Loading…

Electromyographic analysis of a human powered stepper cycle during seated and standing riding

This study examined the muscular activation patterns produced while riding the Step 'n Go, a tricycle powered by a reciprocating vertical motion and typically used by individuals with cognitive, orthopedic, and neuromuscular conditions. Seven normal, adult subjects were tested at three power le...

Full description

Saved in:
Bibliographic Details
Published in:Journal of electromyography and kinesiology 2001-12, Vol.11 (6), p.413-423
Main Authors: Miller, Mark S, Peach, John P, Keller, Tony S
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c458t-d9d12a5646c68b8232b844331645ed5a035f3cda0f99c8758ebbcdc32230c2d33
cites cdi_FETCH-LOGICAL-c458t-d9d12a5646c68b8232b844331645ed5a035f3cda0f99c8758ebbcdc32230c2d33
container_end_page 423
container_issue 6
container_start_page 413
container_title Journal of electromyography and kinesiology
container_volume 11
creator Miller, Mark S
Peach, John P
Keller, Tony S
description This study examined the muscular activation patterns produced while riding the Step 'n Go, a tricycle powered by a reciprocating vertical motion and typically used by individuals with cognitive, orthopedic, and neuromuscular conditions. Seven normal, adult subjects were tested at three power levels (75, 100, and 125 W) during seated and standing riding. Eight lower extremity muscles were examined with surface electromyography. Results showed that the major power producing muscles for this device were the gluteus maximus, vastis lateralis and medialis, rectus femoris, and tibialis anterior. At the highest power level, peak and mean muscular activation in these muscles were substantially lower (17–38%) while riding standing compared to seated, and seems to reflect the benefit of body weight for power production while standing. At the lowest power level, the peak and mean muscle activation differences between positions were less remarkable, and in some cases the standing values were greater than seated. This suggests that significant muscular effort was required to maintain standing posture and balance when riding at low power levels. Individuals able to perform vastis lateralis and medialis intensive activities, such as the concentric portion of a squat or using a stepping machine (Stair Master), should be able to comfortably ride the Step 'n Go at low power levels.
doi_str_mv 10.1016/S1050-6411(01)00019-0
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72344126</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1050641101000190</els_id><sourcerecordid>18252458</sourcerecordid><originalsourceid>FETCH-LOGICAL-c458t-d9d12a5646c68b8232b844331645ed5a035f3cda0f99c8758ebbcdc32230c2d33</originalsourceid><addsrcrecordid>eNqFkcuKFTEQhoMozjj6CEpWoovWqly60ysZhvECAy7UpYR0Uj0T6ZtJt3Le3rTniMuBkApVX6WK_2fsOcIbBKzffkHQUNUK8RXgawDAtoIH7BxNIyvdID4s73_IGXuS84_CNGDgMTtDbKRptTpn368H8muax8N8m9xyFz13kxsOOWY-99zxu210E1_m35Qo8LzSslDi_uAH4mFLcbrlmdxaam7a6-Xecynu4Sl71Lsh07NTvGDf3l9_vfpY3Xz-8Onq8qbySpu1Cm1A4XStal-bzggpOqOUlFgrTUE7kLqXPjjo29abRhvqOh-8FEKCF0HKC_by-O-S5p8b5dWOMXsaBjfRvGXbCKkUivpeEI3QouxUQH0EfZpzTtTbJcXRpYNFsLsB9q8BdlfXQjm7ARZK34vTgK0bKfzvOilegHdHgIoevyIlm32kyVOIqThhwxzvGfEHbQWVcw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>18252458</pqid></control><display><type>article</type><title>Electromyographic analysis of a human powered stepper cycle during seated and standing riding</title><source>ScienceDirect Freedom Collection</source><creator>Miller, Mark S ; Peach, John P ; Keller, Tony S</creator><creatorcontrib>Miller, Mark S ; Peach, John P ; Keller, Tony S</creatorcontrib><description>This study examined the muscular activation patterns produced while riding the Step 'n Go, a tricycle powered by a reciprocating vertical motion and typically used by individuals with cognitive, orthopedic, and neuromuscular conditions. Seven normal, adult subjects were tested at three power levels (75, 100, and 125 W) during seated and standing riding. Eight lower extremity muscles were examined with surface electromyography. Results showed that the major power producing muscles for this device were the gluteus maximus, vastis lateralis and medialis, rectus femoris, and tibialis anterior. At the highest power level, peak and mean muscular activation in these muscles were substantially lower (17–38%) while riding standing compared to seated, and seems to reflect the benefit of body weight for power production while standing. At the lowest power level, the peak and mean muscle activation differences between positions were less remarkable, and in some cases the standing values were greater than seated. This suggests that significant muscular effort was required to maintain standing posture and balance when riding at low power levels. Individuals able to perform vastis lateralis and medialis intensive activities, such as the concentric portion of a squat or using a stepping machine (Stair Master), should be able to comfortably ride the Step 'n Go at low power levels.</description><identifier>ISSN: 1050-6411</identifier><identifier>EISSN: 1873-5711</identifier><identifier>DOI: 10.1016/S1050-6411(01)00019-0</identifier><identifier>PMID: 11738954</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Adult ; Analysis of Variance ; Bicycling ; Bicycling - physiology ; Electromyography ; Exercise ; Human ; Humans ; Leg - physiology ; Male ; Muscle, Skeletal - physiology ; Muscles ; Posture - physiology</subject><ispartof>Journal of electromyography and kinesiology, 2001-12, Vol.11 (6), p.413-423</ispartof><rights>2001 Elsevier Science Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c458t-d9d12a5646c68b8232b844331645ed5a035f3cda0f99c8758ebbcdc32230c2d33</citedby><cites>FETCH-LOGICAL-c458t-d9d12a5646c68b8232b844331645ed5a035f3cda0f99c8758ebbcdc32230c2d33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11738954$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miller, Mark S</creatorcontrib><creatorcontrib>Peach, John P</creatorcontrib><creatorcontrib>Keller, Tony S</creatorcontrib><title>Electromyographic analysis of a human powered stepper cycle during seated and standing riding</title><title>Journal of electromyography and kinesiology</title><addtitle>J Electromyogr Kinesiol</addtitle><description>This study examined the muscular activation patterns produced while riding the Step 'n Go, a tricycle powered by a reciprocating vertical motion and typically used by individuals with cognitive, orthopedic, and neuromuscular conditions. Seven normal, adult subjects were tested at three power levels (75, 100, and 125 W) during seated and standing riding. Eight lower extremity muscles were examined with surface electromyography. Results showed that the major power producing muscles for this device were the gluteus maximus, vastis lateralis and medialis, rectus femoris, and tibialis anterior. At the highest power level, peak and mean muscular activation in these muscles were substantially lower (17–38%) while riding standing compared to seated, and seems to reflect the benefit of body weight for power production while standing. At the lowest power level, the peak and mean muscle activation differences between positions were less remarkable, and in some cases the standing values were greater than seated. This suggests that significant muscular effort was required to maintain standing posture and balance when riding at low power levels. Individuals able to perform vastis lateralis and medialis intensive activities, such as the concentric portion of a squat or using a stepping machine (Stair Master), should be able to comfortably ride the Step 'n Go at low power levels.</description><subject>Adult</subject><subject>Analysis of Variance</subject><subject>Bicycling</subject><subject>Bicycling - physiology</subject><subject>Electromyography</subject><subject>Exercise</subject><subject>Human</subject><subject>Humans</subject><subject>Leg - physiology</subject><subject>Male</subject><subject>Muscle, Skeletal - physiology</subject><subject>Muscles</subject><subject>Posture - physiology</subject><issn>1050-6411</issn><issn>1873-5711</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNqFkcuKFTEQhoMozjj6CEpWoovWqly60ysZhvECAy7UpYR0Uj0T6ZtJt3Le3rTniMuBkApVX6WK_2fsOcIbBKzffkHQUNUK8RXgawDAtoIH7BxNIyvdID4s73_IGXuS84_CNGDgMTtDbKRptTpn368H8muax8N8m9xyFz13kxsOOWY-99zxu210E1_m35Qo8LzSslDi_uAH4mFLcbrlmdxaam7a6-Xecynu4Sl71Lsh07NTvGDf3l9_vfpY3Xz-8Onq8qbySpu1Cm1A4XStal-bzggpOqOUlFgrTUE7kLqXPjjo29abRhvqOh-8FEKCF0HKC_by-O-S5p8b5dWOMXsaBjfRvGXbCKkUivpeEI3QouxUQH0EfZpzTtTbJcXRpYNFsLsB9q8BdlfXQjm7ARZK34vTgK0bKfzvOilegHdHgIoevyIlm32kyVOIqThhwxzvGfEHbQWVcw</recordid><startdate>20011201</startdate><enddate>20011201</enddate><creator>Miller, Mark S</creator><creator>Peach, John P</creator><creator>Keller, Tony S</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TS</scope><scope>7X8</scope></search><sort><creationdate>20011201</creationdate><title>Electromyographic analysis of a human powered stepper cycle during seated and standing riding</title><author>Miller, Mark S ; Peach, John P ; Keller, Tony S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c458t-d9d12a5646c68b8232b844331645ed5a035f3cda0f99c8758ebbcdc32230c2d33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Adult</topic><topic>Analysis of Variance</topic><topic>Bicycling</topic><topic>Bicycling - physiology</topic><topic>Electromyography</topic><topic>Exercise</topic><topic>Human</topic><topic>Humans</topic><topic>Leg - physiology</topic><topic>Male</topic><topic>Muscle, Skeletal - physiology</topic><topic>Muscles</topic><topic>Posture - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miller, Mark S</creatorcontrib><creatorcontrib>Peach, John P</creatorcontrib><creatorcontrib>Keller, Tony S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Physical Education Index</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of electromyography and kinesiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miller, Mark S</au><au>Peach, John P</au><au>Keller, Tony S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electromyographic analysis of a human powered stepper cycle during seated and standing riding</atitle><jtitle>Journal of electromyography and kinesiology</jtitle><addtitle>J Electromyogr Kinesiol</addtitle><date>2001-12-01</date><risdate>2001</risdate><volume>11</volume><issue>6</issue><spage>413</spage><epage>423</epage><pages>413-423</pages><issn>1050-6411</issn><eissn>1873-5711</eissn><abstract>This study examined the muscular activation patterns produced while riding the Step 'n Go, a tricycle powered by a reciprocating vertical motion and typically used by individuals with cognitive, orthopedic, and neuromuscular conditions. Seven normal, adult subjects were tested at three power levels (75, 100, and 125 W) during seated and standing riding. Eight lower extremity muscles were examined with surface electromyography. Results showed that the major power producing muscles for this device were the gluteus maximus, vastis lateralis and medialis, rectus femoris, and tibialis anterior. At the highest power level, peak and mean muscular activation in these muscles were substantially lower (17–38%) while riding standing compared to seated, and seems to reflect the benefit of body weight for power production while standing. At the lowest power level, the peak and mean muscle activation differences between positions were less remarkable, and in some cases the standing values were greater than seated. This suggests that significant muscular effort was required to maintain standing posture and balance when riding at low power levels. Individuals able to perform vastis lateralis and medialis intensive activities, such as the concentric portion of a squat or using a stepping machine (Stair Master), should be able to comfortably ride the Step 'n Go at low power levels.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>11738954</pmid><doi>10.1016/S1050-6411(01)00019-0</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1050-6411
ispartof Journal of electromyography and kinesiology, 2001-12, Vol.11 (6), p.413-423
issn 1050-6411
1873-5711
language eng
recordid cdi_proquest_miscellaneous_72344126
source ScienceDirect Freedom Collection
subjects Adult
Analysis of Variance
Bicycling
Bicycling - physiology
Electromyography
Exercise
Human
Humans
Leg - physiology
Male
Muscle, Skeletal - physiology
Muscles
Posture - physiology
title Electromyographic analysis of a human powered stepper cycle during seated and standing riding
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T12%3A29%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electromyographic%20analysis%20of%20a%20human%20powered%20stepper%20cycle%20during%20seated%20and%20standing%20riding&rft.jtitle=Journal%20of%20electromyography%20and%20kinesiology&rft.au=Miller,%20Mark%20S&rft.date=2001-12-01&rft.volume=11&rft.issue=6&rft.spage=413&rft.epage=423&rft.pages=413-423&rft.issn=1050-6411&rft.eissn=1873-5711&rft_id=info:doi/10.1016/S1050-6411(01)00019-0&rft_dat=%3Cproquest_cross%3E18252458%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c458t-d9d12a5646c68b8232b844331645ed5a035f3cda0f99c8758ebbcdc32230c2d33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=18252458&rft_id=info:pmid/11738954&rfr_iscdi=true