Loading…

The oxygen uptake response running to exhaustion at peak treadmill speed

Peak treadmill speed (V(max)), which is the final speed reached and sustained for a minute during a speed-incremented continuous maximal oxygen uptake ([OV0312]O(2max)) test, is an effective predictor of endurance performance. This study assesses the reliability of V(max) and [OV0312]O(2max), and ex...

Full description

Saved in:
Bibliographic Details
Published in:Medicine and science in sports and exercise 2003-04, Vol.35 (4), p.663-668
Main Authors: HARLING, Simon A, TONG, Richard J, MICKLEBOROUGH, Timothy D
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Peak treadmill speed (V(max)), which is the final speed reached and sustained for a minute during a speed-incremented continuous maximal oxygen uptake ([OV0312]O(2max)) test, is an effective predictor of endurance performance. This study assesses the reliability of V(max) and [OV0312]O(2max), and examines the oxygen uptake response while running to exhaustion at V(max). Eleven recreationally active runners completed two speed-incremented [OV0312]O(2max) tests (test 1 and test 2) to determine [OV0312]O(2max) and V(max). In addition, the subjects completed a constant speed test (test 3) at V(max) to determine time to exhaustion (T(max)). No significant differences existed between test 1 and test 2 for [OV0312]O(2max) (P = 0.68) and V(max) (P = 0.10). Means (+/- SD) for [OV0312]O(2max) and V(max) were 51.1 +/- 5.8 mL.kg-1.min-1 and 17.4 +/- 1.3 km.h-1, respectively; 95% limits of agreement for V(max) were -0.1 +/- 1.4 km.h-1. However, as heteroscedasticity was present in the [OV0312]O(2max) test data, 95% ratio limits of agreement were reported (1.01 *// 1.08). During test 3, 6 of the 11 subjects attained an oxygen uptake equivalent to their previously recorded [OV0312]O(2max). The time to attain [OV0312]O(2max) was 155.0 +/- 48.0 s, which represented 66.5% of T(max) (237.0 +/- 35.0 s). Although 5 of the 11 subjects did not attain an oxygen uptake response equivalent to that previously recorded, no significant difference existed between the oxygen uptakes for the three tests (P = 0.52). The results of this study indicate that V(max) and [OV0312]O(2max) attained during a speed incremented maximal oxygen uptake test were reliable. However, while running at V(max), not all the subjects attained an oxygen uptake response equivalent to that previously recorded during incremental tests 1 and 2.
ISSN:0195-9131
1530-0315
DOI:10.1249/01.MSS.0000058434.53664.EC