Direct measurement of hepatic blood flow in native and transplanted organs, with accompanying systemic hemodynamics

The purpose of this study was to investigate intraoperatively a population of patients with end‐stage liver disease before and after liver transplantation with respect to (a) the range of hepatic and systemic hemodynamics and their changes associated with transplantation and (b) the ability to ident...

Full description

Saved in:
Bibliographic Details
Published in:Hepatology (Baltimore, Md.) Md.), 1992-07, Vol.16 (1), p.100-111
Main Authors: Paulsen, A. William, Klintmalm, Goran B. G.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4098-9feb5d91afb284c97550cd7cfe6d5e11f4c1b3eba31d48ff8d48519be7e35c1a3
cites cdi_FETCH-LOGICAL-c4098-9feb5d91afb284c97550cd7cfe6d5e11f4c1b3eba31d48ff8d48519be7e35c1a3
container_end_page 111
container_issue 1
container_start_page 100
container_title Hepatology (Baltimore, Md.)
container_volume 16
creator Paulsen, A. William
Klintmalm, Goran B. G.
description The purpose of this study was to investigate intraoperatively a population of patients with end‐stage liver disease before and after liver transplantation with respect to (a) the range of hepatic and systemic hemodynamics and their changes associated with transplantation and (b) the ability to identify native hemodynamic correlates with specific diagnostic groups. Hepatic artery and portal vein blood flows were determined with square‐wave electromagnetic flowmetry. Significant differences related to the type of preservation solution used–Euro‐Collins or University of Wisconsin–were identified in some hepatic and systemic hemodynamic measurements from the graft livers. Specifically, cardiac output, total liver blood flow and liver weight were significantly increased in the Euro‐Collins group compared with the native and University of Wisconsin groups. Hepatic artery flow was significantly greater and portal vein pressure was significantly lower in the University of Wisconsin group than in the native or Euro‐Collins group. In general, comparing the graft and native livers, hepatic artery and portal vein blood flow increased significantly after transplantation, as did hepatic oxygen consumption. Portal vein pressures were dramatically reduced, but systemic arterial pressure remained remarkably constant. The percentage of cardiac output going to the liver increased, as did the portal vein percentage of the total liver blood flow. Diagnostic groups could not clearly be associated with characteristic native liver or systemic hemodynamics. Hemodynamics may be associated more with the stage of the disease process than the disease itself. (HEPATOLOGY 1992;16:100–111.)
doi_str_mv 10.1002/hep.1840160118
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73038050</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73038050</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4098-9feb5d91afb284c97550cd7cfe6d5e11f4c1b3eba31d48ff8d48519be7e35c1a3</originalsourceid><addsrcrecordid>eNqFkE1v1DAQhi1EVbYfV25IPiBOZBnHcWIfUSltpUpwgHPk2OOuUWIHO8sq_x6jXVFuXPw1z7wePYS8ZrBlAPWHHc5bJhtgLTAmX5ANE3VXcS7gJdlA3UGlGFevyEXOPwBANbU8J-esLT1tsyH5k09oFjqhzvuEE4aFRkdLql68ocMYo6VujAfqAw3l7RdSHSxdkg55HnVY0NKYnsrtPT34ZUe1MXGadVh9eKJ5zQtOJWiHU7Rr0OWcr8iZ02PG69N-Sb5_vv12c189frl7uPn4WJkGlKyUw0FYxbQbatkY1QkBxnbGYWsFMuYawwaOg-bMNtI5WVbB1IAdcmGY5pfk3TF3TvHnHvPSTz4bHMvUGPe57zhwCQIKuD2CJsWcE7p-Tn7Sae0Z9H8s98VH_2y5NLw5Je-HCe0zftRa6m9PdZ2NHl2RZXz-i4kWuk6qgqkjdvAjrv_5tL-__frPCL8BkZaYmA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73038050</pqid></control><display><type>article</type><title>Direct measurement of hepatic blood flow in native and transplanted organs, with accompanying systemic hemodynamics</title><source>Alma/SFX Local Collection</source><creator>Paulsen, A. William ; Klintmalm, Goran B. G.</creator><creatorcontrib>Paulsen, A. William ; Klintmalm, Goran B. G.</creatorcontrib><description>The purpose of this study was to investigate intraoperatively a population of patients with end‐stage liver disease before and after liver transplantation with respect to (a) the range of hepatic and systemic hemodynamics and their changes associated with transplantation and (b) the ability to identify native hemodynamic correlates with specific diagnostic groups. Hepatic artery and portal vein blood flows were determined with square‐wave electromagnetic flowmetry. Significant differences related to the type of preservation solution used–Euro‐Collins or University of Wisconsin–were identified in some hepatic and systemic hemodynamic measurements from the graft livers. Specifically, cardiac output, total liver blood flow and liver weight were significantly increased in the Euro‐Collins group compared with the native and University of Wisconsin groups. Hepatic artery flow was significantly greater and portal vein pressure was significantly lower in the University of Wisconsin group than in the native or Euro‐Collins group. In general, comparing the graft and native livers, hepatic artery and portal vein blood flow increased significantly after transplantation, as did hepatic oxygen consumption. Portal vein pressures were dramatically reduced, but systemic arterial pressure remained remarkably constant. The percentage of cardiac output going to the liver increased, as did the portal vein percentage of the total liver blood flow. Diagnostic groups could not clearly be associated with characteristic native liver or systemic hemodynamics. Hemodynamics may be associated more with the stage of the disease process than the disease itself. (HEPATOLOGY 1992;16:100–111.)</description><identifier>ISSN: 0270-9139</identifier><identifier>EISSN: 1527-3350</identifier><identifier>DOI: 10.1002/hep.1840160118</identifier><identifier>PMID: 1618464</identifier><identifier>CODEN: HPTLD9</identifier><language>eng</language><publisher>Philadelphia, PA: W.B. Saunders</publisher><subject>Adult ; Analysis of Variance ; Biological and medical sciences ; Blood Pressure ; Cardiac Output ; Hemodynamics ; Hepatic Artery - physiopathology ; Humans ; Liver Circulation ; Liver Transplantation - physiology ; Medical sciences ; Portal System - physiopathology ; Portal Vein - physiopathology ; Probability ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Surgery of the digestive system ; Vascular Resistance</subject><ispartof>Hepatology (Baltimore, Md.), 1992-07, Vol.16 (1), p.100-111</ispartof><rights>Copyright © 1992 American Association for the Study of Liver Diseases</rights><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4098-9feb5d91afb284c97550cd7cfe6d5e11f4c1b3eba31d48ff8d48519be7e35c1a3</citedby><cites>FETCH-LOGICAL-c4098-9feb5d91afb284c97550cd7cfe6d5e11f4c1b3eba31d48ff8d48519be7e35c1a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=5607789$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1618464$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Paulsen, A. William</creatorcontrib><creatorcontrib>Klintmalm, Goran B. G.</creatorcontrib><title>Direct measurement of hepatic blood flow in native and transplanted organs, with accompanying systemic hemodynamics</title><title>Hepatology (Baltimore, Md.)</title><addtitle>Hepatology</addtitle><description>The purpose of this study was to investigate intraoperatively a population of patients with end‐stage liver disease before and after liver transplantation with respect to (a) the range of hepatic and systemic hemodynamics and their changes associated with transplantation and (b) the ability to identify native hemodynamic correlates with specific diagnostic groups. Hepatic artery and portal vein blood flows were determined with square‐wave electromagnetic flowmetry. Significant differences related to the type of preservation solution used–Euro‐Collins or University of Wisconsin–were identified in some hepatic and systemic hemodynamic measurements from the graft livers. Specifically, cardiac output, total liver blood flow and liver weight were significantly increased in the Euro‐Collins group compared with the native and University of Wisconsin groups. Hepatic artery flow was significantly greater and portal vein pressure was significantly lower in the University of Wisconsin group than in the native or Euro‐Collins group. In general, comparing the graft and native livers, hepatic artery and portal vein blood flow increased significantly after transplantation, as did hepatic oxygen consumption. Portal vein pressures were dramatically reduced, but systemic arterial pressure remained remarkably constant. The percentage of cardiac output going to the liver increased, as did the portal vein percentage of the total liver blood flow. Diagnostic groups could not clearly be associated with characteristic native liver or systemic hemodynamics. Hemodynamics may be associated more with the stage of the disease process than the disease itself. (HEPATOLOGY 1992;16:100–111.)</description><subject>Adult</subject><subject>Analysis of Variance</subject><subject>Biological and medical sciences</subject><subject>Blood Pressure</subject><subject>Cardiac Output</subject><subject>Hemodynamics</subject><subject>Hepatic Artery - physiopathology</subject><subject>Humans</subject><subject>Liver Circulation</subject><subject>Liver Transplantation - physiology</subject><subject>Medical sciences</subject><subject>Portal System - physiopathology</subject><subject>Portal Vein - physiopathology</subject><subject>Probability</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Surgery of the digestive system</subject><subject>Vascular Resistance</subject><issn>0270-9139</issn><issn>1527-3350</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><recordid>eNqFkE1v1DAQhi1EVbYfV25IPiBOZBnHcWIfUSltpUpwgHPk2OOuUWIHO8sq_x6jXVFuXPw1z7wePYS8ZrBlAPWHHc5bJhtgLTAmX5ANE3VXcS7gJdlA3UGlGFevyEXOPwBANbU8J-esLT1tsyH5k09oFjqhzvuEE4aFRkdLql68ocMYo6VujAfqAw3l7RdSHSxdkg55HnVY0NKYnsrtPT34ZUe1MXGadVh9eKJ5zQtOJWiHU7Rr0OWcr8iZ02PG69N-Sb5_vv12c189frl7uPn4WJkGlKyUw0FYxbQbatkY1QkBxnbGYWsFMuYawwaOg-bMNtI5WVbB1IAdcmGY5pfk3TF3TvHnHvPSTz4bHMvUGPe57zhwCQIKuD2CJsWcE7p-Tn7Sae0Z9H8s98VH_2y5NLw5Je-HCe0zftRa6m9PdZ2NHl2RZXz-i4kWuk6qgqkjdvAjrv_5tL-__frPCL8BkZaYmA</recordid><startdate>199207</startdate><enddate>199207</enddate><creator>Paulsen, A. William</creator><creator>Klintmalm, Goran B. G.</creator><general>W.B. Saunders</general><general>Wiley</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199207</creationdate><title>Direct measurement of hepatic blood flow in native and transplanted organs, with accompanying systemic hemodynamics</title><author>Paulsen, A. William ; Klintmalm, Goran B. G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4098-9feb5d91afb284c97550cd7cfe6d5e11f4c1b3eba31d48ff8d48519be7e35c1a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Adult</topic><topic>Analysis of Variance</topic><topic>Biological and medical sciences</topic><topic>Blood Pressure</topic><topic>Cardiac Output</topic><topic>Hemodynamics</topic><topic>Hepatic Artery - physiopathology</topic><topic>Humans</topic><topic>Liver Circulation</topic><topic>Liver Transplantation - physiology</topic><topic>Medical sciences</topic><topic>Portal System - physiopathology</topic><topic>Portal Vein - physiopathology</topic><topic>Probability</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Surgery of the digestive system</topic><topic>Vascular Resistance</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Paulsen, A. William</creatorcontrib><creatorcontrib>Klintmalm, Goran B. G.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Hepatology (Baltimore, Md.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Paulsen, A. William</au><au>Klintmalm, Goran B. G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Direct measurement of hepatic blood flow in native and transplanted organs, with accompanying systemic hemodynamics</atitle><jtitle>Hepatology (Baltimore, Md.)</jtitle><addtitle>Hepatology</addtitle><date>1992-07</date><risdate>1992</risdate><volume>16</volume><issue>1</issue><spage>100</spage><epage>111</epage><pages>100-111</pages><issn>0270-9139</issn><eissn>1527-3350</eissn><coden>HPTLD9</coden><abstract>The purpose of this study was to investigate intraoperatively a population of patients with end‐stage liver disease before and after liver transplantation with respect to (a) the range of hepatic and systemic hemodynamics and their changes associated with transplantation and (b) the ability to identify native hemodynamic correlates with specific diagnostic groups. Hepatic artery and portal vein blood flows were determined with square‐wave electromagnetic flowmetry. Significant differences related to the type of preservation solution used–Euro‐Collins or University of Wisconsin–were identified in some hepatic and systemic hemodynamic measurements from the graft livers. Specifically, cardiac output, total liver blood flow and liver weight were significantly increased in the Euro‐Collins group compared with the native and University of Wisconsin groups. Hepatic artery flow was significantly greater and portal vein pressure was significantly lower in the University of Wisconsin group than in the native or Euro‐Collins group. In general, comparing the graft and native livers, hepatic artery and portal vein blood flow increased significantly after transplantation, as did hepatic oxygen consumption. Portal vein pressures were dramatically reduced, but systemic arterial pressure remained remarkably constant. The percentage of cardiac output going to the liver increased, as did the portal vein percentage of the total liver blood flow. Diagnostic groups could not clearly be associated with characteristic native liver or systemic hemodynamics. Hemodynamics may be associated more with the stage of the disease process than the disease itself. (HEPATOLOGY 1992;16:100–111.)</abstract><cop>Philadelphia, PA</cop><pub>W.B. Saunders</pub><pmid>1618464</pmid><doi>10.1002/hep.1840160118</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0270-9139
ispartof Hepatology (Baltimore, Md.), 1992-07, Vol.16 (1), p.100-111
issn 0270-9139
1527-3350
language eng
recordid cdi_proquest_miscellaneous_73038050
source Alma/SFX Local Collection
subjects Adult
Analysis of Variance
Biological and medical sciences
Blood Pressure
Cardiac Output
Hemodynamics
Hepatic Artery - physiopathology
Humans
Liver Circulation
Liver Transplantation - physiology
Medical sciences
Portal System - physiopathology
Portal Vein - physiopathology
Probability
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Surgery of the digestive system
Vascular Resistance
title Direct measurement of hepatic blood flow in native and transplanted organs, with accompanying systemic hemodynamics
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T07%3A34%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Direct%20measurement%20of%20hepatic%20blood%20flow%20in%20native%20and%20transplanted%20organs,%20with%20accompanying%20systemic%20hemodynamics&rft.jtitle=Hepatology%20(Baltimore,%20Md.)&rft.au=Paulsen,%20A.%20William&rft.date=1992-07&rft.volume=16&rft.issue=1&rft.spage=100&rft.epage=111&rft.pages=100-111&rft.issn=0270-9139&rft.eissn=1527-3350&rft.coden=HPTLD9&rft_id=info:doi/10.1002/hep.1840160118&rft_dat=%3Cproquest_cross%3E73038050%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4098-9feb5d91afb284c97550cd7cfe6d5e11f4c1b3eba31d48ff8d48519be7e35c1a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=73038050&rft_id=info:pmid/1618464&rfr_iscdi=true