Loading…
Tools for flash-photolysis experiments on voltage-clamped muscle fibre segments
An experimental set-up is described that allows the combination of rapid transmembrane voltage changes and photometric calcium recording with the fast photochemical turnover of substances applied externally or intracellularly to cut skeletal muscle fibres. It consists of a double-vaseline-gap system...
Saved in:
Published in: | Pflügers Archiv 2000-01, Vol.439 (3), p.385-393 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c231t-375a0f405c590b8df290a5a122c24b0e17bba5f0a617fca5734891c24da072ca3 |
---|---|
cites | |
container_end_page | 393 |
container_issue | 3 |
container_start_page | 385 |
container_title | Pflügers Archiv |
container_volume | 439 |
creator | Schuhmeier, R P Tewes, S Szentesi, P Melzer, W |
description | An experimental set-up is described that allows the combination of rapid transmembrane voltage changes and photometric calcium recording with the fast photochemical turnover of substances applied externally or intracellularly to cut skeletal muscle fibres. It consists of a double-vaseline-gap system, designed for use with a xenon-flash-lamp device and a dual-wavelength microscope photometer. The pools of the vaseline gap chamber that contain the solutions surrounding the cut ends and the voltage-clamped segment of the muscle fibre are closed and have volumes of 20-50 microl. Thin tubes allow rapid solution change or continuous perfusion in the chamber compartments. Accessory tools were constructed to simplify focussing and measuring the flash-light intensity. A pilot light delivered from a red laser diode is used as a guide beam to target the ultraviolet (UV) flash to the preparation. The light distribution in the focal region and the relative changes in flash intensity with increasing numbers of flashes were quantified with an instrument that integrates the photo-current of a UV-sensitive silicon diode. The function of the set-up was demonstrated by measuring the efficiency of Ca2+ release from DM-nitrophen in quartz capillaries using the Ca(2+)-sensitive dye antipyrylazo III and by recording the flash-induced recovery of L-type calcium currents in muscle fibres blocked by the light-sensitive dihydropyridine drug nifedipine. |
doi_str_mv | 10.1007/s004249900102 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70884552</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2386657521</sourcerecordid><originalsourceid>FETCH-LOGICAL-c231t-375a0f405c590b8df290a5a122c24b0e17bba5f0a617fca5734891c24da072ca3</originalsourceid><addsrcrecordid>eNpdkDtPwzAUhS0EoqUwsiKLgS1w_YqdESFeUqUuZY4cx25TOXWwE0T_PYF2AKY7nE9H534IXRK4JQDyLgFwyosCgAA9QlPCGc0oEHaMpgCMZLnM1QSdpbQBAMoVPUUTArmAoqBTtFiG4BN2IWLndVpn3Tr0we9Sk7D97GxsWrvtEw5b_BF8r1c2M163na1xOyTjLXZNFS1OdvUDnqMTp32yF4c7Q29Pj8uHl2y-eH59uJ9nhjLSZ0wKDY6DMKKAStWOFqCFJpQayiuwRFaVFg50TqQzWkjGVUHGrNYgqdFshm72vV0M74NNfdk2yVjv9daGIZUSlOJC0BG8_gduwhC347ZSSQ6UqdHYDGV7yMSQUrSu7MbHddyVBMpvzeUfzSN_dSgdqtbWv-i9V_YFPSR3Tw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>874023814</pqid></control><display><type>article</type><title>Tools for flash-photolysis experiments on voltage-clamped muscle fibre segments</title><source>Springer Link</source><creator>Schuhmeier, R P ; Tewes, S ; Szentesi, P ; Melzer, W</creator><creatorcontrib>Schuhmeier, R P ; Tewes, S ; Szentesi, P ; Melzer, W</creatorcontrib><description>An experimental set-up is described that allows the combination of rapid transmembrane voltage changes and photometric calcium recording with the fast photochemical turnover of substances applied externally or intracellularly to cut skeletal muscle fibres. It consists of a double-vaseline-gap system, designed for use with a xenon-flash-lamp device and a dual-wavelength microscope photometer. The pools of the vaseline gap chamber that contain the solutions surrounding the cut ends and the voltage-clamped segment of the muscle fibre are closed and have volumes of 20-50 microl. Thin tubes allow rapid solution change or continuous perfusion in the chamber compartments. Accessory tools were constructed to simplify focussing and measuring the flash-light intensity. A pilot light delivered from a red laser diode is used as a guide beam to target the ultraviolet (UV) flash to the preparation. The light distribution in the focal region and the relative changes in flash intensity with increasing numbers of flashes were quantified with an instrument that integrates the photo-current of a UV-sensitive silicon diode. The function of the set-up was demonstrated by measuring the efficiency of Ca2+ release from DM-nitrophen in quartz capillaries using the Ca(2+)-sensitive dye antipyrylazo III and by recording the flash-induced recovery of L-type calcium currents in muscle fibres blocked by the light-sensitive dihydropyridine drug nifedipine.</description><identifier>ISSN: 0031-6768</identifier><identifier>EISSN: 1432-2013</identifier><identifier>DOI: 10.1007/s004249900102</identifier><identifier>PMID: 10650992</identifier><language>eng</language><publisher>Germany: Springer Nature B.V</publisher><subject>Acetates - pharmacology ; Algorithms ; Animals ; Calcium Channel Blockers - pharmacology ; Calcium Channels, L-Type - drug effects ; Calcium Channels, L-Type - metabolism ; Calcium Signaling - drug effects ; Chelating Agents - pharmacology ; Ethylenediamines - pharmacology ; In Vitro Techniques ; Membrane Potentials - physiology ; Muscle Fibers, Skeletal - metabolism ; Muscle Fibers, Skeletal - physiology ; Nifedipine - pharmacology ; Patch-Clamp Techniques ; Photolysis ; Photometry ; Rana pipiens ; Studies ; Ultraviolet Rays</subject><ispartof>Pflügers Archiv, 2000-01, Vol.439 (3), p.385-393</ispartof><rights>Springer-Verlag 0000</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c231t-375a0f405c590b8df290a5a122c24b0e17bba5f0a617fca5734891c24da072ca3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10650992$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Schuhmeier, R P</creatorcontrib><creatorcontrib>Tewes, S</creatorcontrib><creatorcontrib>Szentesi, P</creatorcontrib><creatorcontrib>Melzer, W</creatorcontrib><title>Tools for flash-photolysis experiments on voltage-clamped muscle fibre segments</title><title>Pflügers Archiv</title><addtitle>Pflugers Arch</addtitle><description>An experimental set-up is described that allows the combination of rapid transmembrane voltage changes and photometric calcium recording with the fast photochemical turnover of substances applied externally or intracellularly to cut skeletal muscle fibres. It consists of a double-vaseline-gap system, designed for use with a xenon-flash-lamp device and a dual-wavelength microscope photometer. The pools of the vaseline gap chamber that contain the solutions surrounding the cut ends and the voltage-clamped segment of the muscle fibre are closed and have volumes of 20-50 microl. Thin tubes allow rapid solution change or continuous perfusion in the chamber compartments. Accessory tools were constructed to simplify focussing and measuring the flash-light intensity. A pilot light delivered from a red laser diode is used as a guide beam to target the ultraviolet (UV) flash to the preparation. The light distribution in the focal region and the relative changes in flash intensity with increasing numbers of flashes were quantified with an instrument that integrates the photo-current of a UV-sensitive silicon diode. The function of the set-up was demonstrated by measuring the efficiency of Ca2+ release from DM-nitrophen in quartz capillaries using the Ca(2+)-sensitive dye antipyrylazo III and by recording the flash-induced recovery of L-type calcium currents in muscle fibres blocked by the light-sensitive dihydropyridine drug nifedipine.</description><subject>Acetates - pharmacology</subject><subject>Algorithms</subject><subject>Animals</subject><subject>Calcium Channel Blockers - pharmacology</subject><subject>Calcium Channels, L-Type - drug effects</subject><subject>Calcium Channels, L-Type - metabolism</subject><subject>Calcium Signaling - drug effects</subject><subject>Chelating Agents - pharmacology</subject><subject>Ethylenediamines - pharmacology</subject><subject>In Vitro Techniques</subject><subject>Membrane Potentials - physiology</subject><subject>Muscle Fibers, Skeletal - metabolism</subject><subject>Muscle Fibers, Skeletal - physiology</subject><subject>Nifedipine - pharmacology</subject><subject>Patch-Clamp Techniques</subject><subject>Photolysis</subject><subject>Photometry</subject><subject>Rana pipiens</subject><subject>Studies</subject><subject>Ultraviolet Rays</subject><issn>0031-6768</issn><issn>1432-2013</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNpdkDtPwzAUhS0EoqUwsiKLgS1w_YqdESFeUqUuZY4cx25TOXWwE0T_PYF2AKY7nE9H534IXRK4JQDyLgFwyosCgAA9QlPCGc0oEHaMpgCMZLnM1QSdpbQBAMoVPUUTArmAoqBTtFiG4BN2IWLndVpn3Tr0we9Sk7D97GxsWrvtEw5b_BF8r1c2M163na1xOyTjLXZNFS1OdvUDnqMTp32yF4c7Q29Pj8uHl2y-eH59uJ9nhjLSZ0wKDY6DMKKAStWOFqCFJpQayiuwRFaVFg50TqQzWkjGVUHGrNYgqdFshm72vV0M74NNfdk2yVjv9daGIZUSlOJC0BG8_gduwhC347ZSSQ6UqdHYDGV7yMSQUrSu7MbHddyVBMpvzeUfzSN_dSgdqtbWv-i9V_YFPSR3Tw</recordid><startdate>200001</startdate><enddate>200001</enddate><creator>Schuhmeier, R P</creator><creator>Tewes, S</creator><creator>Szentesi, P</creator><creator>Melzer, W</creator><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QP</scope><scope>7TK</scope><scope>7TS</scope><scope>7X7</scope><scope>7XB</scope><scope>88A</scope><scope>88E</scope><scope>8AO</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>7X8</scope></search><sort><creationdate>200001</creationdate><title>Tools for flash-photolysis experiments on voltage-clamped muscle fibre segments</title><author>Schuhmeier, R P ; Tewes, S ; Szentesi, P ; Melzer, W</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c231t-375a0f405c590b8df290a5a122c24b0e17bba5f0a617fca5734891c24da072ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Acetates - pharmacology</topic><topic>Algorithms</topic><topic>Animals</topic><topic>Calcium Channel Blockers - pharmacology</topic><topic>Calcium Channels, L-Type - drug effects</topic><topic>Calcium Channels, L-Type - metabolism</topic><topic>Calcium Signaling - drug effects</topic><topic>Chelating Agents - pharmacology</topic><topic>Ethylenediamines - pharmacology</topic><topic>In Vitro Techniques</topic><topic>Membrane Potentials - physiology</topic><topic>Muscle Fibers, Skeletal - metabolism</topic><topic>Muscle Fibers, Skeletal - physiology</topic><topic>Nifedipine - pharmacology</topic><topic>Patch-Clamp Techniques</topic><topic>Photolysis</topic><topic>Photometry</topic><topic>Rana pipiens</topic><topic>Studies</topic><topic>Ultraviolet Rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schuhmeier, R P</creatorcontrib><creatorcontrib>Tewes, S</creatorcontrib><creatorcontrib>Szentesi, P</creatorcontrib><creatorcontrib>Melzer, W</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>Physical Education Index</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Biology Database (Alumni Edition)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>PML(ProQuest Medical Library)</collection><collection>Biological Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>MEDLINE - Academic</collection><jtitle>Pflügers Archiv</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schuhmeier, R P</au><au>Tewes, S</au><au>Szentesi, P</au><au>Melzer, W</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Tools for flash-photolysis experiments on voltage-clamped muscle fibre segments</atitle><jtitle>Pflügers Archiv</jtitle><addtitle>Pflugers Arch</addtitle><date>2000-01</date><risdate>2000</risdate><volume>439</volume><issue>3</issue><spage>385</spage><epage>393</epage><pages>385-393</pages><issn>0031-6768</issn><eissn>1432-2013</eissn><abstract>An experimental set-up is described that allows the combination of rapid transmembrane voltage changes and photometric calcium recording with the fast photochemical turnover of substances applied externally or intracellularly to cut skeletal muscle fibres. It consists of a double-vaseline-gap system, designed for use with a xenon-flash-lamp device and a dual-wavelength microscope photometer. The pools of the vaseline gap chamber that contain the solutions surrounding the cut ends and the voltage-clamped segment of the muscle fibre are closed and have volumes of 20-50 microl. Thin tubes allow rapid solution change or continuous perfusion in the chamber compartments. Accessory tools were constructed to simplify focussing and measuring the flash-light intensity. A pilot light delivered from a red laser diode is used as a guide beam to target the ultraviolet (UV) flash to the preparation. The light distribution in the focal region and the relative changes in flash intensity with increasing numbers of flashes were quantified with an instrument that integrates the photo-current of a UV-sensitive silicon diode. The function of the set-up was demonstrated by measuring the efficiency of Ca2+ release from DM-nitrophen in quartz capillaries using the Ca(2+)-sensitive dye antipyrylazo III and by recording the flash-induced recovery of L-type calcium currents in muscle fibres blocked by the light-sensitive dihydropyridine drug nifedipine.</abstract><cop>Germany</cop><pub>Springer Nature B.V</pub><pmid>10650992</pmid><doi>10.1007/s004249900102</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0031-6768 |
ispartof | Pflügers Archiv, 2000-01, Vol.439 (3), p.385-393 |
issn | 0031-6768 1432-2013 |
language | eng |
recordid | cdi_proquest_miscellaneous_70884552 |
source | Springer Link |
subjects | Acetates - pharmacology Algorithms Animals Calcium Channel Blockers - pharmacology Calcium Channels, L-Type - drug effects Calcium Channels, L-Type - metabolism Calcium Signaling - drug effects Chelating Agents - pharmacology Ethylenediamines - pharmacology In Vitro Techniques Membrane Potentials - physiology Muscle Fibers, Skeletal - metabolism Muscle Fibers, Skeletal - physiology Nifedipine - pharmacology Patch-Clamp Techniques Photolysis Photometry Rana pipiens Studies Ultraviolet Rays |
title | Tools for flash-photolysis experiments on voltage-clamped muscle fibre segments |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T18%3A04%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Tools%20for%20flash-photolysis%20experiments%20on%20voltage-clamped%20muscle%20fibre%20segments&rft.jtitle=Pfl%C3%BCgers%20Archiv&rft.au=Schuhmeier,%20R%20P&rft.date=2000-01&rft.volume=439&rft.issue=3&rft.spage=385&rft.epage=393&rft.pages=385-393&rft.issn=0031-6768&rft.eissn=1432-2013&rft_id=info:doi/10.1007/s004249900102&rft_dat=%3Cproquest_cross%3E2386657521%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c231t-375a0f405c590b8df290a5a122c24b0e17bba5f0a617fca5734891c24da072ca3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=874023814&rft_id=info:pmid/10650992&rfr_iscdi=true |