVbWuZWZmaK1ZzWk3R7X53CP5jtDE1Wxe17TrV23yz4SCYoFnPFN38Azd-DH3-1ghBmawpZRkq9pAOPsZg22YIbpstNASaH9XNH9WZvz6MjqutNb_ovdvqG2bZeSk</recordid><startdate>19990101</startdate><enddate>19990101</enddate><creator>Dinkel, H</creator><creator>Moll, R</creator><creator>Fieger, M</creator><creator>Knüpffer, J</creator><creator>Schindler, G</creator><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QO</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>19990101</creationdate><title>Opacification of the urinary tract in portal venous spiral CT without delayed scans</title><author>Dinkel, H ; Moll, R ; Fieger, M ; Knüpffer, J ; Schindler, G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c316t-98f646a80189749d5cd872873c46dd5a8cd8bfec074a0edea2ffe5dbd67a56743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Contrast Media - administration & dosage</topic><topic>Humans</topic><topic>Iopamidol</topic><topic>Kidney - diagnostic imaging</topic><topic>Liver - diagnostic imaging</topic><topic>Lung cancer</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Portal Vein - diagnostic imaging</topic><topic>Prospective Studies</topic><topic>Time Factors</topic><topic>Tomography, X-Ray Computed - methods</topic><topic>Ureter - diagnostic imaging</topic><topic>Urogenital system</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dinkel, H</creatorcontrib><creatorcontrib>Moll, R</creatorcontrib><creatorcontrib>Fieger, M</creatorcontrib><creatorcontrib>Knüpffer, J</creatorcontrib><creatorcontrib>Schindler, G</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Biotechnology Research Abstracts</collection><collection>Proquest Nursing & Allied Health Source</collection><collection>ProQuest Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biological Science Database</collection><collection>Nursing & Allied Health Premium</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>European radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dinkel, H</au><au>Moll, R</au><au>Fieger, M</au><au>Knüpffer, J</au><au>Schindler, G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Opacification of the urinary tract in portal venous spiral CT without delayed scans</atitle><jtitle>European radiology</jtitle><addtitle>Eur Radiol</addtitle><date>1999-01-01</date><risdate>1999</risdate><volume>9</volume><issue>8</issue><spage>1579</spage><epage>1585</epage><pages>1579-1585</pages><issn>0938-7994</issn><eissn>1432-1084</eissn><abstract>In portal venous spiral CT there is no visible renal contrast excretion within the usual period of scanning. To opacify collecting systems additional delayed scanning is required. We administered an extra pre-dose of contrast medium before the main portal venous bolus in order to opacify the urinary tract and studied its effects on liver attenuation. In 32 patients examined first by non-contrast spiral CT 20 ml of a non-ionic IV CM were injected. Five minutes later, orientating cuts in the liver and along the urinary tract were obtained. Immediately thereafter, a 120-ml bolus was administered at 3 ml/s for portal venous phase helical CT (60-s delay craniocaudad). The quality of renal excretion was graded visually (excellent, fair, poor, none). Hepatic attenuation measurements were performed at comparable regions of interest. In all patients 20 ml CM opacified the renal pelvis after 5 min. Depiction of the ureters was excellent in 14, fair in 11 and poor or none in 7 cases. There was little effect on mean hepatic attenuation by the 20-ml pre-bolus after 5 min: mean enhancement 2.3 HU (range -0.6 to 7.8 HU). Mean hepatic enhancement after the 120-ml portal venous bolus ranged between 23.6 and 74.1 HU (mean 51.5 HU). When opacification of the urinary tract is necessary, pre-administration of a 20-ml bolus 5 min before portal venous scanning may save an extra delayed spiral. The effects on hepatic enhancement are negligible.</abstract><cop>Germany</cop><pub>Springer Nature B.V</pub><pmid>10525869</pmid><doi>10.1007/s003300050888</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0938-7994 |
ispartof | European radiology, 1999-01, Vol.9 (8), p.1579-1585 |
issn | 0938-7994 1432-1084 |
language | eng |
recordid | cdi_proquest_miscellaneous_70858403 |
source | Springer Link |
subjects | Contrast Media - administration & dosage Humans Iopamidol Kidney - diagnostic imaging Liver - diagnostic imaging Lung cancer Male Middle Aged Portal Vein - diagnostic imaging Prospective Studies Time Factors Tomography, X-Ray Computed - methods Ureter - diagnostic imaging Urogenital system |
title | Opacification of the urinary tract in portal venous spiral CT without delayed scans |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T19%3A38%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Opacification%20of%20the%20urinary%20tract%20in%20portal%20venous%20spiral%20CT%20without%20delayed%20scans&rft.jtitle=European%20radiology&rft.au=Dinkel,%20H&rft.date=1999-01-01&rft.volume=9&rft.issue=8&rft.spage=1579&rft.epage=1585&rft.pages=1579-1585&rft.issn=0938-7994&rft.eissn=1432-1084&rft_id=info:doi/10.1007/s003300050888&rft_dat=%3Cproquest_cross%3E2431580891%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c316t-98f646a80189749d5cd872873c46dd5a8cd8bfec074a0edea2ffe5dbd67a56743%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=884596445&rft_id=info:pmid/10525869&rfr_iscdi=true |