Fourier Analysis in Patients with Different Pacing Modes
The purpose of this study was to evaluate the usefulness of phase analysis in detecting the altered activation sequence induced by different pacing modes. Radionulide ventriculography and planar gated blood pool scintigraphy were performed at rest in 56 patients with different pacemakers. This metho...
Saved in:
Published in: | Pacing and clinical electrophysiology 1991-09, Vol.14 (9), p.1351-1358 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c4381-84b799305bffef1391844f4956b4310d6f2a5ded2e1fbcc7a903a253a5b1f08c3 |
---|---|
cites | cdi_FETCH-LOGICAL-c4381-84b799305bffef1391844f4956b4310d6f2a5ded2e1fbcc7a903a253a5b1f08c3 |
container_end_page | 1358 |
container_issue | 9 |
container_start_page | 1351 |
container_title | Pacing and clinical electrophysiology |
container_volume | 14 |
creator | SANTOMAURO, MAURIZIO FAZIO, SERAFINO FERRARO, SERGIO MADDALENA, GIOVANNI PAPACCIOLI, GIUSEPPE PAPPONE, CARLO BETOCCHI, SANDRO CHIARIELLO, MASSIMO |
description | The purpose of this study was to evaluate the usefulness of phase analysis in detecting the altered activation sequence induced by different pacing modes. Radionulide ventriculography and planar gated blood pool scintigraphy were performed at rest in 56 patients with different pacemakers. This method permitted us to localize the pacemaker impulse site in the right ventricie and its diffusion in the heart. In patients with VVI pacemaker, this technique showed an evident asynchronism of contraction and relaxation of each ventricle and the standard deviation of phase angle (σ), calculated by computer, is greater during pacing than sinus rhythm for left (LV) and right (RV) ventricles (LV σ: 17°± 4 vs 11°± 3, < 0.001; RV σ: 31°± 7 vs 14°± 4, P < 0.001). In the patients with VVI rate responsive pacemakers, the LV σ changed from 18.5 ± 3 under pacing to 11°± 3 in sinus rhythm, P < 0.001, while the RV σ changed from 30°± 8 to 14°± 4, P < 0.001. Instead in the patients with DDD pacemakers, the LV σ changed from 15.5°± 2 under pacing to 11°± 3 in sinus rhythm, P < 0.05, while the RV cr changed from 29.1°± 6 to 14°± 4, P < 0.001. Besides in patients with VDD pacemakers, the LV σ changed from 14.9°± 3 during pacing to 11°± 3 in sinus rhythm, P < 0.01, and from 27.5°± 5 to 14°± 4 for the right ventricle, P < 0.01. So the technique of Fourier analysis permits us to examine the effects of a temporal inhomogeneity induced by different pacing modes, and it can be utilized to assess the optimal atrioventricular delay in DDD paced patients. |
doi_str_mv | 10.1111/j.1540-8159.1991.tb02880.x |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72494677</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72494677</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4381-84b799305bffef1391844f4956b4310d6f2a5ded2e1fbcc7a903a253a5b1f08c3</originalsourceid><addsrcrecordid>eNqVkMtOwzAQRS0EgvL4BKSIBbsET2zHNivaAgXEa8FjaTmJDS5pAnYq2r8nVSpYMxtrfGfOSAehI8AJdHUyTYBRHAtgMgEpIWlznAqBk8UGGvxGm2iAgfJYECF30G4IU4xxhinbRtvAU8xSMUDispl7Z3w0rHW1DC5Ero4edetM3Ybo27Xv0bmz1viu7_4LV79Fd01pwj7asroK5mD97qHny4un8VV8-zC5Hg9v44ISAbGgOZeSYJZ3EAtEgqDUUsmynBLAZWZTzUpTpgZsXhRcS0x0yohmOVgsCrKHjnvup2--5ia0auZCYapK16aZB8VTKmnGeTd42g8WvgnBG6s-vZtpv1SA1UqbmqqVG7Vyo1ba1FqbWnTLh-sr83xmyr_V3lOXn_X5t6vM8h9k9TgcXwBh0CHiHuFCaxa_CO0_VMYJZ-r1fqLGVzc3owl5USPyA8RXi6k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72494677</pqid></control><display><type>article</type><title>Fourier Analysis in Patients with Different Pacing Modes</title><source>SPORTDiscus with Full Text</source><creator>SANTOMAURO, MAURIZIO ; FAZIO, SERAFINO ; FERRARO, SERGIO ; MADDALENA, GIOVANNI ; PAPACCIOLI, GIUSEPPE ; PAPPONE, CARLO ; BETOCCHI, SANDRO ; CHIARIELLO, MASSIMO</creator><creatorcontrib>SANTOMAURO, MAURIZIO ; FAZIO, SERAFINO ; FERRARO, SERGIO ; MADDALENA, GIOVANNI ; PAPACCIOLI, GIUSEPPE ; PAPPONE, CARLO ; BETOCCHI, SANDRO ; CHIARIELLO, MASSIMO</creatorcontrib><description><![CDATA[The purpose of this study was to evaluate the usefulness of phase analysis in detecting the altered activation sequence induced by different pacing modes. Radionulide ventriculography and planar gated blood pool scintigraphy were performed at rest in 56 patients with different pacemakers. This method permitted us to localize the pacemaker impulse site in the right ventricie and its diffusion in the heart. In patients with VVI pacemaker, this technique showed an evident asynchronism of contraction and relaxation of each ventricle and the standard deviation of phase angle (σ), calculated by computer, is greater during pacing than sinus rhythm for left (LV) and right (RV) ventricles (LV σ: 17°± 4 vs 11°± 3, < 0.001; RV σ: 31°± 7 vs 14°± 4, P < 0.001). In the patients with VVI rate responsive pacemakers, the LV σ changed from 18.5 ± 3 under pacing to 11°± 3 in sinus rhythm, P < 0.001, while the RV σ changed from 30°± 8 to 14°± 4, P < 0.001. Instead in the patients with DDD pacemakers, the LV σ changed from 15.5°± 2 under pacing to 11°± 3 in sinus rhythm, P < 0.05, while the RV cr changed from 29.1°± 6 to 14°± 4, P < 0.001. Besides in patients with VDD pacemakers, the LV σ changed from 14.9°± 3 during pacing to 11°± 3 in sinus rhythm, P < 0.01, and from 27.5°± 5 to 14°± 4 for the right ventricle, P < 0.01. So the technique of Fourier analysis permits us to examine the effects of a temporal inhomogeneity induced by different pacing modes, and it can be utilized to assess the optimal atrioventricular delay in DDD paced patients.]]></description><identifier>ISSN: 0147-8389</identifier><identifier>EISSN: 1540-8159</identifier><identifier>DOI: 10.1111/j.1540-8159.1991.tb02880.x</identifier><identifier>PMID: 1720528</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>cardiac function ; Cardiac Pacing, Artificial - methods ; Cineangiography ; Female ; Fourier Analysis ; Gated Blood-Pool Imaging ; Heart Block - diagnostic imaging ; Heart Block - therapy ; Humans ; Image Processing, Computer-Assisted ; Male ; Middle Aged ; Myocardial Contraction - physiology ; Pacemaker, Artificial ; radionuclide ventriculography ; Sick Sinus Syndrome - diagnostic imaging ; Sick Sinus Syndrome - therapy ; Ventricular Function - physiology</subject><ispartof>Pacing and clinical electrophysiology, 1991-09, Vol.14 (9), p.1351-1358</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4381-84b799305bffef1391844f4956b4310d6f2a5ded2e1fbcc7a903a253a5b1f08c3</citedby><cites>FETCH-LOGICAL-c4381-84b799305bffef1391844f4956b4310d6f2a5ded2e1fbcc7a903a253a5b1f08c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1720528$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>SANTOMAURO, MAURIZIO</creatorcontrib><creatorcontrib>FAZIO, SERAFINO</creatorcontrib><creatorcontrib>FERRARO, SERGIO</creatorcontrib><creatorcontrib>MADDALENA, GIOVANNI</creatorcontrib><creatorcontrib>PAPACCIOLI, GIUSEPPE</creatorcontrib><creatorcontrib>PAPPONE, CARLO</creatorcontrib><creatorcontrib>BETOCCHI, SANDRO</creatorcontrib><creatorcontrib>CHIARIELLO, MASSIMO</creatorcontrib><title>Fourier Analysis in Patients with Different Pacing Modes</title><title>Pacing and clinical electrophysiology</title><addtitle>Pacing Clin Electrophysiol</addtitle><description><![CDATA[The purpose of this study was to evaluate the usefulness of phase analysis in detecting the altered activation sequence induced by different pacing modes. Radionulide ventriculography and planar gated blood pool scintigraphy were performed at rest in 56 patients with different pacemakers. This method permitted us to localize the pacemaker impulse site in the right ventricie and its diffusion in the heart. In patients with VVI pacemaker, this technique showed an evident asynchronism of contraction and relaxation of each ventricle and the standard deviation of phase angle (σ), calculated by computer, is greater during pacing than sinus rhythm for left (LV) and right (RV) ventricles (LV σ: 17°± 4 vs 11°± 3, < 0.001; RV σ: 31°± 7 vs 14°± 4, P < 0.001). In the patients with VVI rate responsive pacemakers, the LV σ changed from 18.5 ± 3 under pacing to 11°± 3 in sinus rhythm, P < 0.001, while the RV σ changed from 30°± 8 to 14°± 4, P < 0.001. Instead in the patients with DDD pacemakers, the LV σ changed from 15.5°± 2 under pacing to 11°± 3 in sinus rhythm, P < 0.05, while the RV cr changed from 29.1°± 6 to 14°± 4, P < 0.001. Besides in patients with VDD pacemakers, the LV σ changed from 14.9°± 3 during pacing to 11°± 3 in sinus rhythm, P < 0.01, and from 27.5°± 5 to 14°± 4 for the right ventricle, P < 0.01. So the technique of Fourier analysis permits us to examine the effects of a temporal inhomogeneity induced by different pacing modes, and it can be utilized to assess the optimal atrioventricular delay in DDD paced patients.]]></description><subject>cardiac function</subject><subject>Cardiac Pacing, Artificial - methods</subject><subject>Cineangiography</subject><subject>Female</subject><subject>Fourier Analysis</subject><subject>Gated Blood-Pool Imaging</subject><subject>Heart Block - diagnostic imaging</subject><subject>Heart Block - therapy</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Myocardial Contraction - physiology</subject><subject>Pacemaker, Artificial</subject><subject>radionuclide ventriculography</subject><subject>Sick Sinus Syndrome - diagnostic imaging</subject><subject>Sick Sinus Syndrome - therapy</subject><subject>Ventricular Function - physiology</subject><issn>0147-8389</issn><issn>1540-8159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1991</creationdate><recordtype>article</recordtype><recordid>eNqVkMtOwzAQRS0EgvL4BKSIBbsET2zHNivaAgXEa8FjaTmJDS5pAnYq2r8nVSpYMxtrfGfOSAehI8AJdHUyTYBRHAtgMgEpIWlznAqBk8UGGvxGm2iAgfJYECF30G4IU4xxhinbRtvAU8xSMUDispl7Z3w0rHW1DC5Ero4edetM3Ybo27Xv0bmz1viu7_4LV79Fd01pwj7asroK5mD97qHny4un8VV8-zC5Hg9v44ISAbGgOZeSYJZ3EAtEgqDUUsmynBLAZWZTzUpTpgZsXhRcS0x0yohmOVgsCrKHjnvup2--5ia0auZCYapK16aZB8VTKmnGeTd42g8WvgnBG6s-vZtpv1SA1UqbmqqVG7Vyo1ba1FqbWnTLh-sr83xmyr_V3lOXn_X5t6vM8h9k9TgcXwBh0CHiHuFCaxa_CO0_VMYJZ-r1fqLGVzc3owl5USPyA8RXi6k</recordid><startdate>199109</startdate><enddate>199109</enddate><creator>SANTOMAURO, MAURIZIO</creator><creator>FAZIO, SERAFINO</creator><creator>FERRARO, SERGIO</creator><creator>MADDALENA, GIOVANNI</creator><creator>PAPACCIOLI, GIUSEPPE</creator><creator>PAPPONE, CARLO</creator><creator>BETOCCHI, SANDRO</creator><creator>CHIARIELLO, MASSIMO</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199109</creationdate><title>Fourier Analysis in Patients with Different Pacing Modes</title><author>SANTOMAURO, MAURIZIO ; FAZIO, SERAFINO ; FERRARO, SERGIO ; MADDALENA, GIOVANNI ; PAPACCIOLI, GIUSEPPE ; PAPPONE, CARLO ; BETOCCHI, SANDRO ; CHIARIELLO, MASSIMO</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4381-84b799305bffef1391844f4956b4310d6f2a5ded2e1fbcc7a903a253a5b1f08c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1991</creationdate><topic>cardiac function</topic><topic>Cardiac Pacing, Artificial - methods</topic><topic>Cineangiography</topic><topic>Female</topic><topic>Fourier Analysis</topic><topic>Gated Blood-Pool Imaging</topic><topic>Heart Block - diagnostic imaging</topic><topic>Heart Block - therapy</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Myocardial Contraction - physiology</topic><topic>Pacemaker, Artificial</topic><topic>radionuclide ventriculography</topic><topic>Sick Sinus Syndrome - diagnostic imaging</topic><topic>Sick Sinus Syndrome - therapy</topic><topic>Ventricular Function - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>SANTOMAURO, MAURIZIO</creatorcontrib><creatorcontrib>FAZIO, SERAFINO</creatorcontrib><creatorcontrib>FERRARO, SERGIO</creatorcontrib><creatorcontrib>MADDALENA, GIOVANNI</creatorcontrib><creatorcontrib>PAPACCIOLI, GIUSEPPE</creatorcontrib><creatorcontrib>PAPPONE, CARLO</creatorcontrib><creatorcontrib>BETOCCHI, SANDRO</creatorcontrib><creatorcontrib>CHIARIELLO, MASSIMO</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Pacing and clinical electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SANTOMAURO, MAURIZIO</au><au>FAZIO, SERAFINO</au><au>FERRARO, SERGIO</au><au>MADDALENA, GIOVANNI</au><au>PAPACCIOLI, GIUSEPPE</au><au>PAPPONE, CARLO</au><au>BETOCCHI, SANDRO</au><au>CHIARIELLO, MASSIMO</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fourier Analysis in Patients with Different Pacing Modes</atitle><jtitle>Pacing and clinical electrophysiology</jtitle><addtitle>Pacing Clin Electrophysiol</addtitle><date>1991-09</date><risdate>1991</risdate><volume>14</volume><issue>9</issue><spage>1351</spage><epage>1358</epage><pages>1351-1358</pages><issn>0147-8389</issn><eissn>1540-8159</eissn><abstract><![CDATA[The purpose of this study was to evaluate the usefulness of phase analysis in detecting the altered activation sequence induced by different pacing modes. Radionulide ventriculography and planar gated blood pool scintigraphy were performed at rest in 56 patients with different pacemakers. This method permitted us to localize the pacemaker impulse site in the right ventricie and its diffusion in the heart. In patients with VVI pacemaker, this technique showed an evident asynchronism of contraction and relaxation of each ventricle and the standard deviation of phase angle (σ), calculated by computer, is greater during pacing than sinus rhythm for left (LV) and right (RV) ventricles (LV σ: 17°± 4 vs 11°± 3, < 0.001; RV σ: 31°± 7 vs 14°± 4, P < 0.001). In the patients with VVI rate responsive pacemakers, the LV σ changed from 18.5 ± 3 under pacing to 11°± 3 in sinus rhythm, P < 0.001, while the RV σ changed from 30°± 8 to 14°± 4, P < 0.001. Instead in the patients with DDD pacemakers, the LV σ changed from 15.5°± 2 under pacing to 11°± 3 in sinus rhythm, P < 0.05, while the RV cr changed from 29.1°± 6 to 14°± 4, P < 0.001. Besides in patients with VDD pacemakers, the LV σ changed from 14.9°± 3 during pacing to 11°± 3 in sinus rhythm, P < 0.01, and from 27.5°± 5 to 14°± 4 for the right ventricle, P < 0.01. So the technique of Fourier analysis permits us to examine the effects of a temporal inhomogeneity induced by different pacing modes, and it can be utilized to assess the optimal atrioventricular delay in DDD paced patients.]]></abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>1720528</pmid><doi>10.1111/j.1540-8159.1991.tb02880.x</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0147-8389 |
ispartof | Pacing and clinical electrophysiology, 1991-09, Vol.14 (9), p.1351-1358 |
issn | 0147-8389 1540-8159 |
language | eng |
recordid | cdi_proquest_miscellaneous_72494677 |
source | SPORTDiscus with Full Text |
subjects | cardiac function Cardiac Pacing, Artificial - methods Cineangiography Female Fourier Analysis Gated Blood-Pool Imaging Heart Block - diagnostic imaging Heart Block - therapy Humans Image Processing, Computer-Assisted Male Middle Aged Myocardial Contraction - physiology Pacemaker, Artificial radionuclide ventriculography Sick Sinus Syndrome - diagnostic imaging Sick Sinus Syndrome - therapy Ventricular Function - physiology |
title | Fourier Analysis in Patients with Different Pacing Modes |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T13%3A45%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fourier%20Analysis%20in%20Patients%20with%20Different%20Pacing%20Modes&rft.jtitle=Pacing%20and%20clinical%20electrophysiology&rft.au=SANTOMAURO,%20MAURIZIO&rft.date=1991-09&rft.volume=14&rft.issue=9&rft.spage=1351&rft.epage=1358&rft.pages=1351-1358&rft.issn=0147-8389&rft.eissn=1540-8159&rft_id=info:doi/10.1111/j.1540-8159.1991.tb02880.x&rft_dat=%3Cproquest_cross%3E72494677%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4381-84b799305bffef1391844f4956b4310d6f2a5ded2e1fbcc7a903a253a5b1f08c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=72494677&rft_id=info:pmid/1720528&rfr_iscdi=true |