Loading…

Relation of the static compliance curve and Positive end-expiratory pressure to oxygenation during one-lung ventilation

Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (PaO(2)) to decrease further. The current study examined whether the effe...

Full description

Saved in:
Bibliographic Details
Published in:Anesthesiology (Philadelphia) 2001-11, Vol.95 (5), p.1096-1102
Main Authors: SLINGER, Peter D, KRUGER, Marelise, MCRAE, Karen, WINTON, Timothy
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c323t-c87626ff8bbf4396373efcded755b41028a5df228e1d149e5648a9f4323d2eed3
cites
container_end_page 1102
container_issue 5
container_start_page 1096
container_title Anesthesiology (Philadelphia)
container_volume 95
creator SLINGER, Peter D
KRUGER, Marelise
MCRAE, Karen
WINTON, Timothy
description Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (PaO(2)) to decrease further. The current study examined whether the effects of PEEP on oxygenation depend on the static compliance curve of the lung to which it is applied. Forty-two adults undergoing thoracic surgery were studied during stable, open-chest, one-lung ventilation. Arterial blood gases were measured during two-lung ventilation and one-lung ventilation before, during, and after the application of 5 cm H(2)O PEEP to the ventilated lung. The plateau end-expiratory pressure and static compliance curve of the ventilated lung were measured with and without applied PEEP, and the lower inflection point was determined from the compliance curve. Mean (+/- SD) PaO(2) values, with a fraction of inspired oxygen of 1.0, were not different during one-lung ventilation before (192 +/- 91 mmHg), during (190 +/- 90), or after ( 205 +/- 79) the addition of 5 cm H(2)O PEEP. The mean plateau end-expiratory pressure increased from 4.2 to 6.8 cm H(2)O with the application of 5 cm H(2)O PEEP and decreased to 4.5 cm H(2)O when 5 cm H(2)O PEEP was removed. Six patients showed a clinically useful (> 20%) increase in PaO(2) with 5 cm H(2)O PEEP, and nine patients had a greater than 20% decrease in PaO(2). The change in PaO(2) with the application of 5 cm H(2)O PEEP correlated in an inverse fashion with the change in the gradient between the end-expiratory pressure and the pressure at the lower inflection point (r = 0.76). The subgroup of patients with a PaO(2) during two-lung ventilation that was less than the mean (365 mmHg) and an end-expiratory pressure during one-lung ventilation without applied PEEP less than the mean were more likely to have an increase in PaO(2) when 5 cm H(2)O PEEP was applied. The effects of the application of external 5 cm H(2)O PEEP on oxygenation during one-lung ventilation correspond to individual changes in the relation between the plateau end-expiratory pressure and the inflection point of the static compliance curve. When the application of PEEP causes the end-expiratory pressure to increase from a low level toward the inflection point, oxygenation is likely to improve. Conversely, if the addition of PEEP causes an increased inflation of the ventilated lung that raises the equilibrium end-expiratory pressure beyond
doi_str_mv 10.1097/00000542-200111000-00012
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72237167</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72237167</sourcerecordid><originalsourceid>FETCH-LOGICAL-c323t-c87626ff8bbf4396373efcded755b41028a5df228e1d149e5648a9f4323d2eed3</originalsourceid><addsrcrecordid>eNpFkF1PHCEUhompcdfVv9Bw095h-ZgZmMvG1GpiUmP0esLCwdLMwhQYu_vvi-62S0I4L3nOOcmDEGb0itFefqFvp2044ZQyxmog9TJ-gpas5YowJtsPaFn_BBGU8wU6z_lXjbIV6gwtGOtU00u5RH8eYdTFx4Cjw-Un4FxqNNjEzTR6HQxgM6dXwDpY_BCzL74GCJbAdvJJl5h2eEqQ85wAl4jjdvcCYT_SzsmHFxwDkHGuxSuE4vfrLtCp02OGy8O7Qs83356ub8n9j-9311_viRFcFGKU7HjnnFqvXSP6TkgBzliwsm3XDaNc6dY6zhUwy5oe2q5Ruq8oF5YDWLFCn_dzpxR_z5DLsPHZwDjqAHHOg-RcSNbJCqo9aFLMOYEbpuQ3Ou0GRoc36cM_6cN_6cO79Nr68bBjXm_AHhsPlivw6QDobPToUvXq85FrqOI9bcRfkPSMUQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72237167</pqid></control><display><type>article</type><title>Relation of the static compliance curve and Positive end-expiratory pressure to oxygenation during one-lung ventilation</title><source>HEAL-Link subscriptions: Lippincott Williams &amp; Wilkins</source><creator>SLINGER, Peter D ; KRUGER, Marelise ; MCRAE, Karen ; WINTON, Timothy</creator><creatorcontrib>SLINGER, Peter D ; KRUGER, Marelise ; MCRAE, Karen ; WINTON, Timothy</creatorcontrib><description>Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (PaO(2)) to decrease further. The current study examined whether the effects of PEEP on oxygenation depend on the static compliance curve of the lung to which it is applied. Forty-two adults undergoing thoracic surgery were studied during stable, open-chest, one-lung ventilation. Arterial blood gases were measured during two-lung ventilation and one-lung ventilation before, during, and after the application of 5 cm H(2)O PEEP to the ventilated lung. The plateau end-expiratory pressure and static compliance curve of the ventilated lung were measured with and without applied PEEP, and the lower inflection point was determined from the compliance curve. Mean (+/- SD) PaO(2) values, with a fraction of inspired oxygen of 1.0, were not different during one-lung ventilation before (192 +/- 91 mmHg), during (190 +/- 90), or after ( 205 +/- 79) the addition of 5 cm H(2)O PEEP. The mean plateau end-expiratory pressure increased from 4.2 to 6.8 cm H(2)O with the application of 5 cm H(2)O PEEP and decreased to 4.5 cm H(2)O when 5 cm H(2)O PEEP was removed. Six patients showed a clinically useful (&gt; 20%) increase in PaO(2) with 5 cm H(2)O PEEP, and nine patients had a greater than 20% decrease in PaO(2). The change in PaO(2) with the application of 5 cm H(2)O PEEP correlated in an inverse fashion with the change in the gradient between the end-expiratory pressure and the pressure at the lower inflection point (r = 0.76). The subgroup of patients with a PaO(2) during two-lung ventilation that was less than the mean (365 mmHg) and an end-expiratory pressure during one-lung ventilation without applied PEEP less than the mean were more likely to have an increase in PaO(2) when 5 cm H(2)O PEEP was applied. The effects of the application of external 5 cm H(2)O PEEP on oxygenation during one-lung ventilation correspond to individual changes in the relation between the plateau end-expiratory pressure and the inflection point of the static compliance curve. When the application of PEEP causes the end-expiratory pressure to increase from a low level toward the inflection point, oxygenation is likely to improve. Conversely, if the addition of PEEP causes an increased inflation of the ventilated lung that raises the equilibrium end-expiratory pressure beyond the inflection point, oxygenation is likely to deteriorate.</description><identifier>ISSN: 0003-3022</identifier><identifier>EISSN: 1528-1175</identifier><identifier>DOI: 10.1097/00000542-200111000-00012</identifier><identifier>PMID: 11684977</identifier><identifier>CODEN: ANESAV</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott</publisher><subject>Adult ; Aged ; Anesthesia ; Anesthesia depending on type of surgery ; Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Biological and medical sciences ; Female ; Forced Expiratory Volume ; Humans ; Intraoperative Care - methods ; Lung Compliance ; Male ; Maximal Expiratory Flow Rate ; Medical sciences ; Middle Aged ; Positive-Pressure Respiration ; Respiration ; Thoracic and cardiovascular surgery. Cardiopulmonary bypass ; Thoracic Diseases - surgery</subject><ispartof>Anesthesiology (Philadelphia), 2001-11, Vol.95 (5), p.1096-1102</ispartof><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c323t-c87626ff8bbf4396373efcded755b41028a5df228e1d149e5648a9f4323d2eed3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=14082904$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11684977$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>SLINGER, Peter D</creatorcontrib><creatorcontrib>KRUGER, Marelise</creatorcontrib><creatorcontrib>MCRAE, Karen</creatorcontrib><creatorcontrib>WINTON, Timothy</creatorcontrib><title>Relation of the static compliance curve and Positive end-expiratory pressure to oxygenation during one-lung ventilation</title><title>Anesthesiology (Philadelphia)</title><addtitle>Anesthesiology</addtitle><description>Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (PaO(2)) to decrease further. The current study examined whether the effects of PEEP on oxygenation depend on the static compliance curve of the lung to which it is applied. Forty-two adults undergoing thoracic surgery were studied during stable, open-chest, one-lung ventilation. Arterial blood gases were measured during two-lung ventilation and one-lung ventilation before, during, and after the application of 5 cm H(2)O PEEP to the ventilated lung. The plateau end-expiratory pressure and static compliance curve of the ventilated lung were measured with and without applied PEEP, and the lower inflection point was determined from the compliance curve. Mean (+/- SD) PaO(2) values, with a fraction of inspired oxygen of 1.0, were not different during one-lung ventilation before (192 +/- 91 mmHg), during (190 +/- 90), or after ( 205 +/- 79) the addition of 5 cm H(2)O PEEP. The mean plateau end-expiratory pressure increased from 4.2 to 6.8 cm H(2)O with the application of 5 cm H(2)O PEEP and decreased to 4.5 cm H(2)O when 5 cm H(2)O PEEP was removed. Six patients showed a clinically useful (&gt; 20%) increase in PaO(2) with 5 cm H(2)O PEEP, and nine patients had a greater than 20% decrease in PaO(2). The change in PaO(2) with the application of 5 cm H(2)O PEEP correlated in an inverse fashion with the change in the gradient between the end-expiratory pressure and the pressure at the lower inflection point (r = 0.76). The subgroup of patients with a PaO(2) during two-lung ventilation that was less than the mean (365 mmHg) and an end-expiratory pressure during one-lung ventilation without applied PEEP less than the mean were more likely to have an increase in PaO(2) when 5 cm H(2)O PEEP was applied. The effects of the application of external 5 cm H(2)O PEEP on oxygenation during one-lung ventilation correspond to individual changes in the relation between the plateau end-expiratory pressure and the inflection point of the static compliance curve. When the application of PEEP causes the end-expiratory pressure to increase from a low level toward the inflection point, oxygenation is likely to improve. Conversely, if the addition of PEEP causes an increased inflation of the ventilated lung that raises the equilibrium end-expiratory pressure beyond the inflection point, oxygenation is likely to deteriorate.</description><subject>Adult</subject><subject>Aged</subject><subject>Anesthesia</subject><subject>Anesthesia depending on type of surgery</subject><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Biological and medical sciences</subject><subject>Female</subject><subject>Forced Expiratory Volume</subject><subject>Humans</subject><subject>Intraoperative Care - methods</subject><subject>Lung Compliance</subject><subject>Male</subject><subject>Maximal Expiratory Flow Rate</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Positive-Pressure Respiration</subject><subject>Respiration</subject><subject>Thoracic and cardiovascular surgery. Cardiopulmonary bypass</subject><subject>Thoracic Diseases - surgery</subject><issn>0003-3022</issn><issn>1528-1175</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNpFkF1PHCEUhompcdfVv9Bw095h-ZgZmMvG1GpiUmP0esLCwdLMwhQYu_vvi-62S0I4L3nOOcmDEGb0itFefqFvp2044ZQyxmog9TJ-gpas5YowJtsPaFn_BBGU8wU6z_lXjbIV6gwtGOtU00u5RH8eYdTFx4Cjw-Un4FxqNNjEzTR6HQxgM6dXwDpY_BCzL74GCJbAdvJJl5h2eEqQ85wAl4jjdvcCYT_SzsmHFxwDkHGuxSuE4vfrLtCp02OGy8O7Qs83356ub8n9j-9311_viRFcFGKU7HjnnFqvXSP6TkgBzliwsm3XDaNc6dY6zhUwy5oe2q5Ruq8oF5YDWLFCn_dzpxR_z5DLsPHZwDjqAHHOg-RcSNbJCqo9aFLMOYEbpuQ3Ou0GRoc36cM_6cN_6cO79Nr68bBjXm_AHhsPlivw6QDobPToUvXq85FrqOI9bcRfkPSMUQ</recordid><startdate>20011101</startdate><enddate>20011101</enddate><creator>SLINGER, Peter D</creator><creator>KRUGER, Marelise</creator><creator>MCRAE, Karen</creator><creator>WINTON, Timothy</creator><general>Lippincott</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20011101</creationdate><title>Relation of the static compliance curve and Positive end-expiratory pressure to oxygenation during one-lung ventilation</title><author>SLINGER, Peter D ; KRUGER, Marelise ; MCRAE, Karen ; WINTON, Timothy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c323t-c87626ff8bbf4396373efcded755b41028a5df228e1d149e5648a9f4323d2eed3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Anesthesia</topic><topic>Anesthesia depending on type of surgery</topic><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Biological and medical sciences</topic><topic>Female</topic><topic>Forced Expiratory Volume</topic><topic>Humans</topic><topic>Intraoperative Care - methods</topic><topic>Lung Compliance</topic><topic>Male</topic><topic>Maximal Expiratory Flow Rate</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Positive-Pressure Respiration</topic><topic>Respiration</topic><topic>Thoracic and cardiovascular surgery. Cardiopulmonary bypass</topic><topic>Thoracic Diseases - surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>SLINGER, Peter D</creatorcontrib><creatorcontrib>KRUGER, Marelise</creatorcontrib><creatorcontrib>MCRAE, Karen</creatorcontrib><creatorcontrib>WINTON, Timothy</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Anesthesiology (Philadelphia)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SLINGER, Peter D</au><au>KRUGER, Marelise</au><au>MCRAE, Karen</au><au>WINTON, Timothy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Relation of the static compliance curve and Positive end-expiratory pressure to oxygenation during one-lung ventilation</atitle><jtitle>Anesthesiology (Philadelphia)</jtitle><addtitle>Anesthesiology</addtitle><date>2001-11-01</date><risdate>2001</risdate><volume>95</volume><issue>5</issue><spage>1096</spage><epage>1102</epage><pages>1096-1102</pages><issn>0003-3022</issn><eissn>1528-1175</eissn><coden>ANESAV</coden><abstract>Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (PaO(2)) to decrease further. The current study examined whether the effects of PEEP on oxygenation depend on the static compliance curve of the lung to which it is applied. Forty-two adults undergoing thoracic surgery were studied during stable, open-chest, one-lung ventilation. Arterial blood gases were measured during two-lung ventilation and one-lung ventilation before, during, and after the application of 5 cm H(2)O PEEP to the ventilated lung. The plateau end-expiratory pressure and static compliance curve of the ventilated lung were measured with and without applied PEEP, and the lower inflection point was determined from the compliance curve. Mean (+/- SD) PaO(2) values, with a fraction of inspired oxygen of 1.0, were not different during one-lung ventilation before (192 +/- 91 mmHg), during (190 +/- 90), or after ( 205 +/- 79) the addition of 5 cm H(2)O PEEP. The mean plateau end-expiratory pressure increased from 4.2 to 6.8 cm H(2)O with the application of 5 cm H(2)O PEEP and decreased to 4.5 cm H(2)O when 5 cm H(2)O PEEP was removed. Six patients showed a clinically useful (&gt; 20%) increase in PaO(2) with 5 cm H(2)O PEEP, and nine patients had a greater than 20% decrease in PaO(2). The change in PaO(2) with the application of 5 cm H(2)O PEEP correlated in an inverse fashion with the change in the gradient between the end-expiratory pressure and the pressure at the lower inflection point (r = 0.76). The subgroup of patients with a PaO(2) during two-lung ventilation that was less than the mean (365 mmHg) and an end-expiratory pressure during one-lung ventilation without applied PEEP less than the mean were more likely to have an increase in PaO(2) when 5 cm H(2)O PEEP was applied. The effects of the application of external 5 cm H(2)O PEEP on oxygenation during one-lung ventilation correspond to individual changes in the relation between the plateau end-expiratory pressure and the inflection point of the static compliance curve. When the application of PEEP causes the end-expiratory pressure to increase from a low level toward the inflection point, oxygenation is likely to improve. Conversely, if the addition of PEEP causes an increased inflation of the ventilated lung that raises the equilibrium end-expiratory pressure beyond the inflection point, oxygenation is likely to deteriorate.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott</pub><pmid>11684977</pmid><doi>10.1097/00000542-200111000-00012</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0003-3022
ispartof Anesthesiology (Philadelphia), 2001-11, Vol.95 (5), p.1096-1102
issn 0003-3022
1528-1175
language eng
recordid cdi_proquest_miscellaneous_72237167
source HEAL-Link subscriptions: Lippincott Williams & Wilkins
subjects Adult
Aged
Anesthesia
Anesthesia depending on type of surgery
Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
Biological and medical sciences
Female
Forced Expiratory Volume
Humans
Intraoperative Care - methods
Lung Compliance
Male
Maximal Expiratory Flow Rate
Medical sciences
Middle Aged
Positive-Pressure Respiration
Respiration
Thoracic and cardiovascular surgery. Cardiopulmonary bypass
Thoracic Diseases - surgery
title Relation of the static compliance curve and Positive end-expiratory pressure to oxygenation during one-lung ventilation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T10%3A48%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Relation%20of%20the%20static%20compliance%20curve%20and%20Positive%20end-expiratory%20pressure%20to%20oxygenation%20during%20one-lung%20ventilation&rft.jtitle=Anesthesiology%20(Philadelphia)&rft.au=SLINGER,%20Peter%20D&rft.date=2001-11-01&rft.volume=95&rft.issue=5&rft.spage=1096&rft.epage=1102&rft.pages=1096-1102&rft.issn=0003-3022&rft.eissn=1528-1175&rft.coden=ANESAV&rft_id=info:doi/10.1097/00000542-200111000-00012&rft_dat=%3Cproquest_cross%3E72237167%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c323t-c87626ff8bbf4396373efcded755b41028a5df228e1d149e5648a9f4323d2eed3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=72237167&rft_id=info:pmid/11684977&rfr_iscdi=true