Reproducibility of OCT/SLO Measurements in Healthy Eyes

Purpose. To determine the reproducibility of optical coherence tomography/scanning laser ophthalmoscope (OCT/SLO) measurements within and between observers and within and between sessions in healthy eyes. Methods. Forty eyes of 40 healthy volunteers recruited from the outpatient service of the Depar...

Full description

Saved in:
Bibliographic Details
Published in:European journal of ophthalmology 2010-05, Vol.20 (3), p.552-558
Main Authors: Labiris, Georgios, Giarmoukakis, Athanassios, Katsanos, Andreas, Gkika, Maria G., Fanariotis, Michael, Pavlidou, Efi, Kozobolis, Vassilios P.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c342t-73427f4a430dc66fa59b4036c4b8a12141743007f9f63a532358f24b915d77763
cites cdi_FETCH-LOGICAL-c342t-73427f4a430dc66fa59b4036c4b8a12141743007f9f63a532358f24b915d77763
container_end_page 558
container_issue 3
container_start_page 552
container_title European journal of ophthalmology
container_volume 20
creator Labiris, Georgios
Giarmoukakis, Athanassios
Katsanos, Andreas
Gkika, Maria G.
Fanariotis, Michael
Pavlidou, Efi
Kozobolis, Vassilios P.
description Purpose. To determine the reproducibility of optical coherence tomography/scanning laser ophthalmoscope (OCT/SLO) measurements within and between observers and within and between sessions in healthy eyes. Methods. Forty eyes of 40 healthy volunteers recruited from the outpatient service of the Department of Ophthalmology at the University Hospital of Alexandroupolis, Greece, were included. Retinal thickness scans were performed 3 times by two experienced operators within each of 3 sessions, which took place within a month, using the spectral OCT/SLO. The OCT/SLO provides retinal nerve fiber layer (RNFL) thickness and volume measurements and a 3D tomography analysis of optic nerve head. Statistical analysis was conducted using Bland-Altman plots, coefficient of variation (CoV), and intra-class correlation coefficient (ICC). Results. AS shown by the CoV values, RNFL parameters were generally found to have high reproducibility (CoV ranging from 4.3% to 10.9% for both operators), whereas optic disc parameters had scores reaching up to 22.5%. On the other hand, as shown by the ICC values, intraobserver and interobserver reproducibility for the OCT/SLO was high for optic disc parameters but low for RNFL thickness and volume measurements. Interobserver reproducibility was found to be highest for the maximum cup depth parameter and lowest for the superior volume. Bland-Altman plots indicate that bias is minimal for practically all parameters and scatterplot homoscedasticity is high. Conclusions. According to our data, SLO/OCT generally has a good reproducibility profile, as differences between the two operators were small. However, additional studies on the reproducibility of measurements with the OCT/SLO are needed.
doi_str_mv 10.1177/112067211002000303
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733132284</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_112067211002000303</sage_id><sourcerecordid>733132284</sourcerecordid><originalsourceid>FETCH-LOGICAL-c342t-73427f4a430dc66fa59b4036c4b8a12141743007f9f63a532358f24b915d77763</originalsourceid><addsrcrecordid>eNp9kE9PwzAMxSMEYmPwBTig3jiV2UmarEc0bQxpaBKMc5S2CXTqn5G0h357Mm1wQeJiW_LvPdmPkFuEB0Qpp4gUhKSIABQAGLAzMkZJeSwAxXmYAxAfiBG58n53wFJOL8ko4EymkI6JfDV71xZ9XmZlVXZD1NpoM99O39ab6MVo3ztTm6bzUdlEK6Or7nOIFoPx1-TC6sqbm1OfkPflYjtfxevN0_P8cR3njNMulqFKyzVnUORCWJ2kGQcmcp7NNFLkKMMKpE2tYDphlCUzS3mWYlJIKQWbkPujb7jyqze-U3Xpc1NVujFt75VkDBmlMx5IeiRz13rvjFV7V9baDQpBHfJSf_MKoruTfZ_VpviV_AQUgOkR8PrDqF3buya8-5_lN3BmbtU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733132284</pqid></control><display><type>article</type><title>Reproducibility of OCT/SLO Measurements in Healthy Eyes</title><source>SAGE</source><creator>Labiris, Georgios ; Giarmoukakis, Athanassios ; Katsanos, Andreas ; Gkika, Maria G. ; Fanariotis, Michael ; Pavlidou, Efi ; Kozobolis, Vassilios P.</creator><creatorcontrib>Labiris, Georgios ; Giarmoukakis, Athanassios ; Katsanos, Andreas ; Gkika, Maria G. ; Fanariotis, Michael ; Pavlidou, Efi ; Kozobolis, Vassilios P.</creatorcontrib><description>Purpose. To determine the reproducibility of optical coherence tomography/scanning laser ophthalmoscope (OCT/SLO) measurements within and between observers and within and between sessions in healthy eyes. Methods. Forty eyes of 40 healthy volunteers recruited from the outpatient service of the Department of Ophthalmology at the University Hospital of Alexandroupolis, Greece, were included. Retinal thickness scans were performed 3 times by two experienced operators within each of 3 sessions, which took place within a month, using the spectral OCT/SLO. The OCT/SLO provides retinal nerve fiber layer (RNFL) thickness and volume measurements and a 3D tomography analysis of optic nerve head. Statistical analysis was conducted using Bland-Altman plots, coefficient of variation (CoV), and intra-class correlation coefficient (ICC). Results. AS shown by the CoV values, RNFL parameters were generally found to have high reproducibility (CoV ranging from 4.3% to 10.9% for both operators), whereas optic disc parameters had scores reaching up to 22.5%. On the other hand, as shown by the ICC values, intraobserver and interobserver reproducibility for the OCT/SLO was high for optic disc parameters but low for RNFL thickness and volume measurements. Interobserver reproducibility was found to be highest for the maximum cup depth parameter and lowest for the superior volume. Bland-Altman plots indicate that bias is minimal for practically all parameters and scatterplot homoscedasticity is high. Conclusions. According to our data, SLO/OCT generally has a good reproducibility profile, as differences between the two operators were small. However, additional studies on the reproducibility of measurements with the OCT/SLO are needed.</description><identifier>ISSN: 1120-6721</identifier><identifier>EISSN: 1724-6016</identifier><identifier>DOI: 10.1177/112067211002000303</identifier><identifier>PMID: 20037909</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Cross-Sectional Studies ; Female ; Fourier Analysis ; Humans ; Imaging, Three-Dimensional ; Male ; Middle Aged ; Nerve Fibers ; Observer Variation ; Ophthalmoscopes ; Optic Disk - anatomy &amp; histology ; Prospective Studies ; Reference Values ; Reproducibility of Results ; Retinal Ganglion Cells - cytology ; Tomography, Optical Coherence</subject><ispartof>European journal of ophthalmology, 2010-05, Vol.20 (3), p.552-558</ispartof><rights>2010 SAGE Publications</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c342t-73427f4a430dc66fa59b4036c4b8a12141743007f9f63a532358f24b915d77763</citedby><cites>FETCH-LOGICAL-c342t-73427f4a430dc66fa59b4036c4b8a12141743007f9f63a532358f24b915d77763</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925,79364</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20037909$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Labiris, Georgios</creatorcontrib><creatorcontrib>Giarmoukakis, Athanassios</creatorcontrib><creatorcontrib>Katsanos, Andreas</creatorcontrib><creatorcontrib>Gkika, Maria G.</creatorcontrib><creatorcontrib>Fanariotis, Michael</creatorcontrib><creatorcontrib>Pavlidou, Efi</creatorcontrib><creatorcontrib>Kozobolis, Vassilios P.</creatorcontrib><title>Reproducibility of OCT/SLO Measurements in Healthy Eyes</title><title>European journal of ophthalmology</title><addtitle>Eur J Ophthalmol</addtitle><description>Purpose. To determine the reproducibility of optical coherence tomography/scanning laser ophthalmoscope (OCT/SLO) measurements within and between observers and within and between sessions in healthy eyes. Methods. Forty eyes of 40 healthy volunteers recruited from the outpatient service of the Department of Ophthalmology at the University Hospital of Alexandroupolis, Greece, were included. Retinal thickness scans were performed 3 times by two experienced operators within each of 3 sessions, which took place within a month, using the spectral OCT/SLO. The OCT/SLO provides retinal nerve fiber layer (RNFL) thickness and volume measurements and a 3D tomography analysis of optic nerve head. Statistical analysis was conducted using Bland-Altman plots, coefficient of variation (CoV), and intra-class correlation coefficient (ICC). Results. AS shown by the CoV values, RNFL parameters were generally found to have high reproducibility (CoV ranging from 4.3% to 10.9% for both operators), whereas optic disc parameters had scores reaching up to 22.5%. On the other hand, as shown by the ICC values, intraobserver and interobserver reproducibility for the OCT/SLO was high for optic disc parameters but low for RNFL thickness and volume measurements. Interobserver reproducibility was found to be highest for the maximum cup depth parameter and lowest for the superior volume. Bland-Altman plots indicate that bias is minimal for practically all parameters and scatterplot homoscedasticity is high. Conclusions. According to our data, SLO/OCT generally has a good reproducibility profile, as differences between the two operators were small. However, additional studies on the reproducibility of measurements with the OCT/SLO are needed.</description><subject>Cross-Sectional Studies</subject><subject>Female</subject><subject>Fourier Analysis</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Nerve Fibers</subject><subject>Observer Variation</subject><subject>Ophthalmoscopes</subject><subject>Optic Disk - anatomy &amp; histology</subject><subject>Prospective Studies</subject><subject>Reference Values</subject><subject>Reproducibility of Results</subject><subject>Retinal Ganglion Cells - cytology</subject><subject>Tomography, Optical Coherence</subject><issn>1120-6721</issn><issn>1724-6016</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9kE9PwzAMxSMEYmPwBTig3jiV2UmarEc0bQxpaBKMc5S2CXTqn5G0h357Mm1wQeJiW_LvPdmPkFuEB0Qpp4gUhKSIABQAGLAzMkZJeSwAxXmYAxAfiBG58n53wFJOL8ko4EymkI6JfDV71xZ9XmZlVXZD1NpoM99O39ab6MVo3ztTm6bzUdlEK6Or7nOIFoPx1-TC6sqbm1OfkPflYjtfxevN0_P8cR3njNMulqFKyzVnUORCWJ2kGQcmcp7NNFLkKMMKpE2tYDphlCUzS3mWYlJIKQWbkPujb7jyqze-U3Xpc1NVujFt75VkDBmlMx5IeiRz13rvjFV7V9baDQpBHfJSf_MKoruTfZ_VpviV_AQUgOkR8PrDqF3buya8-5_lN3BmbtU</recordid><startdate>20100501</startdate><enddate>20100501</enddate><creator>Labiris, Georgios</creator><creator>Giarmoukakis, Athanassios</creator><creator>Katsanos, Andreas</creator><creator>Gkika, Maria G.</creator><creator>Fanariotis, Michael</creator><creator>Pavlidou, Efi</creator><creator>Kozobolis, Vassilios P.</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20100501</creationdate><title>Reproducibility of OCT/SLO Measurements in Healthy Eyes</title><author>Labiris, Georgios ; Giarmoukakis, Athanassios ; Katsanos, Andreas ; Gkika, Maria G. ; Fanariotis, Michael ; Pavlidou, Efi ; Kozobolis, Vassilios P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c342t-73427f4a430dc66fa59b4036c4b8a12141743007f9f63a532358f24b915d77763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Cross-Sectional Studies</topic><topic>Female</topic><topic>Fourier Analysis</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Nerve Fibers</topic><topic>Observer Variation</topic><topic>Ophthalmoscopes</topic><topic>Optic Disk - anatomy &amp; histology</topic><topic>Prospective Studies</topic><topic>Reference Values</topic><topic>Reproducibility of Results</topic><topic>Retinal Ganglion Cells - cytology</topic><topic>Tomography, Optical Coherence</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Labiris, Georgios</creatorcontrib><creatorcontrib>Giarmoukakis, Athanassios</creatorcontrib><creatorcontrib>Katsanos, Andreas</creatorcontrib><creatorcontrib>Gkika, Maria G.</creatorcontrib><creatorcontrib>Fanariotis, Michael</creatorcontrib><creatorcontrib>Pavlidou, Efi</creatorcontrib><creatorcontrib>Kozobolis, Vassilios P.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of ophthalmology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Labiris, Georgios</au><au>Giarmoukakis, Athanassios</au><au>Katsanos, Andreas</au><au>Gkika, Maria G.</au><au>Fanariotis, Michael</au><au>Pavlidou, Efi</au><au>Kozobolis, Vassilios P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reproducibility of OCT/SLO Measurements in Healthy Eyes</atitle><jtitle>European journal of ophthalmology</jtitle><addtitle>Eur J Ophthalmol</addtitle><date>2010-05-01</date><risdate>2010</risdate><volume>20</volume><issue>3</issue><spage>552</spage><epage>558</epage><pages>552-558</pages><issn>1120-6721</issn><eissn>1724-6016</eissn><abstract>Purpose. To determine the reproducibility of optical coherence tomography/scanning laser ophthalmoscope (OCT/SLO) measurements within and between observers and within and between sessions in healthy eyes. Methods. Forty eyes of 40 healthy volunteers recruited from the outpatient service of the Department of Ophthalmology at the University Hospital of Alexandroupolis, Greece, were included. Retinal thickness scans were performed 3 times by two experienced operators within each of 3 sessions, which took place within a month, using the spectral OCT/SLO. The OCT/SLO provides retinal nerve fiber layer (RNFL) thickness and volume measurements and a 3D tomography analysis of optic nerve head. Statistical analysis was conducted using Bland-Altman plots, coefficient of variation (CoV), and intra-class correlation coefficient (ICC). Results. AS shown by the CoV values, RNFL parameters were generally found to have high reproducibility (CoV ranging from 4.3% to 10.9% for both operators), whereas optic disc parameters had scores reaching up to 22.5%. On the other hand, as shown by the ICC values, intraobserver and interobserver reproducibility for the OCT/SLO was high for optic disc parameters but low for RNFL thickness and volume measurements. Interobserver reproducibility was found to be highest for the maximum cup depth parameter and lowest for the superior volume. Bland-Altman plots indicate that bias is minimal for practically all parameters and scatterplot homoscedasticity is high. Conclusions. According to our data, SLO/OCT generally has a good reproducibility profile, as differences between the two operators were small. However, additional studies on the reproducibility of measurements with the OCT/SLO are needed.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>20037909</pmid><doi>10.1177/112067211002000303</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1120-6721
ispartof European journal of ophthalmology, 2010-05, Vol.20 (3), p.552-558
issn 1120-6721
1724-6016
language eng
recordid cdi_proquest_miscellaneous_733132284
source SAGE
subjects Cross-Sectional Studies
Female
Fourier Analysis
Humans
Imaging, Three-Dimensional
Male
Middle Aged
Nerve Fibers
Observer Variation
Ophthalmoscopes
Optic Disk - anatomy & histology
Prospective Studies
Reference Values
Reproducibility of Results
Retinal Ganglion Cells - cytology
Tomography, Optical Coherence
title Reproducibility of OCT/SLO Measurements in Healthy Eyes
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T19%3A26%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reproducibility%20of%20OCT/SLO%20Measurements%20in%20Healthy%20Eyes&rft.jtitle=European%20journal%20of%20ophthalmology&rft.au=Labiris,%20Georgios&rft.date=2010-05-01&rft.volume=20&rft.issue=3&rft.spage=552&rft.epage=558&rft.pages=552-558&rft.issn=1120-6721&rft.eissn=1724-6016&rft_id=info:doi/10.1177/112067211002000303&rft_dat=%3Cproquest_cross%3E733132284%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c342t-73427f4a430dc66fa59b4036c4b8a12141743007f9f63a532358f24b915d77763%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=733132284&rft_id=info:pmid/20037909&rft_sage_id=10.1177_112067211002000303&rfr_iscdi=true