Loading…

First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation

A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. Two male patie...

Full description

Saved in:
Bibliographic Details
Published in:Circulation (New York, N.Y.) N.Y.), 2000-02, Vol.101 (4), p.356-359
Main Authors: WIESELTHALER, G. M, SCHIMA, H, HIESMAYR, M, PACHER, R, LAUFER, G, NOON, G. P, DEBAKEY, M, WOLNER, E
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c434t-addb87985d2a9276d047524300ebce4e95708b8ebe0d7ccd193a0df4f0824bee3
cites cdi_FETCH-LOGICAL-c434t-addb87985d2a9276d047524300ebce4e95708b8ebe0d7ccd193a0df4f0824bee3
container_end_page 359
container_issue 4
container_start_page 356
container_title Circulation (New York, N.Y.)
container_volume 101
creator WIESELTHALER, G. M
SCHIMA, H
HIESMAYR, M
PACHER, R
LAUFER, G
NOON, G. P
DEBAKEY, M
WOLNER, E
description A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump flow was 3.9+/-0.5 L/min, which equals a mean cardiac index (CI) of 2.3+/-0.2 L. min(-1). m(-2). In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5+/-0.6 L/min, causing an increase of mean CI up to 2.7+/-0.2 L. min(-1). m(-2). Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly from 2. 1+/-0.8 mg/dL before surgery to 3.3+/-1.8 mg/dL 6 weeks after implantation. The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.
doi_str_mv 10.1161/01.CIR.101.4.356
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70887887</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77151498</sourcerecordid><originalsourceid>FETCH-LOGICAL-c434t-addb87985d2a9276d047524300ebce4e95708b8ebe0d7ccd193a0df4f0824bee3</originalsourceid><addsrcrecordid>eNpdkc1r3DAQxUVoaDZp7zkVUUpu3urLln1MNk0bCBRK26uQpXGixGs5kkyS_75TdqElIBgGfm_05g0hp5ytOW_4Z8bXm-sfa45VrWXdHJAVr4WqVC27N2TFGOsqLYU4Isc532PbSF2_JUecNbVshVqR26uQcqFuDFNwdqTwPEMKMDmgT6Hc0XIH9BIu7AO80N_nl9TFqYRpiUuu7HOwYzWM8YnOy3amQ0y0T8HfAi2RlmSnPI92KraEOL0jh4MdM7zf1xPy6-rLz8236ub71-vN-U3llFSlst73re7a2gvbCd14pjQuJBmD3oGCrtas7VvogXntnOedtMwPamC4TQ8gT8jZbu6c4uMCuZhtyA5GNAJo2qC81fgQ_PgKvI9LmtCbERx_brtOIsR2kEsx5wSDmVPY2vRiODN_L2AYN3gBbLlRBi-Akg_7uUu_Bf-fYBc5Ap_2gM2Y-IA5uZD_caLWQnP5B-2yjsU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>212768993</pqid></control><display><type>article</type><title>First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>WIESELTHALER, G. M ; SCHIMA, H ; HIESMAYR, M ; PACHER, R ; LAUFER, G ; NOON, G. P ; DEBAKEY, M ; WOLNER, E</creator><creatorcontrib>WIESELTHALER, G. M ; SCHIMA, H ; HIESMAYR, M ; PACHER, R ; LAUFER, G ; NOON, G. P ; DEBAKEY, M ; WOLNER, E</creatorcontrib><description>A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump flow was 3.9+/-0.5 L/min, which equals a mean cardiac index (CI) of 2.3+/-0.2 L. min(-1). m(-2). In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5+/-0.6 L/min, causing an increase of mean CI up to 2.7+/-0.2 L. min(-1). m(-2). Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly from 2. 1+/-0.8 mg/dL before surgery to 3.3+/-1.8 mg/dL 6 weeks after implantation. The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.</description><identifier>ISSN: 0009-7322</identifier><identifier>EISSN: 1524-4539</identifier><identifier>DOI: 10.1161/01.CIR.101.4.356</identifier><identifier>PMID: 10653824</identifier><identifier>CODEN: CIRCAZ</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott Williams &amp; Wilkins</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Cardiology. Vascular system ; Cardiomyopathy, Dilated - complications ; Cardiomyopathy, Dilated - therapy ; Equipment Design ; Heart ; Heart Failure - therapy ; Heart failure, cardiogenic pulmonary edema, cardiac enlargement ; Heart Transplantation ; Heart-Assist Devices - adverse effects ; Hemolysis ; Humans ; Male ; Medical sciences ; Myocardial Ischemia - complications ; Myocardial Ischemia - therapy ; Tissue Donors - supply &amp; distribution</subject><ispartof>Circulation (New York, N.Y.), 2000-02, Vol.101 (4), p.356-359</ispartof><rights>2000 INIST-CNRS</rights><rights>Copyright American Heart Association, Inc. Feb 1, 2000</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c434t-addb87985d2a9276d047524300ebce4e95708b8ebe0d7ccd193a0df4f0824bee3</citedby><cites>FETCH-LOGICAL-c434t-addb87985d2a9276d047524300ebce4e95708b8ebe0d7ccd193a0df4f0824bee3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1257271$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10653824$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>WIESELTHALER, G. M</creatorcontrib><creatorcontrib>SCHIMA, H</creatorcontrib><creatorcontrib>HIESMAYR, M</creatorcontrib><creatorcontrib>PACHER, R</creatorcontrib><creatorcontrib>LAUFER, G</creatorcontrib><creatorcontrib>NOON, G. P</creatorcontrib><creatorcontrib>DEBAKEY, M</creatorcontrib><creatorcontrib>WOLNER, E</creatorcontrib><title>First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation</title><title>Circulation (New York, N.Y.)</title><addtitle>Circulation</addtitle><description>A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump flow was 3.9+/-0.5 L/min, which equals a mean cardiac index (CI) of 2.3+/-0.2 L. min(-1). m(-2). In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5+/-0.6 L/min, causing an increase of mean CI up to 2.7+/-0.2 L. min(-1). m(-2). Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly from 2. 1+/-0.8 mg/dL before surgery to 3.3+/-1.8 mg/dL 6 weeks after implantation. The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Cardiology. Vascular system</subject><subject>Cardiomyopathy, Dilated - complications</subject><subject>Cardiomyopathy, Dilated - therapy</subject><subject>Equipment Design</subject><subject>Heart</subject><subject>Heart Failure - therapy</subject><subject>Heart failure, cardiogenic pulmonary edema, cardiac enlargement</subject><subject>Heart Transplantation</subject><subject>Heart-Assist Devices - adverse effects</subject><subject>Hemolysis</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Myocardial Ischemia - complications</subject><subject>Myocardial Ischemia - therapy</subject><subject>Tissue Donors - supply &amp; distribution</subject><issn>0009-7322</issn><issn>1524-4539</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNpdkc1r3DAQxUVoaDZp7zkVUUpu3urLln1MNk0bCBRK26uQpXGixGs5kkyS_75TdqElIBgGfm_05g0hp5ytOW_4Z8bXm-sfa45VrWXdHJAVr4WqVC27N2TFGOsqLYU4Isc532PbSF2_JUecNbVshVqR26uQcqFuDFNwdqTwPEMKMDmgT6Hc0XIH9BIu7AO80N_nl9TFqYRpiUuu7HOwYzWM8YnOy3amQ0y0T8HfAi2RlmSnPI92KraEOL0jh4MdM7zf1xPy6-rLz8236ub71-vN-U3llFSlst73re7a2gvbCd14pjQuJBmD3oGCrtas7VvogXntnOedtMwPamC4TQ8gT8jZbu6c4uMCuZhtyA5GNAJo2qC81fgQ_PgKvI9LmtCbERx_brtOIsR2kEsx5wSDmVPY2vRiODN_L2AYN3gBbLlRBi-Akg_7uUu_Bf-fYBc5Ap_2gM2Y-IA5uZD_caLWQnP5B-2yjsU</recordid><startdate>20000201</startdate><enddate>20000201</enddate><creator>WIESELTHALER, G. M</creator><creator>SCHIMA, H</creator><creator>HIESMAYR, M</creator><creator>PACHER, R</creator><creator>LAUFER, G</creator><creator>NOON, G. P</creator><creator>DEBAKEY, M</creator><creator>WOLNER, E</creator><general>Lippincott Williams &amp; Wilkins</general><general>American Heart Association, Inc</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>U9A</scope><scope>7X8</scope></search><sort><creationdate>20000201</creationdate><title>First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation</title><author>WIESELTHALER, G. M ; SCHIMA, H ; HIESMAYR, M ; PACHER, R ; LAUFER, G ; NOON, G. P ; DEBAKEY, M ; WOLNER, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c434t-addb87985d2a9276d047524300ebce4e95708b8ebe0d7ccd193a0df4f0824bee3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Cardiology. Vascular system</topic><topic>Cardiomyopathy, Dilated - complications</topic><topic>Cardiomyopathy, Dilated - therapy</topic><topic>Equipment Design</topic><topic>Heart</topic><topic>Heart Failure - therapy</topic><topic>Heart failure, cardiogenic pulmonary edema, cardiac enlargement</topic><topic>Heart Transplantation</topic><topic>Heart-Assist Devices - adverse effects</topic><topic>Hemolysis</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Myocardial Ischemia - complications</topic><topic>Myocardial Ischemia - therapy</topic><topic>Tissue Donors - supply &amp; distribution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>WIESELTHALER, G. M</creatorcontrib><creatorcontrib>SCHIMA, H</creatorcontrib><creatorcontrib>HIESMAYR, M</creatorcontrib><creatorcontrib>PACHER, R</creatorcontrib><creatorcontrib>LAUFER, G</creatorcontrib><creatorcontrib>NOON, G. P</creatorcontrib><creatorcontrib>DEBAKEY, M</creatorcontrib><creatorcontrib>WOLNER, E</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>MEDLINE - Academic</collection><jtitle>Circulation (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>WIESELTHALER, G. M</au><au>SCHIMA, H</au><au>HIESMAYR, M</au><au>PACHER, R</au><au>LAUFER, G</au><au>NOON, G. P</au><au>DEBAKEY, M</au><au>WOLNER, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation</atitle><jtitle>Circulation (New York, N.Y.)</jtitle><addtitle>Circulation</addtitle><date>2000-02-01</date><risdate>2000</risdate><volume>101</volume><issue>4</issue><spage>356</spage><epage>359</epage><pages>356-359</pages><issn>0009-7322</issn><eissn>1524-4539</eissn><coden>CIRCAZ</coden><abstract>A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump flow was 3.9+/-0.5 L/min, which equals a mean cardiac index (CI) of 2.3+/-0.2 L. min(-1). m(-2). In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5+/-0.6 L/min, causing an increase of mean CI up to 2.7+/-0.2 L. min(-1). m(-2). Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly from 2. 1+/-0.8 mg/dL before surgery to 3.3+/-1.8 mg/dL 6 weeks after implantation. The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott Williams &amp; Wilkins</pub><pmid>10653824</pmid><doi>10.1161/01.CIR.101.4.356</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0009-7322
ispartof Circulation (New York, N.Y.), 2000-02, Vol.101 (4), p.356-359
issn 0009-7322
1524-4539
language eng
recordid cdi_proquest_miscellaneous_70887887
source EZB-FREE-00999 freely available EZB journals
subjects Adult
Aged
Biological and medical sciences
Cardiology. Vascular system
Cardiomyopathy, Dilated - complications
Cardiomyopathy, Dilated - therapy
Equipment Design
Heart
Heart Failure - therapy
Heart failure, cardiogenic pulmonary edema, cardiac enlargement
Heart Transplantation
Heart-Assist Devices - adverse effects
Hemolysis
Humans
Male
Medical sciences
Myocardial Ischemia - complications
Myocardial Ischemia - therapy
Tissue Donors - supply & distribution
title First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T03%3A38%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=First%20clinical%20experience%20with%20the%20DeBakey%20VAD%20continuous-axial-flow%20pump%20for%20bridge%20to%20transplantation&rft.jtitle=Circulation%20(New%20York,%20N.Y.)&rft.au=WIESELTHALER,%20G.%20M&rft.date=2000-02-01&rft.volume=101&rft.issue=4&rft.spage=356&rft.epage=359&rft.pages=356-359&rft.issn=0009-7322&rft.eissn=1524-4539&rft.coden=CIRCAZ&rft_id=info:doi/10.1161/01.CIR.101.4.356&rft_dat=%3Cproquest_cross%3E77151498%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c434t-addb87985d2a9276d047524300ebce4e95708b8ebe0d7ccd193a0df4f0824bee3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=212768993&rft_id=info:pmid/10653824&rfr_iscdi=true