Loading…
Measurement of density variations in tablets using X-ray computed tomography
In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values p...
Saved in:
Published in: | International journal of pharmaceutics 2004-03, Vol.271 (1), p.215-224 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113 |
---|---|
cites | cdi_FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113 |
container_end_page | 224 |
container_issue | 1 |
container_start_page | 215 |
container_title | International journal of pharmaceutics |
container_volume | 271 |
creator | Sinka, I.C. Burch, S.F. Tweed, J.H. Cunningham, J.C. |
description | In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and “beam hardening”. Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features. |
doi_str_mv | 10.1016/j.ijpharm.2003.11.022 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71903321</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378517303006276</els_id><sourcerecordid>71903321</sourcerecordid><originalsourceid>FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113</originalsourceid><addsrcrecordid>eNqF0E2L1TAUgOEginMd_QlKNrprzUn6kaxEBr_gihsFd-E0PZ3JpW1qkg7cf2-HW9DdrELgOSfhZew1iBIENO9PpT8tdxinUgqhSoBSSPmEHUC3qlBV2zxlB6FaXdTQqiv2IqWTEKKRoJ6zK6hBGqP1gR2_E6Y10kRz5mHgPc3J5zO_x-gx-zAn7meesRspJ74mP9_y30XEM3dhWtZMPc9hCrcRl7vzS_ZswDHRq_28Zr8-f_p587U4_vjy7ebjsXCV1rmQbd2jcQRNUzWEXV0jOTCIjXQDIkA3kDNUDaYhtV2d1E3XqmHTyrUA6pq9u-xdYvizUsp28snROOJMYU22BSOUko9DMEaCrPQG6wt0MaQUabBL9BPGswVhH3rbk91724feFsBuvbe5N_sDazdR_29qD7yBtzvA5HAcIs7Op_9cpSuAenMfLo62bveeok3O0-yo95Fctn3wj3zlL5Nxoe8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19921248</pqid></control><display><type>article</type><title>Measurement of density variations in tablets using X-ray computed tomography</title><source>ScienceDirect Freedom Collection</source><creator>Sinka, I.C. ; Burch, S.F. ; Tweed, J.H. ; Cunningham, J.C.</creator><creatorcontrib>Sinka, I.C. ; Burch, S.F. ; Tweed, J.H. ; Cunningham, J.C.</creatorcontrib><description>In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and “beam hardening”. Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features.</description><identifier>ISSN: 0378-5173</identifier><identifier>EISSN: 1873-3476</identifier><identifier>DOI: 10.1016/j.ijpharm.2003.11.022</identifier><identifier>PMID: 15129988</identifier><identifier>CODEN: IJPHDE</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Biological and medical sciences ; Cellulose - chemistry ; Density distribution ; General pharmacology ; Medical sciences ; Pharmaceutical technology. Pharmaceutical industry ; Pharmacology. Drug treatments ; Tablet ; Tablets - chemistry ; Tomography, X-Ray Computed ; X-ray computed tomography</subject><ispartof>International journal of pharmaceutics, 2004-03, Vol.271 (1), p.215-224</ispartof><rights>2003 Elsevier B.V.</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113</citedby><cites>FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=15484115$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15129988$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sinka, I.C.</creatorcontrib><creatorcontrib>Burch, S.F.</creatorcontrib><creatorcontrib>Tweed, J.H.</creatorcontrib><creatorcontrib>Cunningham, J.C.</creatorcontrib><title>Measurement of density variations in tablets using X-ray computed tomography</title><title>International journal of pharmaceutics</title><addtitle>Int J Pharm</addtitle><description>In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and “beam hardening”. Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features.</description><subject>Biological and medical sciences</subject><subject>Cellulose - chemistry</subject><subject>Density distribution</subject><subject>General pharmacology</subject><subject>Medical sciences</subject><subject>Pharmaceutical technology. Pharmaceutical industry</subject><subject>Pharmacology. Drug treatments</subject><subject>Tablet</subject><subject>Tablets - chemistry</subject><subject>Tomography, X-Ray Computed</subject><subject>X-ray computed tomography</subject><issn>0378-5173</issn><issn>1873-3476</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqF0E2L1TAUgOEginMd_QlKNrprzUn6kaxEBr_gihsFd-E0PZ3JpW1qkg7cf2-HW9DdrELgOSfhZew1iBIENO9PpT8tdxinUgqhSoBSSPmEHUC3qlBV2zxlB6FaXdTQqiv2IqWTEKKRoJ6zK6hBGqP1gR2_E6Y10kRz5mHgPc3J5zO_x-gx-zAn7meesRspJ74mP9_y30XEM3dhWtZMPc9hCrcRl7vzS_ZswDHRq_28Zr8-f_p587U4_vjy7ebjsXCV1rmQbd2jcQRNUzWEXV0jOTCIjXQDIkA3kDNUDaYhtV2d1E3XqmHTyrUA6pq9u-xdYvizUsp28snROOJMYU22BSOUko9DMEaCrPQG6wt0MaQUabBL9BPGswVhH3rbk91724feFsBuvbe5N_sDazdR_29qD7yBtzvA5HAcIs7Op_9cpSuAenMfLo62bveeok3O0-yo95Fctn3wj3zlL5Nxoe8</recordid><startdate>20040301</startdate><enddate>20040301</enddate><creator>Sinka, I.C.</creator><creator>Burch, S.F.</creator><creator>Tweed, J.H.</creator><creator>Cunningham, J.C.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20040301</creationdate><title>Measurement of density variations in tablets using X-ray computed tomography</title><author>Sinka, I.C. ; Burch, S.F. ; Tweed, J.H. ; Cunningham, J.C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Biological and medical sciences</topic><topic>Cellulose - chemistry</topic><topic>Density distribution</topic><topic>General pharmacology</topic><topic>Medical sciences</topic><topic>Pharmaceutical technology. Pharmaceutical industry</topic><topic>Pharmacology. Drug treatments</topic><topic>Tablet</topic><topic>Tablets - chemistry</topic><topic>Tomography, X-Ray Computed</topic><topic>X-ray computed tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sinka, I.C.</creatorcontrib><creatorcontrib>Burch, S.F.</creatorcontrib><creatorcontrib>Tweed, J.H.</creatorcontrib><creatorcontrib>Cunningham, J.C.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of pharmaceutics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sinka, I.C.</au><au>Burch, S.F.</au><au>Tweed, J.H.</au><au>Cunningham, J.C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurement of density variations in tablets using X-ray computed tomography</atitle><jtitle>International journal of pharmaceutics</jtitle><addtitle>Int J Pharm</addtitle><date>2004-03-01</date><risdate>2004</risdate><volume>271</volume><issue>1</issue><spage>215</spage><epage>224</epage><pages>215-224</pages><issn>0378-5173</issn><eissn>1873-3476</eissn><coden>IJPHDE</coden><abstract>In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and “beam hardening”. Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>15129988</pmid><doi>10.1016/j.ijpharm.2003.11.022</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0378-5173 |
ispartof | International journal of pharmaceutics, 2004-03, Vol.271 (1), p.215-224 |
issn | 0378-5173 1873-3476 |
language | eng |
recordid | cdi_proquest_miscellaneous_71903321 |
source | ScienceDirect Freedom Collection |
subjects | Biological and medical sciences Cellulose - chemistry Density distribution General pharmacology Medical sciences Pharmaceutical technology. Pharmaceutical industry Pharmacology. Drug treatments Tablet Tablets - chemistry Tomography, X-Ray Computed X-ray computed tomography |
title | Measurement of density variations in tablets using X-ray computed tomography |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T14%3A34%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurement%20of%20density%20variations%20in%20tablets%20using%20X-ray%20computed%20tomography&rft.jtitle=International%20journal%20of%20pharmaceutics&rft.au=Sinka,%20I.C.&rft.date=2004-03-01&rft.volume=271&rft.issue=1&rft.spage=215&rft.epage=224&rft.pages=215-224&rft.issn=0378-5173&rft.eissn=1873-3476&rft.coden=IJPHDE&rft_id=info:doi/10.1016/j.ijpharm.2003.11.022&rft_dat=%3Cproquest_cross%3E71903321%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=19921248&rft_id=info:pmid/15129988&rfr_iscdi=true |