Comparison of Preoperative Radiographs and Intraoperative Findings of Fixation of Hemispheric Porous-Coated Sockets

BackgroundThe radiographic criteria for identification of loose cementless acetabular components have not been well established. The purpose of this study was to compare the radiographic appearance of a hemispheric porous-coated cementless cup fixed with screws with the intraoperative findings with...

Full description

Saved in:
Bibliographic Details
Published in:Journal of bone and joint surgery. American volume 2001-12, Vol.83 (12), p.1865-1870
Main Authors: Udomkiat, Pacharapol, Wan, Zhinian, Dorr, Lawrence D
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:BackgroundThe radiographic criteria for identification of loose cementless acetabular components have not been well established. The purpose of this study was to compare the radiographic appearance of a hemispheric porous-coated cementless cup fixed with screws with the intraoperative findings with regard to the fixation status.MethodsThe quality of the cup fixation was evaluated at fifty-two hip revisions that were performed, for reasons other than infection, at an average of 89.9 months (range, 33.8 to 150.1 months) after the primary operations. The fixation status at the revision surgery was compared with the findings on sequential anteroposterior and lateral radiographs of these sockets. Sequential radiographs of an additional 100 total hip replacements that had not required a reoperation and that had been followed for an average of 121 months were also measured.ResultsLoosening of the socket was radiographically identified by (1) radiolucent lines that initially appeared after two years, (2) progression of radiolucent lines after two years, (3) radiolucent lines in all three zones, (4) radiolucent lines 2 mm or wider in any zone, or (5) migration. The sensitivity of these criteria was 94%, and the specificity was 100%. The criteria had a positive predictive value of 100% and a negative predictive value of 97%.ConclusionsThe most predictive radiographic findings for early diagnosis of loosening of a hemispheric porous-coated cup were progression of radiolucent lines more than two years after the operation and any new radiolucent line of 1 mm or wider that appeared more than two years postoperatively. Sequential anteroposterior and lateral radiographs are necessary to assess the time of onset and progression of radiolucent lines in order to identify loose hemispheric porous-coated cups accurately.
ISSN:0021-9355
1535-1386
DOI:10.2106/00004623-200112000-00015