Measurement of density variations in tablets using X-ray computed tomography

In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values p...

Full description

Saved in:
Bibliographic Details
Published in:International journal of pharmaceutics 2004-03, Vol.271 (1), p.215-224
Main Authors: Sinka, I.C., Burch, S.F., Tweed, J.H., Cunningham, J.C.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113
cites cdi_FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113
container_end_page 224
container_issue 1
container_start_page 215
container_title International journal of pharmaceutics
container_volume 271
creator Sinka, I.C.
Burch, S.F.
Tweed, J.H.
Cunningham, J.C.
description In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and “beam hardening”. Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features.
doi_str_mv 10.1016/j.ijpharm.2003.11.022
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71903321</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378517303006276</els_id><sourcerecordid>71903321</sourcerecordid><originalsourceid>FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113</originalsourceid><addsrcrecordid>eNqF0E2L1TAUgOEginMd_QlKNrprzUn6kaxEBr_gihsFd-E0PZ3JpW1qkg7cf2-HW9DdrELgOSfhZew1iBIENO9PpT8tdxinUgqhSoBSSPmEHUC3qlBV2zxlB6FaXdTQqiv2IqWTEKKRoJ6zK6hBGqP1gR2_E6Y10kRz5mHgPc3J5zO_x-gx-zAn7meesRspJ74mP9_y30XEM3dhWtZMPc9hCrcRl7vzS_ZswDHRq_28Zr8-f_p587U4_vjy7ebjsXCV1rmQbd2jcQRNUzWEXV0jOTCIjXQDIkA3kDNUDaYhtV2d1E3XqmHTyrUA6pq9u-xdYvizUsp28snROOJMYU22BSOUko9DMEaCrPQG6wt0MaQUabBL9BPGswVhH3rbk91724feFsBuvbe5N_sDazdR_29qD7yBtzvA5HAcIs7Op_9cpSuAenMfLo62bveeok3O0-yo95Fctn3wj3zlL5Nxoe8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19921248</pqid></control><display><type>article</type><title>Measurement of density variations in tablets using X-ray computed tomography</title><source>ScienceDirect Freedom Collection</source><creator>Sinka, I.C. ; Burch, S.F. ; Tweed, J.H. ; Cunningham, J.C.</creator><creatorcontrib>Sinka, I.C. ; Burch, S.F. ; Tweed, J.H. ; Cunningham, J.C.</creatorcontrib><description>In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and “beam hardening”. Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features.</description><identifier>ISSN: 0378-5173</identifier><identifier>EISSN: 1873-3476</identifier><identifier>DOI: 10.1016/j.ijpharm.2003.11.022</identifier><identifier>PMID: 15129988</identifier><identifier>CODEN: IJPHDE</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Biological and medical sciences ; Cellulose - chemistry ; Density distribution ; General pharmacology ; Medical sciences ; Pharmaceutical technology. Pharmaceutical industry ; Pharmacology. Drug treatments ; Tablet ; Tablets - chemistry ; Tomography, X-Ray Computed ; X-ray computed tomography</subject><ispartof>International journal of pharmaceutics, 2004-03, Vol.271 (1), p.215-224</ispartof><rights>2003 Elsevier B.V.</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113</citedby><cites>FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=15484115$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15129988$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sinka, I.C.</creatorcontrib><creatorcontrib>Burch, S.F.</creatorcontrib><creatorcontrib>Tweed, J.H.</creatorcontrib><creatorcontrib>Cunningham, J.C.</creatorcontrib><title>Measurement of density variations in tablets using X-ray computed tomography</title><title>International journal of pharmaceutics</title><addtitle>Int J Pharm</addtitle><description>In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and “beam hardening”. Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features.</description><subject>Biological and medical sciences</subject><subject>Cellulose - chemistry</subject><subject>Density distribution</subject><subject>General pharmacology</subject><subject>Medical sciences</subject><subject>Pharmaceutical technology. Pharmaceutical industry</subject><subject>Pharmacology. Drug treatments</subject><subject>Tablet</subject><subject>Tablets - chemistry</subject><subject>Tomography, X-Ray Computed</subject><subject>X-ray computed tomography</subject><issn>0378-5173</issn><issn>1873-3476</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqF0E2L1TAUgOEginMd_QlKNrprzUn6kaxEBr_gihsFd-E0PZ3JpW1qkg7cf2-HW9DdrELgOSfhZew1iBIENO9PpT8tdxinUgqhSoBSSPmEHUC3qlBV2zxlB6FaXdTQqiv2IqWTEKKRoJ6zK6hBGqP1gR2_E6Y10kRz5mHgPc3J5zO_x-gx-zAn7meesRspJ74mP9_y30XEM3dhWtZMPc9hCrcRl7vzS_ZswDHRq_28Zr8-f_p587U4_vjy7ebjsXCV1rmQbd2jcQRNUzWEXV0jOTCIjXQDIkA3kDNUDaYhtV2d1E3XqmHTyrUA6pq9u-xdYvizUsp28snROOJMYU22BSOUko9DMEaCrPQG6wt0MaQUabBL9BPGswVhH3rbk91724feFsBuvbe5N_sDazdR_29qD7yBtzvA5HAcIs7Op_9cpSuAenMfLo62bveeok3O0-yo95Fctn3wj3zlL5Nxoe8</recordid><startdate>20040301</startdate><enddate>20040301</enddate><creator>Sinka, I.C.</creator><creator>Burch, S.F.</creator><creator>Tweed, J.H.</creator><creator>Cunningham, J.C.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20040301</creationdate><title>Measurement of density variations in tablets using X-ray computed tomography</title><author>Sinka, I.C. ; Burch, S.F. ; Tweed, J.H. ; Cunningham, J.C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Biological and medical sciences</topic><topic>Cellulose - chemistry</topic><topic>Density distribution</topic><topic>General pharmacology</topic><topic>Medical sciences</topic><topic>Pharmaceutical technology. Pharmaceutical industry</topic><topic>Pharmacology. Drug treatments</topic><topic>Tablet</topic><topic>Tablets - chemistry</topic><topic>Tomography, X-Ray Computed</topic><topic>X-ray computed tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sinka, I.C.</creatorcontrib><creatorcontrib>Burch, S.F.</creatorcontrib><creatorcontrib>Tweed, J.H.</creatorcontrib><creatorcontrib>Cunningham, J.C.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of pharmaceutics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sinka, I.C.</au><au>Burch, S.F.</au><au>Tweed, J.H.</au><au>Cunningham, J.C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurement of density variations in tablets using X-ray computed tomography</atitle><jtitle>International journal of pharmaceutics</jtitle><addtitle>Int J Pharm</addtitle><date>2004-03-01</date><risdate>2004</risdate><volume>271</volume><issue>1</issue><spage>215</spage><epage>224</epage><pages>215-224</pages><issn>0378-5173</issn><eissn>1873-3476</eissn><coden>IJPHDE</coden><abstract>In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed. X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and “beam hardening”. Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>15129988</pmid><doi>10.1016/j.ijpharm.2003.11.022</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-5173
ispartof International journal of pharmaceutics, 2004-03, Vol.271 (1), p.215-224
issn 0378-5173
1873-3476
language eng
recordid cdi_proquest_miscellaneous_71903321
source ScienceDirect Freedom Collection
subjects Biological and medical sciences
Cellulose - chemistry
Density distribution
General pharmacology
Medical sciences
Pharmaceutical technology. Pharmaceutical industry
Pharmacology. Drug treatments
Tablet
Tablets - chemistry
Tomography, X-Ray Computed
X-ray computed tomography
title Measurement of density variations in tablets using X-ray computed tomography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T14%3A34%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurement%20of%20density%20variations%20in%20tablets%20using%20X-ray%20computed%20tomography&rft.jtitle=International%20journal%20of%20pharmaceutics&rft.au=Sinka,%20I.C.&rft.date=2004-03-01&rft.volume=271&rft.issue=1&rft.spage=215&rft.epage=224&rft.pages=215-224&rft.issn=0378-5173&rft.eissn=1873-3476&rft.coden=IJPHDE&rft_id=info:doi/10.1016/j.ijpharm.2003.11.022&rft_dat=%3Cproquest_cross%3E71903321%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c488t-275da9ce16646eab55aec19aa62cfaa11bfec9e4f96e3a11c286b73f6463c7113%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=19921248&rft_id=info:pmid/15129988&rfr_iscdi=true