Accuracy of Intravascular Ultrasound for Diameter Measurement of Phantom Arteries

Background. Uniplanar quantitative angiography (QA) is the standard method for measuring vessel diameter during surgical and endovascular procedures. Intravascular ultrasound (IVUS), a relatively new technology, is another means of obtaining this measurement. This study was designed to validate the...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of surgical research 2001-09, Vol.100 (1), p.99-105
Main Authors: Cooper, Benjamin Z., Kirwin, Jon D., Panetta, Thomas F., Weinreb, F.Michele, Ramirez, Jose A., Najjar, John G., Blattman, Seth B., Rodino, William, Song, Mark
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background. Uniplanar quantitative angiography (QA) is the standard method for measuring vessel diameter during surgical and endovascular procedures. Intravascular ultrasound (IVUS), a relatively new technology, is another means of obtaining this measurement. This study was designed to validate the accuracy of these two modalities by comparing each to direct caliper measurement, the gold standard, using phantom femoral artery segments (PAS). Materials and methods. PAS diameter was measured with a 12.5-MHz mechanically rotating IVUS catheter (Boston Scientific Corp.) and QA (OEC Corp.) was compared to the direct caliper measurement (Mitutoyo Corp.) at 60 different locations within PAS. At each location minimal lumen diameter and perpendicular lumen diameter were measured and their mean was calculated. The intraclass correlation coefficients (ICCC) between direct caliper measurement and IVUS and uniplanar and biplanar angiography were calculated. Fisher's Z transformation was used to compare the correlation coefficients. Results. The ICCC for IVUS was 0.89. The ICCCs for uniplanar and biplanar angiography were 0.73 and 0.82, respectively. IVUS correlated more closely with direct caliper measurement than uniplanar and biplanar angiography (P = 0.00008, 0.02) Biplanar angiography correlated more closely with direct caliper measurement than uniplanar angiography (P = 0.04). Conclusions. IVUS more accurately measures lumen diameter than uniplanar or biplanar angiography. Diameter measurement with biplanar angiography is more accurate than uniplanar angiography.
ISSN:0022-4804
1095-8673