Loading…

Atrial activation time and pattern of linear triple-site vs. single-site atrial pacing after cardioversion in patients with atrial fibrillation

Multisite atrial pacing has been suggested to be effective in suppressing atrial fibrillation (AF), however, the effect of linear triple-site atrial pacing (LTSP) in humans has not been evaluated. We compared the effects of LTSP to single-site atrial pacing (SSP) on the atrial activation and wavefro...

Full description

Saved in:
Bibliographic Details
Published in:Europace (London, England) England), 2010-04, Vol.12 (4), p.508-516
Main Authors: Choi, Jong-Il, Ryu, Kyungmoo, Park, Euljoon, Benser, Michael E, Jang, Jin Kun, Lee, Hyun Soo, Lim, Hong Euy, Pak, Hui-Nam, Kim, Young-Hoon
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c337t-d74995e990c7e4674d672e6b235e04b2ad3d8c73a49ed9a2999dc6ad1c00a40b3
cites cdi_FETCH-LOGICAL-c337t-d74995e990c7e4674d672e6b235e04b2ad3d8c73a49ed9a2999dc6ad1c00a40b3
container_end_page 516
container_issue 4
container_start_page 508
container_title Europace (London, England)
container_volume 12
creator Choi, Jong-Il
Ryu, Kyungmoo
Park, Euljoon
Benser, Michael E
Jang, Jin Kun
Lee, Hyun Soo
Lim, Hong Euy
Pak, Hui-Nam
Kim, Young-Hoon
description Multisite atrial pacing has been suggested to be effective in suppressing atrial fibrillation (AF), however, the effect of linear triple-site atrial pacing (LTSP) in humans has not been evaluated. We compared the effects of LTSP to single-site atrial pacing (SSP) on the atrial activation and wavefront propagation pattern in patients with persistent AF. In 10 patients with persistent AF, the effects of LTSP and SSP were evaluated by left atrial (LA) endocardial non-contact multielectrode array mapping and multipolar catheters. LTSP and SSP were delivered from the high right atrium (HRA), the distal coronary sinus (CS), and within the LA at the site showing maximal overlay of low-voltage zones during sinus rhythm and pacing at HRA and CS. Atrial activation time and pattern, P wave duration, and the prevention of AF induced by burst pacing were assessed with these pacing interventions. Compared with SSP, LTSP at the HRA, CS, and LA shortened atrial activation times (183 +/- 24 vs. 174 +/- 24 ms, 186 +/- 29 vs. 166 +/- 28 ms, and 171 +/- 40 vs. 163 +/- 39 ms; P < 0.05, respectively). P wave duration was shorter with LTSP than SSP at all three sites (141.7 +/- 35.1 vs. 146.9 +/- 38.5 ms, 138.1 +/- 34.6 vs. 145.7 +/- 33.7 ms, and 142.7 +/- 33.4 vs. 151.3 +/- 35.1 ms; P < 0.05, respectively). LTSP initially depolarized a larger area than SSP, and produced more uniform and planar wavefront propagation. LTSP prevented the burst-induction of AF during LA pacing in 3 of 10 patients, while SSP was never successful. In patients with persistent AF, LTSP provided more rapid and uniform activation of the atria compared with SSP, which was associated with prevention of burst-induction of AF in some patients. Further study is required to determine whether LTSP can modify the substrate of chronic AF, leading to frank AF suppression.
doi_str_mv 10.1093/europace/eup407
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733298572</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733298572</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-d74995e990c7e4674d672e6b235e04b2ad3d8c73a49ed9a2999dc6ad1c00a40b3</originalsourceid><addsrcrecordid>eNo9kU9PwzAMxSMEYjA4c0O5cSqkSdvMx2nin4TEBc6Vm7gQ1LUlyYb4FHxlMrZxsh2997OVx9hFLq5zAeqGVn4Y0VBqxkLoA3aSl0pmUoA8TL0AyMpcwoSdhvAhhNASymM2kUKUVQnVCfuZR--w42iiW2N0Q8-jWxLH3vIRYyTf86HlnesJPU_asaMsuEh8Ha55cP3bfsYtKF2THjm2ycoNeuuGNfmwAbt-g3TUx8C_XHzfW1rXeNd1f9vP2FGLXaDzXZ2y17vbl8VD9vR8_7iYP2VGKR0zqwuAkgCE0VRUurCVllQ1UpUkikaiVXZmtMICyAJKALCmQpsbIbAQjZqyqy139MPnikKsly4YSlf0NKxCrZWSMCu1TMqbrdL4IQRPbT16t0T_Xeei3oRQ70OotyEkx-WOvWqWZP_1-19Xv7XsiXk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733298572</pqid></control><display><type>article</type><title>Atrial activation time and pattern of linear triple-site vs. single-site atrial pacing after cardioversion in patients with atrial fibrillation</title><source>Oxford Journals Online</source><source>Oxford Open</source><source>PubMed Central</source><creator>Choi, Jong-Il ; Ryu, Kyungmoo ; Park, Euljoon ; Benser, Michael E ; Jang, Jin Kun ; Lee, Hyun Soo ; Lim, Hong Euy ; Pak, Hui-Nam ; Kim, Young-Hoon</creator><creatorcontrib>Choi, Jong-Il ; Ryu, Kyungmoo ; Park, Euljoon ; Benser, Michael E ; Jang, Jin Kun ; Lee, Hyun Soo ; Lim, Hong Euy ; Pak, Hui-Nam ; Kim, Young-Hoon</creatorcontrib><description>Multisite atrial pacing has been suggested to be effective in suppressing atrial fibrillation (AF), however, the effect of linear triple-site atrial pacing (LTSP) in humans has not been evaluated. We compared the effects of LTSP to single-site atrial pacing (SSP) on the atrial activation and wavefront propagation pattern in patients with persistent AF. In 10 patients with persistent AF, the effects of LTSP and SSP were evaluated by left atrial (LA) endocardial non-contact multielectrode array mapping and multipolar catheters. LTSP and SSP were delivered from the high right atrium (HRA), the distal coronary sinus (CS), and within the LA at the site showing maximal overlay of low-voltage zones during sinus rhythm and pacing at HRA and CS. Atrial activation time and pattern, P wave duration, and the prevention of AF induced by burst pacing were assessed with these pacing interventions. Compared with SSP, LTSP at the HRA, CS, and LA shortened atrial activation times (183 +/- 24 vs. 174 +/- 24 ms, 186 +/- 29 vs. 166 +/- 28 ms, and 171 +/- 40 vs. 163 +/- 39 ms; P &lt; 0.05, respectively). P wave duration was shorter with LTSP than SSP at all three sites (141.7 +/- 35.1 vs. 146.9 +/- 38.5 ms, 138.1 +/- 34.6 vs. 145.7 +/- 33.7 ms, and 142.7 +/- 33.4 vs. 151.3 +/- 35.1 ms; P &lt; 0.05, respectively). LTSP initially depolarized a larger area than SSP, and produced more uniform and planar wavefront propagation. LTSP prevented the burst-induction of AF during LA pacing in 3 of 10 patients, while SSP was never successful. In patients with persistent AF, LTSP provided more rapid and uniform activation of the atria compared with SSP, which was associated with prevention of burst-induction of AF in some patients. Further study is required to determine whether LTSP can modify the substrate of chronic AF, leading to frank AF suppression.</description><identifier>ISSN: 1099-5129</identifier><identifier>EISSN: 1532-2092</identifier><identifier>DOI: 10.1093/europace/eup407</identifier><identifier>PMID: 20056596</identifier><language>eng</language><publisher>England</publisher><subject>Adult ; Aged ; Atrial Fibrillation - physiopathology ; Atrial Fibrillation - prevention &amp; control ; Atrial Fibrillation - therapy ; Cardiac Pacing, Artificial - methods ; Electric Countershock ; Electrodes, Implanted ; Electrophysiologic Techniques, Cardiac ; Female ; Heart Conduction System - physiology ; Humans ; Male ; Middle Aged ; Treatment Outcome</subject><ispartof>Europace (London, England), 2010-04, Vol.12 (4), p.508-516</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c337t-d74995e990c7e4674d672e6b235e04b2ad3d8c73a49ed9a2999dc6ad1c00a40b3</citedby><cites>FETCH-LOGICAL-c337t-d74995e990c7e4674d672e6b235e04b2ad3d8c73a49ed9a2999dc6ad1c00a40b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20056596$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Choi, Jong-Il</creatorcontrib><creatorcontrib>Ryu, Kyungmoo</creatorcontrib><creatorcontrib>Park, Euljoon</creatorcontrib><creatorcontrib>Benser, Michael E</creatorcontrib><creatorcontrib>Jang, Jin Kun</creatorcontrib><creatorcontrib>Lee, Hyun Soo</creatorcontrib><creatorcontrib>Lim, Hong Euy</creatorcontrib><creatorcontrib>Pak, Hui-Nam</creatorcontrib><creatorcontrib>Kim, Young-Hoon</creatorcontrib><title>Atrial activation time and pattern of linear triple-site vs. single-site atrial pacing after cardioversion in patients with atrial fibrillation</title><title>Europace (London, England)</title><addtitle>Europace</addtitle><description>Multisite atrial pacing has been suggested to be effective in suppressing atrial fibrillation (AF), however, the effect of linear triple-site atrial pacing (LTSP) in humans has not been evaluated. We compared the effects of LTSP to single-site atrial pacing (SSP) on the atrial activation and wavefront propagation pattern in patients with persistent AF. In 10 patients with persistent AF, the effects of LTSP and SSP were evaluated by left atrial (LA) endocardial non-contact multielectrode array mapping and multipolar catheters. LTSP and SSP were delivered from the high right atrium (HRA), the distal coronary sinus (CS), and within the LA at the site showing maximal overlay of low-voltage zones during sinus rhythm and pacing at HRA and CS. Atrial activation time and pattern, P wave duration, and the prevention of AF induced by burst pacing were assessed with these pacing interventions. Compared with SSP, LTSP at the HRA, CS, and LA shortened atrial activation times (183 +/- 24 vs. 174 +/- 24 ms, 186 +/- 29 vs. 166 +/- 28 ms, and 171 +/- 40 vs. 163 +/- 39 ms; P &lt; 0.05, respectively). P wave duration was shorter with LTSP than SSP at all three sites (141.7 +/- 35.1 vs. 146.9 +/- 38.5 ms, 138.1 +/- 34.6 vs. 145.7 +/- 33.7 ms, and 142.7 +/- 33.4 vs. 151.3 +/- 35.1 ms; P &lt; 0.05, respectively). LTSP initially depolarized a larger area than SSP, and produced more uniform and planar wavefront propagation. LTSP prevented the burst-induction of AF during LA pacing in 3 of 10 patients, while SSP was never successful. In patients with persistent AF, LTSP provided more rapid and uniform activation of the atria compared with SSP, which was associated with prevention of burst-induction of AF in some patients. Further study is required to determine whether LTSP can modify the substrate of chronic AF, leading to frank AF suppression.</description><subject>Adult</subject><subject>Aged</subject><subject>Atrial Fibrillation - physiopathology</subject><subject>Atrial Fibrillation - prevention &amp; control</subject><subject>Atrial Fibrillation - therapy</subject><subject>Cardiac Pacing, Artificial - methods</subject><subject>Electric Countershock</subject><subject>Electrodes, Implanted</subject><subject>Electrophysiologic Techniques, Cardiac</subject><subject>Female</subject><subject>Heart Conduction System - physiology</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Treatment Outcome</subject><issn>1099-5129</issn><issn>1532-2092</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNo9kU9PwzAMxSMEYjA4c0O5cSqkSdvMx2nin4TEBc6Vm7gQ1LUlyYb4FHxlMrZxsh2997OVx9hFLq5zAeqGVn4Y0VBqxkLoA3aSl0pmUoA8TL0AyMpcwoSdhvAhhNASymM2kUKUVQnVCfuZR--w42iiW2N0Q8-jWxLH3vIRYyTf86HlnesJPU_asaMsuEh8Ha55cP3bfsYtKF2THjm2ycoNeuuGNfmwAbt-g3TUx8C_XHzfW1rXeNd1f9vP2FGLXaDzXZ2y17vbl8VD9vR8_7iYP2VGKR0zqwuAkgCE0VRUurCVllQ1UpUkikaiVXZmtMICyAJKALCmQpsbIbAQjZqyqy139MPnikKsly4YSlf0NKxCrZWSMCu1TMqbrdL4IQRPbT16t0T_Xeei3oRQ70OotyEkx-WOvWqWZP_1-19Xv7XsiXk</recordid><startdate>201004</startdate><enddate>201004</enddate><creator>Choi, Jong-Il</creator><creator>Ryu, Kyungmoo</creator><creator>Park, Euljoon</creator><creator>Benser, Michael E</creator><creator>Jang, Jin Kun</creator><creator>Lee, Hyun Soo</creator><creator>Lim, Hong Euy</creator><creator>Pak, Hui-Nam</creator><creator>Kim, Young-Hoon</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201004</creationdate><title>Atrial activation time and pattern of linear triple-site vs. single-site atrial pacing after cardioversion in patients with atrial fibrillation</title><author>Choi, Jong-Il ; Ryu, Kyungmoo ; Park, Euljoon ; Benser, Michael E ; Jang, Jin Kun ; Lee, Hyun Soo ; Lim, Hong Euy ; Pak, Hui-Nam ; Kim, Young-Hoon</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-d74995e990c7e4674d672e6b235e04b2ad3d8c73a49ed9a2999dc6ad1c00a40b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Atrial Fibrillation - physiopathology</topic><topic>Atrial Fibrillation - prevention &amp; control</topic><topic>Atrial Fibrillation - therapy</topic><topic>Cardiac Pacing, Artificial - methods</topic><topic>Electric Countershock</topic><topic>Electrodes, Implanted</topic><topic>Electrophysiologic Techniques, Cardiac</topic><topic>Female</topic><topic>Heart Conduction System - physiology</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Choi, Jong-Il</creatorcontrib><creatorcontrib>Ryu, Kyungmoo</creatorcontrib><creatorcontrib>Park, Euljoon</creatorcontrib><creatorcontrib>Benser, Michael E</creatorcontrib><creatorcontrib>Jang, Jin Kun</creatorcontrib><creatorcontrib>Lee, Hyun Soo</creatorcontrib><creatorcontrib>Lim, Hong Euy</creatorcontrib><creatorcontrib>Pak, Hui-Nam</creatorcontrib><creatorcontrib>Kim, Young-Hoon</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Europace (London, England)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Choi, Jong-Il</au><au>Ryu, Kyungmoo</au><au>Park, Euljoon</au><au>Benser, Michael E</au><au>Jang, Jin Kun</au><au>Lee, Hyun Soo</au><au>Lim, Hong Euy</au><au>Pak, Hui-Nam</au><au>Kim, Young-Hoon</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Atrial activation time and pattern of linear triple-site vs. single-site atrial pacing after cardioversion in patients with atrial fibrillation</atitle><jtitle>Europace (London, England)</jtitle><addtitle>Europace</addtitle><date>2010-04</date><risdate>2010</risdate><volume>12</volume><issue>4</issue><spage>508</spage><epage>516</epage><pages>508-516</pages><issn>1099-5129</issn><eissn>1532-2092</eissn><abstract>Multisite atrial pacing has been suggested to be effective in suppressing atrial fibrillation (AF), however, the effect of linear triple-site atrial pacing (LTSP) in humans has not been evaluated. We compared the effects of LTSP to single-site atrial pacing (SSP) on the atrial activation and wavefront propagation pattern in patients with persistent AF. In 10 patients with persistent AF, the effects of LTSP and SSP were evaluated by left atrial (LA) endocardial non-contact multielectrode array mapping and multipolar catheters. LTSP and SSP were delivered from the high right atrium (HRA), the distal coronary sinus (CS), and within the LA at the site showing maximal overlay of low-voltage zones during sinus rhythm and pacing at HRA and CS. Atrial activation time and pattern, P wave duration, and the prevention of AF induced by burst pacing were assessed with these pacing interventions. Compared with SSP, LTSP at the HRA, CS, and LA shortened atrial activation times (183 +/- 24 vs. 174 +/- 24 ms, 186 +/- 29 vs. 166 +/- 28 ms, and 171 +/- 40 vs. 163 +/- 39 ms; P &lt; 0.05, respectively). P wave duration was shorter with LTSP than SSP at all three sites (141.7 +/- 35.1 vs. 146.9 +/- 38.5 ms, 138.1 +/- 34.6 vs. 145.7 +/- 33.7 ms, and 142.7 +/- 33.4 vs. 151.3 +/- 35.1 ms; P &lt; 0.05, respectively). LTSP initially depolarized a larger area than SSP, and produced more uniform and planar wavefront propagation. LTSP prevented the burst-induction of AF during LA pacing in 3 of 10 patients, while SSP was never successful. In patients with persistent AF, LTSP provided more rapid and uniform activation of the atria compared with SSP, which was associated with prevention of burst-induction of AF in some patients. Further study is required to determine whether LTSP can modify the substrate of chronic AF, leading to frank AF suppression.</abstract><cop>England</cop><pmid>20056596</pmid><doi>10.1093/europace/eup407</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1099-5129
ispartof Europace (London, England), 2010-04, Vol.12 (4), p.508-516
issn 1099-5129
1532-2092
language eng
recordid cdi_proquest_miscellaneous_733298572
source Oxford Journals Online; Oxford Open; PubMed Central
subjects Adult
Aged
Atrial Fibrillation - physiopathology
Atrial Fibrillation - prevention & control
Atrial Fibrillation - therapy
Cardiac Pacing, Artificial - methods
Electric Countershock
Electrodes, Implanted
Electrophysiologic Techniques, Cardiac
Female
Heart Conduction System - physiology
Humans
Male
Middle Aged
Treatment Outcome
title Atrial activation time and pattern of linear triple-site vs. single-site atrial pacing after cardioversion in patients with atrial fibrillation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T02%3A27%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Atrial%20activation%20time%20and%20pattern%20of%20linear%20triple-site%20vs.%20single-site%20atrial%20pacing%20after%20cardioversion%20in%20patients%20with%20atrial%20fibrillation&rft.jtitle=Europace%20(London,%20England)&rft.au=Choi,%20Jong-Il&rft.date=2010-04&rft.volume=12&rft.issue=4&rft.spage=508&rft.epage=516&rft.pages=508-516&rft.issn=1099-5129&rft.eissn=1532-2092&rft_id=info:doi/10.1093/europace/eup407&rft_dat=%3Cproquest_cross%3E733298572%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c337t-d74995e990c7e4674d672e6b235e04b2ad3d8c73a49ed9a2999dc6ad1c00a40b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=733298572&rft_id=info:pmid/20056596&rfr_iscdi=true