Loading…

The reliability of vital sign measurements

Study objective: Vital sign measurements, specifically heart rate, respiratory rate, and blood pressure, play a fundamental role in many medical evaluations, yet little is known about the reliability of noninvasive vital sign measurements. We sought to determine whether trained observers can reprodu...

Full description

Saved in:
Bibliographic Details
Published in:Annals of emergency medicine 2002-03, Vol.39 (3), p.233-237
Main Authors: Edmonds, Zachary V., Mower, William R., Lovato, Luis M., Lomeli, Rosaelva
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Study objective: Vital sign measurements, specifically heart rate, respiratory rate, and blood pressure, play a fundamental role in many medical evaluations, yet little is known about the reliability of noninvasive vital sign measurements. We sought to determine whether trained observers can reproducibly assess vital signs in the clinical setting. Methods: Two trained observers independently measured vital signs on 140 patients presenting to an urban emergency department with acute medical complaints. Heart rate and respiratory rate were each measured by auscultation of heart and breath sounds for 1 minute. Systolic and diastolic blood pressures were determined by auscultating Korotkoff sounds while viewing pressure measurements from a standard cuff and mercury manometer. The mean value of each vital sign and Bland-Altman statistics (mean difference between observers [MDO], expected range of agreement [ERA]) were used to provide absolute and relative indices of reliability. Results: The observers found a mean heart rate of 78.5 beats/min, with an MDO of 0.02 beats/min (0.03%), and an ERA of ±10.6 beats/min (±13.5%). Respiratory rate exhibited a mean of 17.5 breaths/min, an MDO of 0.04 breaths/min (0.2%), and an ERA of ±6.2 breaths/min (±35.5%). The mean systolic blood pressure of 127.1 mm Hg was associated with an MDO of 1.3 mm Hg (1.0%), and an ERA of ±24.2 mm Hg (±19.0%). Diastolic blood pressure exhibited a mean of 77.4 mm Hg, an MDO of 0.3 mm Hg (0.4%) with an ERA of ±19.9 mm Hg (±25.7%). Conclusion: The reproducibility of vital sign measurements may be limited by significant interobserver variability. Clinicians should recognize this inherent variability and interpret vital signs with caution. [Edmonds ZV, Mower WR, Lovato LM, Lomeli R. The reliability of vital sign measurements. Ann Emerg Med. March 2002;39:233-237.]
ISSN:0196-0644
1097-6760
DOI:10.1067/mem.2002.122017