Loading…
In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast
A high-resolution spin-echo imaging method is presented (called CP-LASER) which exploits the spin refocusing capability of an adiabatic Carr-Purcell (CP) pulse sequence to measure apparent 1H2O transverse relaxation (T2+) and generate contrast based on microscopic tissue susceptibility. High-resolut...
Saved in:
Published in: | Magnetic resonance in medicine 2002-04, Vol.47 (4), p.742-750 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 750 |
container_issue | 4 |
container_start_page | 742 |
container_title | Magnetic resonance in medicine |
container_volume | 47 |
creator | Bartha, Robert Michaeli, Shalom Merkle, Hellmut Adriany, Gregor Andersen, Peter Chen, Wei Ugurbil, Kamil Garwood, Michael |
description | A high-resolution spin-echo imaging method is presented (called CP-LASER) which exploits the spin refocusing capability of an adiabatic Carr-Purcell (CP) pulse sequence to measure apparent 1H2O transverse relaxation (T2+) and generate contrast based on microscopic tissue susceptibility. High-resolution CP-LASER images of the human occipital lobe were acquired at four different echo times from six subjects at 4T and eight subjects at 7T to investigate the effect of magnetic field strength (B(0)) and the CP interpulse time (tau(cp)) on T2+. Susceptibility contrast was identified and T2+ was quantified for long tau(cp) (>10 ms) and short tau(cp) (7 ms at 4T and 6 ms at 7T) in gray matter, white matter, and cerebral spinal fluid. The 1H2O relaxation rate constants (1/T2+) of gray and white matter each increased approximately linearly with field strength and T2+ was inversely related to tau(cp). The average T2+ value of gray matter was 19% and 9% smaller than that of white matter at 4T and 7T, respectively. These results are consistent with higher levels of compartmentalized ferritin and increased blood volume in gray matter compared to white matter in this region of the brain. |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_71589053</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>71589053</sourcerecordid><originalsourceid>FETCH-LOGICAL-p546-51c6e0bbf5c43abe28c4d55488150435ff697b58c69204079e658884933ea9f13</originalsourceid><addsrcrecordid>eNo1kMFKxDAYhHtQ3HX1FeQ_eZFC2iRt4k0WdRdWVqT3kqR_2Ujb1CRd6DP40q64ngaGb4ZhLpIlKRlJaSbZIrkO4ZMQImXJrpJFdvJESYtl8r0d4GiPDrJNvocqf4AeVZg89jhEsAPEA8Jh6tUAzhg72qg66JxGUBFYBWpooKxAz7BW3qfvkzfYdfD2sX2EBiOaaN0p2kJvjXfBuNEaCFMwOEarbWfjDMYN0asQb5LLVnUBb8-6SqqX52q9SXf71-36aZeOnBUpz0yBROuWG0aVxlwY1nDOhMg4YZS3bSFLzYUpZE4YKSUWXAjBJKWoZJvRVXL_Vzt69zVhiHVvw-9qNaCbQl1mXEjC6Qm8O4OT7rGpR2975ef6_z36A4Qaac4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71589053</pqid></control><display><type>article</type><title>In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast</title><source>Wiley-Blackwell Read & Publish Collection</source><creator>Bartha, Robert ; Michaeli, Shalom ; Merkle, Hellmut ; Adriany, Gregor ; Andersen, Peter ; Chen, Wei ; Ugurbil, Kamil ; Garwood, Michael</creator><creatorcontrib>Bartha, Robert ; Michaeli, Shalom ; Merkle, Hellmut ; Adriany, Gregor ; Andersen, Peter ; Chen, Wei ; Ugurbil, Kamil ; Garwood, Michael</creatorcontrib><description>A high-resolution spin-echo imaging method is presented (called CP-LASER) which exploits the spin refocusing capability of an adiabatic Carr-Purcell (CP) pulse sequence to measure apparent 1H2O transverse relaxation (T2+) and generate contrast based on microscopic tissue susceptibility. High-resolution CP-LASER images of the human occipital lobe were acquired at four different echo times from six subjects at 4T and eight subjects at 7T to investigate the effect of magnetic field strength (B(0)) and the CP interpulse time (tau(cp)) on T2+. Susceptibility contrast was identified and T2+ was quantified for long tau(cp) (>10 ms) and short tau(cp) (7 ms at 4T and 6 ms at 7T) in gray matter, white matter, and cerebral spinal fluid. The 1H2O relaxation rate constants (1/T2+) of gray and white matter each increased approximately linearly with field strength and T2+ was inversely related to tau(cp). The average T2+ value of gray matter was 19% and 9% smaller than that of white matter at 4T and 7T, respectively. These results are consistent with higher levels of compartmentalized ferritin and increased blood volume in gray matter compared to white matter in this region of the brain.</description><identifier>ISSN: 0740-3194</identifier><identifier>PMID: 11948736</identifier><language>eng</language><publisher>United States</publisher><subject>Body Water ; Humans ; Magnetic Resonance Imaging - methods ; Magnetic Resonance Spectroscopy ; Occipital Lobe - anatomy & histology</subject><ispartof>Magnetic resonance in medicine, 2002-04, Vol.47 (4), p.742-750</ispartof><rights>Copyright 2002 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11948736$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bartha, Robert</creatorcontrib><creatorcontrib>Michaeli, Shalom</creatorcontrib><creatorcontrib>Merkle, Hellmut</creatorcontrib><creatorcontrib>Adriany, Gregor</creatorcontrib><creatorcontrib>Andersen, Peter</creatorcontrib><creatorcontrib>Chen, Wei</creatorcontrib><creatorcontrib>Ugurbil, Kamil</creatorcontrib><creatorcontrib>Garwood, Michael</creatorcontrib><title>In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast</title><title>Magnetic resonance in medicine</title><addtitle>Magn Reson Med</addtitle><description>A high-resolution spin-echo imaging method is presented (called CP-LASER) which exploits the spin refocusing capability of an adiabatic Carr-Purcell (CP) pulse sequence to measure apparent 1H2O transverse relaxation (T2+) and generate contrast based on microscopic tissue susceptibility. High-resolution CP-LASER images of the human occipital lobe were acquired at four different echo times from six subjects at 4T and eight subjects at 7T to investigate the effect of magnetic field strength (B(0)) and the CP interpulse time (tau(cp)) on T2+. Susceptibility contrast was identified and T2+ was quantified for long tau(cp) (>10 ms) and short tau(cp) (7 ms at 4T and 6 ms at 7T) in gray matter, white matter, and cerebral spinal fluid. The 1H2O relaxation rate constants (1/T2+) of gray and white matter each increased approximately linearly with field strength and T2+ was inversely related to tau(cp). The average T2+ value of gray matter was 19% and 9% smaller than that of white matter at 4T and 7T, respectively. These results are consistent with higher levels of compartmentalized ferritin and increased blood volume in gray matter compared to white matter in this region of the brain.</description><subject>Body Water</subject><subject>Humans</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Magnetic Resonance Spectroscopy</subject><subject>Occipital Lobe - anatomy & histology</subject><issn>0740-3194</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNo1kMFKxDAYhHtQ3HX1FeQ_eZFC2iRt4k0WdRdWVqT3kqR_2Ujb1CRd6DP40q64ngaGb4ZhLpIlKRlJaSbZIrkO4ZMQImXJrpJFdvJESYtl8r0d4GiPDrJNvocqf4AeVZg89jhEsAPEA8Jh6tUAzhg72qg66JxGUBFYBWpooKxAz7BW3qfvkzfYdfD2sX2EBiOaaN0p2kJvjXfBuNEaCFMwOEarbWfjDMYN0asQb5LLVnUBb8-6SqqX52q9SXf71-36aZeOnBUpz0yBROuWG0aVxlwY1nDOhMg4YZS3bSFLzYUpZE4YKSUWXAjBJKWoZJvRVXL_Vzt69zVhiHVvw-9qNaCbQl1mXEjC6Qm8O4OT7rGpR2975ef6_z36A4Qaac4</recordid><startdate>200204</startdate><enddate>200204</enddate><creator>Bartha, Robert</creator><creator>Michaeli, Shalom</creator><creator>Merkle, Hellmut</creator><creator>Adriany, Gregor</creator><creator>Andersen, Peter</creator><creator>Chen, Wei</creator><creator>Ugurbil, Kamil</creator><creator>Garwood, Michael</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>200204</creationdate><title>In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast</title><author>Bartha, Robert ; Michaeli, Shalom ; Merkle, Hellmut ; Adriany, Gregor ; Andersen, Peter ; Chen, Wei ; Ugurbil, Kamil ; Garwood, Michael</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p546-51c6e0bbf5c43abe28c4d55488150435ff697b58c69204079e658884933ea9f13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Body Water</topic><topic>Humans</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Magnetic Resonance Spectroscopy</topic><topic>Occipital Lobe - anatomy & histology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bartha, Robert</creatorcontrib><creatorcontrib>Michaeli, Shalom</creatorcontrib><creatorcontrib>Merkle, Hellmut</creatorcontrib><creatorcontrib>Adriany, Gregor</creatorcontrib><creatorcontrib>Andersen, Peter</creatorcontrib><creatorcontrib>Chen, Wei</creatorcontrib><creatorcontrib>Ugurbil, Kamil</creatorcontrib><creatorcontrib>Garwood, Michael</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bartha, Robert</au><au>Michaeli, Shalom</au><au>Merkle, Hellmut</au><au>Adriany, Gregor</au><au>Andersen, Peter</au><au>Chen, Wei</au><au>Ugurbil, Kamil</au><au>Garwood, Michael</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn Reson Med</addtitle><date>2002-04</date><risdate>2002</risdate><volume>47</volume><issue>4</issue><spage>742</spage><epage>750</epage><pages>742-750</pages><issn>0740-3194</issn><abstract>A high-resolution spin-echo imaging method is presented (called CP-LASER) which exploits the spin refocusing capability of an adiabatic Carr-Purcell (CP) pulse sequence to measure apparent 1H2O transverse relaxation (T2+) and generate contrast based on microscopic tissue susceptibility. High-resolution CP-LASER images of the human occipital lobe were acquired at four different echo times from six subjects at 4T and eight subjects at 7T to investigate the effect of magnetic field strength (B(0)) and the CP interpulse time (tau(cp)) on T2+. Susceptibility contrast was identified and T2+ was quantified for long tau(cp) (>10 ms) and short tau(cp) (7 ms at 4T and 6 ms at 7T) in gray matter, white matter, and cerebral spinal fluid. The 1H2O relaxation rate constants (1/T2+) of gray and white matter each increased approximately linearly with field strength and T2+ was inversely related to tau(cp). The average T2+ value of gray matter was 19% and 9% smaller than that of white matter at 4T and 7T, respectively. These results are consistent with higher levels of compartmentalized ferritin and increased blood volume in gray matter compared to white matter in this region of the brain.</abstract><cop>United States</cop><pmid>11948736</pmid><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0740-3194 |
ispartof | Magnetic resonance in medicine, 2002-04, Vol.47 (4), p.742-750 |
issn | 0740-3194 |
language | eng |
recordid | cdi_proquest_miscellaneous_71589053 |
source | Wiley-Blackwell Read & Publish Collection |
subjects | Body Water Humans Magnetic Resonance Imaging - methods Magnetic Resonance Spectroscopy Occipital Lobe - anatomy & histology |
title | In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T05%3A48%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20vivo%201H2O%20T2+%20measurement%20in%20the%20human%20occipital%20lobe%20at%204T%20and%207T%20by%20Carr-Purcell%20MRI:%20detection%20of%20microscopic%20susceptibility%20contrast&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Bartha,%20Robert&rft.date=2002-04&rft.volume=47&rft.issue=4&rft.spage=742&rft.epage=750&rft.pages=742-750&rft.issn=0740-3194&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E71589053%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p546-51c6e0bbf5c43abe28c4d55488150435ff697b58c69204079e658884933ea9f13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=71589053&rft_id=info:pmid/11948736&rfr_iscdi=true |