A UK Multi-centre Experience with a Second-generation Endovascular Stent-graft: Results from the Zenith Users Group
Background. Endovascular aneurysm repair has been criticised for high rates of technical failure and secondary intervention. Second generation stent-grafts have been developed in an attempt to reduce these problems. The results of a UK multi-centre experience with a second generation device (Zenith)...
Saved in:
Published in: | European journal of vascular and endovascular surgery 2004, Vol.27 (1), p.51-55 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c398t-6584d63abb8275c873c0da1168786893e4a42772ea02bf83954d7f7f7e6de34e3 |
---|---|
cites | cdi_FETCH-LOGICAL-c398t-6584d63abb8275c873c0da1168786893e4a42772ea02bf83954d7f7f7e6de34e3 |
container_end_page | 55 |
container_issue | 1 |
container_start_page | 51 |
container_title | European journal of vascular and endovascular surgery |
container_volume | 27 |
creator | Hinchliffe, R.J Goldberg, J MacSweeney, S.T.R On behalf of the Zenith Users Group |
description | Background. Endovascular aneurysm repair has been criticised for high rates of technical failure and secondary intervention. Second generation stent-grafts have been developed in an attempt to reduce these problems. The results of a UK multi-centre experience with a second generation device (Zenith) are presented.
Methods. Data were collected retrospectively from five experienced UK vascular centres in patients undergoing endovascular aneurysm repair with the Zenith stent-graft.
Results. A total of 269 patients underwent attempted aneurysm repair with the Zenith device. Median aneurysm diameter was 65 (interquartile range 52–78)
mm. There were no conversions to open repair. Peri-operative mortality was 4.1% (11/269). On the initial post-operative scan, 94.1% of aneurysms were successfully excluded. During a median follow-up of 363 (interquartile range 154–720) days there were 19 secondary interventions and two aneurysm ruptures.
Conclusions. Second generation endovascular stent-graft designs such as the Zenith are associated with low rates of intra-operative technical complications. Few secondary interventions have been necessary during follow-up; however, surveillance is essential to ensure they continue to perform. |
doi_str_mv | 10.1016/j.ejvs.2003.10.004 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71547761</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1078588403004854</els_id><sourcerecordid>71547761</sourcerecordid><originalsourceid>FETCH-LOGICAL-c398t-6584d63abb8275c873c0da1168786893e4a42772ea02bf83954d7f7f7e6de34e3</originalsourceid><addsrcrecordid>eNp9kM1uEzEURi0EoqXwAiyQV-wm9b8dxKaqQkEtQqJkw8Zy7Duto8k42J4Ab4-HRGKH7sJXV993JB-EXlOyoISqy-0CtoeyYITwdlgQIp6gcyo56xhV8mnbiTadNEacoRelbAkhknL5HJ1RoSQzXJ-jcoXXt_jzNNTYeRhrBrz6tYccYfSAf8b6iB2-B5_G0D3ACNnVmEa8GkM6uOKnwWV8X1uxe8iur-_wVygNVnCf0w7XR8DfYZwp6wK54Jucpv1L9Kx3Q4FXp_cCrT-svl1_7O6-3Hy6vrrrPF-a2ilpRFDcbTaGaemN5p4ER6ky2iiz5CCcYFozcIRtesOXUgTdtwEVgAvgF-jtkbvP6ccEpdpdLB6GwY2QpmI1lUJrRVuQHYM-p1Iy9Haf487l35YSO6u2WzurtrPq-dZUt9KbE33a7CD8q5zctsD7YwDaHw8Rsi3-r9YQM_hqQ4r_4_8BGZ2QNg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71547761</pqid></control><display><type>article</type><title>A UK Multi-centre Experience with a Second-generation Endovascular Stent-graft: Results from the Zenith Users Group</title><source>Elsevier</source><creator>Hinchliffe, R.J ; Goldberg, J ; MacSweeney, S.T.R ; On behalf of the Zenith Users Group</creator><creatorcontrib>Hinchliffe, R.J ; Goldberg, J ; MacSweeney, S.T.R ; On behalf of the Zenith Users Group ; Zenith Users Group</creatorcontrib><description>Background. Endovascular aneurysm repair has been criticised for high rates of technical failure and secondary intervention. Second generation stent-grafts have been developed in an attempt to reduce these problems. The results of a UK multi-centre experience with a second generation device (Zenith) are presented.
Methods. Data were collected retrospectively from five experienced UK vascular centres in patients undergoing endovascular aneurysm repair with the Zenith stent-graft.
Results. A total of 269 patients underwent attempted aneurysm repair with the Zenith device. Median aneurysm diameter was 65 (interquartile range 52–78)
mm. There were no conversions to open repair. Peri-operative mortality was 4.1% (11/269). On the initial post-operative scan, 94.1% of aneurysms were successfully excluded. During a median follow-up of 363 (interquartile range 154–720) days there were 19 secondary interventions and two aneurysm ruptures.
Conclusions. Second generation endovascular stent-graft designs such as the Zenith are associated with low rates of intra-operative technical complications. Few secondary interventions have been necessary during follow-up; however, surveillance is essential to ensure they continue to perform.</description><identifier>ISSN: 1078-5884</identifier><identifier>EISSN: 1532-2165</identifier><identifier>DOI: 10.1016/j.ejvs.2003.10.004</identifier><identifier>PMID: 14652837</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Abdominal aortic aneurysm ; Aged ; Aortic Aneurysm, Abdominal - surgery ; Blood Vessel Prosthesis ; Endovascular aneurysm repair ; Female ; Humans ; Male ; Prosthesis Design ; Stents ; Treatment Outcome ; Zenith stent-graft</subject><ispartof>European journal of vascular and endovascular surgery, 2004, Vol.27 (1), p.51-55</ispartof><rights>2003 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c398t-6584d63abb8275c873c0da1168786893e4a42772ea02bf83954d7f7f7e6de34e3</citedby><cites>FETCH-LOGICAL-c398t-6584d63abb8275c873c0da1168786893e4a42772ea02bf83954d7f7f7e6de34e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4022,27922,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/14652837$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hinchliffe, R.J</creatorcontrib><creatorcontrib>Goldberg, J</creatorcontrib><creatorcontrib>MacSweeney, S.T.R</creatorcontrib><creatorcontrib>On behalf of the Zenith Users Group</creatorcontrib><creatorcontrib>Zenith Users Group</creatorcontrib><title>A UK Multi-centre Experience with a Second-generation Endovascular Stent-graft: Results from the Zenith Users Group</title><title>European journal of vascular and endovascular surgery</title><addtitle>Eur J Vasc Endovasc Surg</addtitle><description>Background. Endovascular aneurysm repair has been criticised for high rates of technical failure and secondary intervention. Second generation stent-grafts have been developed in an attempt to reduce these problems. The results of a UK multi-centre experience with a second generation device (Zenith) are presented.
Methods. Data were collected retrospectively from five experienced UK vascular centres in patients undergoing endovascular aneurysm repair with the Zenith stent-graft.
Results. A total of 269 patients underwent attempted aneurysm repair with the Zenith device. Median aneurysm diameter was 65 (interquartile range 52–78)
mm. There were no conversions to open repair. Peri-operative mortality was 4.1% (11/269). On the initial post-operative scan, 94.1% of aneurysms were successfully excluded. During a median follow-up of 363 (interquartile range 154–720) days there were 19 secondary interventions and two aneurysm ruptures.
Conclusions. Second generation endovascular stent-graft designs such as the Zenith are associated with low rates of intra-operative technical complications. Few secondary interventions have been necessary during follow-up; however, surveillance is essential to ensure they continue to perform.</description><subject>Abdominal aortic aneurysm</subject><subject>Aged</subject><subject>Aortic Aneurysm, Abdominal - surgery</subject><subject>Blood Vessel Prosthesis</subject><subject>Endovascular aneurysm repair</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Prosthesis Design</subject><subject>Stents</subject><subject>Treatment Outcome</subject><subject>Zenith stent-graft</subject><issn>1078-5884</issn><issn>1532-2165</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNp9kM1uEzEURi0EoqXwAiyQV-wm9b8dxKaqQkEtQqJkw8Zy7Duto8k42J4Ab4-HRGKH7sJXV993JB-EXlOyoISqy-0CtoeyYITwdlgQIp6gcyo56xhV8mnbiTadNEacoRelbAkhknL5HJ1RoSQzXJ-jcoXXt_jzNNTYeRhrBrz6tYccYfSAf8b6iB2-B5_G0D3ACNnVmEa8GkM6uOKnwWV8X1uxe8iur-_wVygNVnCf0w7XR8DfYZwp6wK54Jucpv1L9Kx3Q4FXp_cCrT-svl1_7O6-3Hy6vrrrPF-a2ilpRFDcbTaGaemN5p4ER6ky2iiz5CCcYFozcIRtesOXUgTdtwEVgAvgF-jtkbvP6ccEpdpdLB6GwY2QpmI1lUJrRVuQHYM-p1Iy9Haf487l35YSO6u2WzurtrPq-dZUt9KbE33a7CD8q5zctsD7YwDaHw8Rsi3-r9YQM_hqQ4r_4_8BGZ2QNg</recordid><startdate>2004</startdate><enddate>2004</enddate><creator>Hinchliffe, R.J</creator><creator>Goldberg, J</creator><creator>MacSweeney, S.T.R</creator><creator>On behalf of the Zenith Users Group</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>2004</creationdate><title>A UK Multi-centre Experience with a Second-generation Endovascular Stent-graft: Results from the Zenith Users Group</title><author>Hinchliffe, R.J ; Goldberg, J ; MacSweeney, S.T.R ; On behalf of the Zenith Users Group</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c398t-6584d63abb8275c873c0da1168786893e4a42772ea02bf83954d7f7f7e6de34e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Abdominal aortic aneurysm</topic><topic>Aged</topic><topic>Aortic Aneurysm, Abdominal - surgery</topic><topic>Blood Vessel Prosthesis</topic><topic>Endovascular aneurysm repair</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Prosthesis Design</topic><topic>Stents</topic><topic>Treatment Outcome</topic><topic>Zenith stent-graft</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hinchliffe, R.J</creatorcontrib><creatorcontrib>Goldberg, J</creatorcontrib><creatorcontrib>MacSweeney, S.T.R</creatorcontrib><creatorcontrib>On behalf of the Zenith Users Group</creatorcontrib><creatorcontrib>Zenith Users Group</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of vascular and endovascular surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hinchliffe, R.J</au><au>Goldberg, J</au><au>MacSweeney, S.T.R</au><au>On behalf of the Zenith Users Group</au><aucorp>Zenith Users Group</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A UK Multi-centre Experience with a Second-generation Endovascular Stent-graft: Results from the Zenith Users Group</atitle><jtitle>European journal of vascular and endovascular surgery</jtitle><addtitle>Eur J Vasc Endovasc Surg</addtitle><date>2004</date><risdate>2004</risdate><volume>27</volume><issue>1</issue><spage>51</spage><epage>55</epage><pages>51-55</pages><issn>1078-5884</issn><eissn>1532-2165</eissn><abstract>Background. Endovascular aneurysm repair has been criticised for high rates of technical failure and secondary intervention. Second generation stent-grafts have been developed in an attempt to reduce these problems. The results of a UK multi-centre experience with a second generation device (Zenith) are presented.
Methods. Data were collected retrospectively from five experienced UK vascular centres in patients undergoing endovascular aneurysm repair with the Zenith stent-graft.
Results. A total of 269 patients underwent attempted aneurysm repair with the Zenith device. Median aneurysm diameter was 65 (interquartile range 52–78)
mm. There were no conversions to open repair. Peri-operative mortality was 4.1% (11/269). On the initial post-operative scan, 94.1% of aneurysms were successfully excluded. During a median follow-up of 363 (interquartile range 154–720) days there were 19 secondary interventions and two aneurysm ruptures.
Conclusions. Second generation endovascular stent-graft designs such as the Zenith are associated with low rates of intra-operative technical complications. Few secondary interventions have been necessary during follow-up; however, surveillance is essential to ensure they continue to perform.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>14652837</pmid><doi>10.1016/j.ejvs.2003.10.004</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1078-5884 |
ispartof | European journal of vascular and endovascular surgery, 2004, Vol.27 (1), p.51-55 |
issn | 1078-5884 1532-2165 |
language | eng |
recordid | cdi_proquest_miscellaneous_71547761 |
source | Elsevier |
subjects | Abdominal aortic aneurysm Aged Aortic Aneurysm, Abdominal - surgery Blood Vessel Prosthesis Endovascular aneurysm repair Female Humans Male Prosthesis Design Stents Treatment Outcome Zenith stent-graft |
title | A UK Multi-centre Experience with a Second-generation Endovascular Stent-graft: Results from the Zenith Users Group |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T09%3A37%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20UK%20Multi-centre%20Experience%20with%20a%20Second-generation%20Endovascular%20Stent-graft:%20Results%20from%20the%20Zenith%20Users%20Group&rft.jtitle=European%20journal%20of%20vascular%20and%20endovascular%20surgery&rft.au=Hinchliffe,%20R.J&rft.aucorp=Zenith%20Users%20Group&rft.date=2004&rft.volume=27&rft.issue=1&rft.spage=51&rft.epage=55&rft.pages=51-55&rft.issn=1078-5884&rft.eissn=1532-2165&rft_id=info:doi/10.1016/j.ejvs.2003.10.004&rft_dat=%3Cproquest_cross%3E71547761%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c398t-6584d63abb8275c873c0da1168786893e4a42772ea02bf83954d7f7f7e6de34e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=71547761&rft_id=info:pmid/14652837&rfr_iscdi=true |