Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem

Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of arthroplasty 2000-10, Vol.15 (7), p.944-946
Main Authors: Staal, H.M., Heyligers, I.C., van der Sluijs, J.A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863
cites cdi_FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863
container_end_page 946
container_issue 7
container_start_page 944
container_title The Journal of arthroplasty
container_volume 15
creator Staal, H.M.
Heyligers, I.C.
van der Sluijs, J.A.
description Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis.
doi_str_mv 10.1054/arth.2000.8095
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72379367</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540300929322</els_id><sourcerecordid>72379367</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863</originalsourceid><addsrcrecordid>eNp1kD1v3DAMhoWgQe7ysXYsNHXzlZIsWx6LoGkLHJChySwoEt1TYVuuJCe4fx8Zd0CnTuTw8CH5EvKRwY6BrL-YmA87DgA7BZ28IFsmBa9UDc0HsgWlRCVrEBtyndIfAMakrK_IhjFoWC3VloRfGUfqfJoHY3HEKVO3RD_9phHdYrMPEw09NSsyBGsyOnriSpNDNgM9-JmuZ8RQHCkf6ZvPhzIxh8Gnw4qZGYuNprLqllz2Zkh4d6435Pnh29P9j2r_-P3n_dd9ZUUNuXIcunK8tMhlp7iDvnNMKmNr07rWOcGxB2EZU7L0_MXYRrXCGNUy1XHViBvy-eSdY_i7YMp69MniMJgJw5J0y0XbiaYt4O4E2hhSitjrOfrRxKNmoNeI9fqbXiPWa8Rl4NPZvLyM6P7h50wLoE4Alv9ePUadrMfJovMRbdYu-P-53wEZSoxJ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72379367</pqid></control><display><type>article</type><title>Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem</title><source>ScienceDirect Journals</source><creator>Staal, H.M. ; Heyligers, I.C. ; van der Sluijs, J.A.</creator><creatorcontrib>Staal, H.M. ; Heyligers, I.C. ; van der Sluijs, J.A.</creatorcontrib><description>Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1054/arth.2000.8095</identifier><identifier>PMID: 11061458</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Aged ; Arthroplasty, Replacement, Hip ; Hip Prosthesis ; Humans ; luxation ; Male ; Prosthesis Failure ; reposition ; stem dislodgment ; Surface Properties ; total hip arthroplasty</subject><ispartof>The Journal of arthroplasty, 2000-10, Vol.15 (7), p.944-946</ispartof><rights>2000 Churchill Livingstone</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863</citedby><cites>FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11061458$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Staal, H.M.</creatorcontrib><creatorcontrib>Heyligers, I.C.</creatorcontrib><creatorcontrib>van der Sluijs, J.A.</creatorcontrib><title>Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis.</description><subject>Aged</subject><subject>Arthroplasty, Replacement, Hip</subject><subject>Hip Prosthesis</subject><subject>Humans</subject><subject>luxation</subject><subject>Male</subject><subject>Prosthesis Failure</subject><subject>reposition</subject><subject>stem dislodgment</subject><subject>Surface Properties</subject><subject>total hip arthroplasty</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNp1kD1v3DAMhoWgQe7ysXYsNHXzlZIsWx6LoGkLHJChySwoEt1TYVuuJCe4fx8Zd0CnTuTw8CH5EvKRwY6BrL-YmA87DgA7BZ28IFsmBa9UDc0HsgWlRCVrEBtyndIfAMakrK_IhjFoWC3VloRfGUfqfJoHY3HEKVO3RD_9phHdYrMPEw09NSsyBGsyOnriSpNDNgM9-JmuZ8RQHCkf6ZvPhzIxh8Gnw4qZGYuNprLqllz2Zkh4d6435Pnh29P9j2r_-P3n_dd9ZUUNuXIcunK8tMhlp7iDvnNMKmNr07rWOcGxB2EZU7L0_MXYRrXCGNUy1XHViBvy-eSdY_i7YMp69MniMJgJw5J0y0XbiaYt4O4E2hhSitjrOfrRxKNmoNeI9fqbXiPWa8Rl4NPZvLyM6P7h50wLoE4Alv9ePUadrMfJovMRbdYu-P-53wEZSoxJ</recordid><startdate>20001001</startdate><enddate>20001001</enddate><creator>Staal, H.M.</creator><creator>Heyligers, I.C.</creator><creator>van der Sluijs, J.A.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20001001</creationdate><title>Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem</title><author>Staal, H.M. ; Heyligers, I.C. ; van der Sluijs, J.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Aged</topic><topic>Arthroplasty, Replacement, Hip</topic><topic>Hip Prosthesis</topic><topic>Humans</topic><topic>luxation</topic><topic>Male</topic><topic>Prosthesis Failure</topic><topic>reposition</topic><topic>stem dislodgment</topic><topic>Surface Properties</topic><topic>total hip arthroplasty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Staal, H.M.</creatorcontrib><creatorcontrib>Heyligers, I.C.</creatorcontrib><creatorcontrib>van der Sluijs, J.A.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Staal, H.M.</au><au>Heyligers, I.C.</au><au>van der Sluijs, J.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>2000-10-01</date><risdate>2000</risdate><volume>15</volume><issue>7</issue><spage>944</spage><epage>946</epage><pages>944-946</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>11061458</pmid><doi>10.1054/arth.2000.8095</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0883-5403
ispartof The Journal of arthroplasty, 2000-10, Vol.15 (7), p.944-946
issn 0883-5403
1532-8406
language eng
recordid cdi_proquest_miscellaneous_72379367
source ScienceDirect Journals
subjects Aged
Arthroplasty, Replacement, Hip
Hip Prosthesis
Humans
luxation
Male
Prosthesis Failure
reposition
stem dislodgment
Surface Properties
total hip arthroplasty
title Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T16%3A56%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stem%20displacement%20during%20reduction%20of%20a%20dislocated%20cemented%20total%20hip%20arthroplasty%20with%20a%20polished%20tapered%20stem&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Staal,%20H.M.&rft.date=2000-10-01&rft.volume=15&rft.issue=7&rft.spage=944&rft.epage=946&rft.pages=944-946&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1054/arth.2000.8095&rft_dat=%3Cproquest_cross%3E72379367%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=72379367&rft_id=info:pmid/11061458&rfr_iscdi=true