Loading…
Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem
Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the...
Saved in:
Published in: | The Journal of arthroplasty 2000-10, Vol.15 (7), p.944-946 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863 |
---|---|
cites | cdi_FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863 |
container_end_page | 946 |
container_issue | 7 |
container_start_page | 944 |
container_title | The Journal of arthroplasty |
container_volume | 15 |
creator | Staal, H.M. Heyligers, I.C. van der Sluijs, J.A. |
description | Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis. |
doi_str_mv | 10.1054/arth.2000.8095 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72379367</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540300929322</els_id><sourcerecordid>72379367</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863</originalsourceid><addsrcrecordid>eNp1kD1v3DAMhoWgQe7ysXYsNHXzlZIsWx6LoGkLHJChySwoEt1TYVuuJCe4fx8Zd0CnTuTw8CH5EvKRwY6BrL-YmA87DgA7BZ28IFsmBa9UDc0HsgWlRCVrEBtyndIfAMakrK_IhjFoWC3VloRfGUfqfJoHY3HEKVO3RD_9phHdYrMPEw09NSsyBGsyOnriSpNDNgM9-JmuZ8RQHCkf6ZvPhzIxh8Gnw4qZGYuNprLqllz2Zkh4d6435Pnh29P9j2r_-P3n_dd9ZUUNuXIcunK8tMhlp7iDvnNMKmNr07rWOcGxB2EZU7L0_MXYRrXCGNUy1XHViBvy-eSdY_i7YMp69MniMJgJw5J0y0XbiaYt4O4E2hhSitjrOfrRxKNmoNeI9fqbXiPWa8Rl4NPZvLyM6P7h50wLoE4Alv9ePUadrMfJovMRbdYu-P-53wEZSoxJ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72379367</pqid></control><display><type>article</type><title>Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem</title><source>ScienceDirect Journals</source><creator>Staal, H.M. ; Heyligers, I.C. ; van der Sluijs, J.A.</creator><creatorcontrib>Staal, H.M. ; Heyligers, I.C. ; van der Sluijs, J.A.</creatorcontrib><description>Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1054/arth.2000.8095</identifier><identifier>PMID: 11061458</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Aged ; Arthroplasty, Replacement, Hip ; Hip Prosthesis ; Humans ; luxation ; Male ; Prosthesis Failure ; reposition ; stem dislodgment ; Surface Properties ; total hip arthroplasty</subject><ispartof>The Journal of arthroplasty, 2000-10, Vol.15 (7), p.944-946</ispartof><rights>2000 Churchill Livingstone</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863</citedby><cites>FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11061458$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Staal, H.M.</creatorcontrib><creatorcontrib>Heyligers, I.C.</creatorcontrib><creatorcontrib>van der Sluijs, J.A.</creatorcontrib><title>Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis.</description><subject>Aged</subject><subject>Arthroplasty, Replacement, Hip</subject><subject>Hip Prosthesis</subject><subject>Humans</subject><subject>luxation</subject><subject>Male</subject><subject>Prosthesis Failure</subject><subject>reposition</subject><subject>stem dislodgment</subject><subject>Surface Properties</subject><subject>total hip arthroplasty</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNp1kD1v3DAMhoWgQe7ysXYsNHXzlZIsWx6LoGkLHJChySwoEt1TYVuuJCe4fx8Zd0CnTuTw8CH5EvKRwY6BrL-YmA87DgA7BZ28IFsmBa9UDc0HsgWlRCVrEBtyndIfAMakrK_IhjFoWC3VloRfGUfqfJoHY3HEKVO3RD_9phHdYrMPEw09NSsyBGsyOnriSpNDNgM9-JmuZ8RQHCkf6ZvPhzIxh8Gnw4qZGYuNprLqllz2Zkh4d6435Pnh29P9j2r_-P3n_dd9ZUUNuXIcunK8tMhlp7iDvnNMKmNr07rWOcGxB2EZU7L0_MXYRrXCGNUy1XHViBvy-eSdY_i7YMp69MniMJgJw5J0y0XbiaYt4O4E2hhSitjrOfrRxKNmoNeI9fqbXiPWa8Rl4NPZvLyM6P7h50wLoE4Alv9ePUadrMfJovMRbdYu-P-53wEZSoxJ</recordid><startdate>20001001</startdate><enddate>20001001</enddate><creator>Staal, H.M.</creator><creator>Heyligers, I.C.</creator><creator>van der Sluijs, J.A.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20001001</creationdate><title>Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem</title><author>Staal, H.M. ; Heyligers, I.C. ; van der Sluijs, J.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Aged</topic><topic>Arthroplasty, Replacement, Hip</topic><topic>Hip Prosthesis</topic><topic>Humans</topic><topic>luxation</topic><topic>Male</topic><topic>Prosthesis Failure</topic><topic>reposition</topic><topic>stem dislodgment</topic><topic>Surface Properties</topic><topic>total hip arthroplasty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Staal, H.M.</creatorcontrib><creatorcontrib>Heyligers, I.C.</creatorcontrib><creatorcontrib>van der Sluijs, J.A.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Staal, H.M.</au><au>Heyligers, I.C.</au><au>van der Sluijs, J.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>2000-10-01</date><risdate>2000</risdate><volume>15</volume><issue>7</issue><spage>944</spage><epage>946</epage><pages>944-946</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>Displacement of the polished stem of a total hip arthroplasty from its cemented mantle occurred as a complication of an attempted closed reduction after luxation. No cement fractures were seen during subsequent reoperation. The complication can be avoided if cement is placed over the shoulder of the prosthesis.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>11061458</pmid><doi>10.1054/arth.2000.8095</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0883-5403 |
ispartof | The Journal of arthroplasty, 2000-10, Vol.15 (7), p.944-946 |
issn | 0883-5403 1532-8406 |
language | eng |
recordid | cdi_proquest_miscellaneous_72379367 |
source | ScienceDirect Journals |
subjects | Aged Arthroplasty, Replacement, Hip Hip Prosthesis Humans luxation Male Prosthesis Failure reposition stem dislodgment Surface Properties total hip arthroplasty |
title | Stem displacement during reduction of a dislocated cemented total hip arthroplasty with a polished tapered stem |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T16%3A56%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stem%20displacement%20during%20reduction%20of%20a%20dislocated%20cemented%20total%20hip%20arthroplasty%20with%20a%20polished%20tapered%20stem&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Staal,%20H.M.&rft.date=2000-10-01&rft.volume=15&rft.issue=7&rft.spage=944&rft.epage=946&rft.pages=944-946&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1054/arth.2000.8095&rft_dat=%3Cproquest_cross%3E72379367%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c340t-d2098835ce25982d0f9d158ac4a7d7dd32ef03c1185d322bac6873aa871892863%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=72379367&rft_id=info:pmid/11061458&rfr_iscdi=true |