Loading…

Assessment of Hydrodissection, Holmium:YAG Laser Vaporization of Renal Tissue, and Both Combined To Facilitate Laparoscopic Partial Nephrectomy in Porcine Model

Objectives To evaluate the modalities of electrocautery, holmium:yttrium-aluminum-garnet (YAG) laser, hydrodissection, and combined holmium:YAG laser with hydrodissection applied to laparoscopic partial nephrectomy (LPN) in a porcine model. Methods A total of 16 Yorkshire pigs were divided into 4 eq...

Full description

Saved in:
Bibliographic Details
Published in:Urology (Ridgewood, N.J.) N.J.), 2010-05, Vol.75 (5), p.1209-1212
Main Authors: Knudsen, Bodo E, Chew, Ben H, Tan, Andrew H, Beiko, Darren T, Denstedt, John D, Pautler, Stephen E
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objectives To evaluate the modalities of electrocautery, holmium:yttrium-aluminum-garnet (YAG) laser, hydrodissection, and combined holmium:YAG laser with hydrodissection applied to laparoscopic partial nephrectomy (LPN) in a porcine model. Methods A total of 16 Yorkshire pigs were divided into 4 equal groups (electrocautery, hydrodissection, holmium:YAG laser, and combined hydrodissection/holmium:YAG laser) and underwent unilateral LPN. The total operative time, partial nephrectomy time, hemostasis modality, and intraoperative complications were recorded. The pre- and postoperative hemoglobin was measured. Abdominal computed tomography was performed 2 weeks postoperatively. Representative specimens from each arm were examined for histologic findings. Results The mean total operative time and the time to perform partial nephrectomy was lower for the combined hydrodissection/holmium:YAG laser arm (66 minutes and 13 minutes, respectively) compared with the electrocautery arm (93 and 30 minutes, respectively), holmium:YAG laser-only arm (77 and 19 minutes, respectively), and hydrodissection-only arm (129 and 35 minutes, respectively). The mean decrease in hemoglobin was the least for the combined hydrodissection/holmium:YAG laser arm (5.3 g/L) followed by the holmium:YAG-only (15.3 g/L), hydrodissection-only (16.8 g/L), and electrocautery (35.5 g/L) arms, respectively. The histologic examination demonstrated an increased depth of tissue injury in the electrocautery arm. Conclusions In a porcine model, the combined use of the hydrodissection/holmium:YAG laser to perform LPN had the shortest operative time and the lowest decrease in hemoglobin and appears to warrant additional clinical evaluation in human trials for LPN.
ISSN:0090-4295
1527-9995