Loading…
Four dimensional bolus tagging imaging of pulsatile flow
Inversion bolus tagging MR methods were used to provide a graphic depiction of the axial velocity in three spatial dimensions for pulsatile flow through complex geometries. Visualization of the flow field was readily apparent, and a train of tagged boli were depicted providing an immediate overview...
Saved in:
Published in: | Magnetic resonance imaging 2000-11, Vol.18 (9), p.1097-1107 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c389t-4d526cd269b70e2005f521b3bc48b33e04b2b2b9af1ef4dd2896ee764554571f3 |
---|---|
cites | cdi_FETCH-LOGICAL-c389t-4d526cd269b70e2005f521b3bc48b33e04b2b2b9af1ef4dd2896ee764554571f3 |
container_end_page | 1107 |
container_issue | 9 |
container_start_page | 1097 |
container_title | Magnetic resonance imaging |
container_volume | 18 |
creator | Franck, Anders Jou, Liang-Der van Tyen, Rem Saloner, David |
description | Inversion bolus tagging MR methods were used to provide a graphic depiction of the axial velocity in three spatial dimensions for pulsatile flow through complex geometries. Visualization of the flow field was readily apparent, and a train of tagged boli were depicted providing an immediate overview of the displacement of flowing fluid over the entire pulsatile cycle. Tagging efficiency obtained using adiabatic inversion pulses was improved compared to that with a windowed sinc pulse. Results from phantom experiments on steady flow were correlated with computational fluid dynamic (CFD) simulations. The use of 3D methods reduced spatial partial volume effects, and the displacement of boli in a steady flow experiment correlated well with CFD simulations. The use of adiabatic inversion pulses resulted in sharp edged inversion regions with good retention of longitudinal magnetization. However in order to keep the pulse duration short, of the order of 2–5 ms, a rather large RF amplitude had to be used. The inversion bolus tagging method is useful in visualizing the flow field in multiple levels for pulsatile fluid flowing through complex geometries, and may be useful in fluid dynamic applications. |
doi_str_mv | 10.1016/S0730-725X(00)00204-6 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72477253</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0730725X00002046</els_id><sourcerecordid>72477253</sourcerecordid><originalsourceid>FETCH-LOGICAL-c389t-4d526cd269b70e2005f521b3bc48b33e04b2b2b9af1ef4dd2896ee764554571f3</originalsourceid><addsrcrecordid>eNqFkF1LHTEQhoNU6tH2JygLBWkv1k6-NrtXIlKtIHihhd6FbHZyiORsTpPdiv_enA_sZScXc_PMzJuHkFMKFxRo8_0RFIdaMfn7K8A3AAaibg7IgraK17LtxAeyeEeOyHHOzwAgGZcfyREt1apGLEh7E-dUDX6FY_ZxNKHqY5hzNZnl0o_Lyq_MtkdXreeQzeQDVi7El0_k0JmQ8fO-n5BfNz-ern_W9w-3d9dX97XlbTfVYpCssQNrul4BspLASUZ73lvR9pwjiJ6V1xlH0YlhYG3XIJZoUgqpqOMn5Hy3d53inxnzpFc-WwzBjBjnrBUTqnyRF1DuQJtizgmdXqeSPr1qCnqjTG-V6Y0PDaC3ynRT5s72B-Z-hcO_qb2jAnzZAyZbE1wyo_X5nWuFArlZc7mjsMj46zHpbD2OFgef0E56iP4_Qd4AG4SHGw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72477253</pqid></control><display><type>article</type><title>Four dimensional bolus tagging imaging of pulsatile flow</title><source>Elsevier</source><creator>Franck, Anders ; Jou, Liang-Der ; van Tyen, Rem ; Saloner, David</creator><creatorcontrib>Franck, Anders ; Jou, Liang-Der ; van Tyen, Rem ; Saloner, David</creatorcontrib><description>Inversion bolus tagging MR methods were used to provide a graphic depiction of the axial velocity in three spatial dimensions for pulsatile flow through complex geometries. Visualization of the flow field was readily apparent, and a train of tagged boli were depicted providing an immediate overview of the displacement of flowing fluid over the entire pulsatile cycle. Tagging efficiency obtained using adiabatic inversion pulses was improved compared to that with a windowed sinc pulse. Results from phantom experiments on steady flow were correlated with computational fluid dynamic (CFD) simulations. The use of 3D methods reduced spatial partial volume effects, and the displacement of boli in a steady flow experiment correlated well with CFD simulations. The use of adiabatic inversion pulses resulted in sharp edged inversion regions with good retention of longitudinal magnetization. However in order to keep the pulse duration short, of the order of 2–5 ms, a rather large RF amplitude had to be used. The inversion bolus tagging method is useful in visualizing the flow field in multiple levels for pulsatile fluid flowing through complex geometries, and may be useful in fluid dynamic applications.</description><identifier>ISSN: 0730-725X</identifier><identifier>EISSN: 1873-5894</identifier><identifier>DOI: 10.1016/S0730-725X(00)00204-6</identifier><identifier>PMID: 11118764</identifier><identifier>CODEN: MRIMDQ</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Biological and medical sciences ; Blood Flow Velocity ; Cardiovascular system ; Computer Simulation ; Humans ; Imaging, Three-Dimensional ; Investigative techniques, diagnostic techniques (general aspects) ; Magnetic Resonance Imaging - methods ; Medical sciences ; Phantoms, Imaging ; Pulsatile Flow ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Rheology</subject><ispartof>Magnetic resonance imaging, 2000-11, Vol.18 (9), p.1097-1107</ispartof><rights>2000 Elsevier Science Inc.</rights><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c389t-4d526cd269b70e2005f521b3bc48b33e04b2b2b9af1ef4dd2896ee764554571f3</citedby><cites>FETCH-LOGICAL-c389t-4d526cd269b70e2005f521b3bc48b33e04b2b2b9af1ef4dd2896ee764554571f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=847056$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11118764$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Franck, Anders</creatorcontrib><creatorcontrib>Jou, Liang-Der</creatorcontrib><creatorcontrib>van Tyen, Rem</creatorcontrib><creatorcontrib>Saloner, David</creatorcontrib><title>Four dimensional bolus tagging imaging of pulsatile flow</title><title>Magnetic resonance imaging</title><addtitle>Magn Reson Imaging</addtitle><description>Inversion bolus tagging MR methods were used to provide a graphic depiction of the axial velocity in three spatial dimensions for pulsatile flow through complex geometries. Visualization of the flow field was readily apparent, and a train of tagged boli were depicted providing an immediate overview of the displacement of flowing fluid over the entire pulsatile cycle. Tagging efficiency obtained using adiabatic inversion pulses was improved compared to that with a windowed sinc pulse. Results from phantom experiments on steady flow were correlated with computational fluid dynamic (CFD) simulations. The use of 3D methods reduced spatial partial volume effects, and the displacement of boli in a steady flow experiment correlated well with CFD simulations. The use of adiabatic inversion pulses resulted in sharp edged inversion regions with good retention of longitudinal magnetization. However in order to keep the pulse duration short, of the order of 2–5 ms, a rather large RF amplitude had to be used. The inversion bolus tagging method is useful in visualizing the flow field in multiple levels for pulsatile fluid flowing through complex geometries, and may be useful in fluid dynamic applications.</description><subject>Biological and medical sciences</subject><subject>Blood Flow Velocity</subject><subject>Cardiovascular system</subject><subject>Computer Simulation</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Medical sciences</subject><subject>Phantoms, Imaging</subject><subject>Pulsatile Flow</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Rheology</subject><issn>0730-725X</issn><issn>1873-5894</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNqFkF1LHTEQhoNU6tH2JygLBWkv1k6-NrtXIlKtIHihhd6FbHZyiORsTpPdiv_enA_sZScXc_PMzJuHkFMKFxRo8_0RFIdaMfn7K8A3AAaibg7IgraK17LtxAeyeEeOyHHOzwAgGZcfyREt1apGLEh7E-dUDX6FY_ZxNKHqY5hzNZnl0o_Lyq_MtkdXreeQzeQDVi7El0_k0JmQ8fO-n5BfNz-ern_W9w-3d9dX97XlbTfVYpCssQNrul4BspLASUZ73lvR9pwjiJ6V1xlH0YlhYG3XIJZoUgqpqOMn5Hy3d53inxnzpFc-WwzBjBjnrBUTqnyRF1DuQJtizgmdXqeSPr1qCnqjTG-V6Y0PDaC3ynRT5s72B-Z-hcO_qb2jAnzZAyZbE1wyo_X5nWuFArlZc7mjsMj46zHpbD2OFgef0E56iP4_Qd4AG4SHGw</recordid><startdate>20001101</startdate><enddate>20001101</enddate><creator>Franck, Anders</creator><creator>Jou, Liang-Der</creator><creator>van Tyen, Rem</creator><creator>Saloner, David</creator><general>Elsevier Inc</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20001101</creationdate><title>Four dimensional bolus tagging imaging of pulsatile flow</title><author>Franck, Anders ; Jou, Liang-Der ; van Tyen, Rem ; Saloner, David</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c389t-4d526cd269b70e2005f521b3bc48b33e04b2b2b9af1ef4dd2896ee764554571f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Biological and medical sciences</topic><topic>Blood Flow Velocity</topic><topic>Cardiovascular system</topic><topic>Computer Simulation</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Medical sciences</topic><topic>Phantoms, Imaging</topic><topic>Pulsatile Flow</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Rheology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Franck, Anders</creatorcontrib><creatorcontrib>Jou, Liang-Der</creatorcontrib><creatorcontrib>van Tyen, Rem</creatorcontrib><creatorcontrib>Saloner, David</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Magnetic resonance imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Franck, Anders</au><au>Jou, Liang-Der</au><au>van Tyen, Rem</au><au>Saloner, David</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Four dimensional bolus tagging imaging of pulsatile flow</atitle><jtitle>Magnetic resonance imaging</jtitle><addtitle>Magn Reson Imaging</addtitle><date>2000-11-01</date><risdate>2000</risdate><volume>18</volume><issue>9</issue><spage>1097</spage><epage>1107</epage><pages>1097-1107</pages><issn>0730-725X</issn><eissn>1873-5894</eissn><coden>MRIMDQ</coden><abstract>Inversion bolus tagging MR methods were used to provide a graphic depiction of the axial velocity in three spatial dimensions for pulsatile flow through complex geometries. Visualization of the flow field was readily apparent, and a train of tagged boli were depicted providing an immediate overview of the displacement of flowing fluid over the entire pulsatile cycle. Tagging efficiency obtained using adiabatic inversion pulses was improved compared to that with a windowed sinc pulse. Results from phantom experiments on steady flow were correlated with computational fluid dynamic (CFD) simulations. The use of 3D methods reduced spatial partial volume effects, and the displacement of boli in a steady flow experiment correlated well with CFD simulations. The use of adiabatic inversion pulses resulted in sharp edged inversion regions with good retention of longitudinal magnetization. However in order to keep the pulse duration short, of the order of 2–5 ms, a rather large RF amplitude had to be used. The inversion bolus tagging method is useful in visualizing the flow field in multiple levels for pulsatile fluid flowing through complex geometries, and may be useful in fluid dynamic applications.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>11118764</pmid><doi>10.1016/S0730-725X(00)00204-6</doi><tpages>11</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0730-725X |
ispartof | Magnetic resonance imaging, 2000-11, Vol.18 (9), p.1097-1107 |
issn | 0730-725X 1873-5894 |
language | eng |
recordid | cdi_proquest_miscellaneous_72477253 |
source | Elsevier |
subjects | Biological and medical sciences Blood Flow Velocity Cardiovascular system Computer Simulation Humans Imaging, Three-Dimensional Investigative techniques, diagnostic techniques (general aspects) Magnetic Resonance Imaging - methods Medical sciences Phantoms, Imaging Pulsatile Flow Radiodiagnosis. Nmr imagery. Nmr spectrometry Rheology |
title | Four dimensional bolus tagging imaging of pulsatile flow |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T17%3A35%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Four%20dimensional%20bolus%20tagging%20imaging%20of%20pulsatile%20flow&rft.jtitle=Magnetic%20resonance%20imaging&rft.au=Franck,%20Anders&rft.date=2000-11-01&rft.volume=18&rft.issue=9&rft.spage=1097&rft.epage=1107&rft.pages=1097-1107&rft.issn=0730-725X&rft.eissn=1873-5894&rft.coden=MRIMDQ&rft_id=info:doi/10.1016/S0730-725X(00)00204-6&rft_dat=%3Cproquest_cross%3E72477253%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c389t-4d526cd269b70e2005f521b3bc48b33e04b2b2b9af1ef4dd2896ee764554571f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=72477253&rft_id=info:pmid/11118764&rfr_iscdi=true |