Left ventricular ejection fraction and volumes as measured by 3d echocardiography and ultrafast computed tomography

Real-time three-dimensional echocardiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. Thirty nine consecutive patients (27 men...

Full description

Saved in:
Bibliographic Details
Published in:Arquivos brasileiros de cardiologia 2009-04, Vol.92 (4), p.294-301
Main Authors: Vieira, Marcelo Luiz Campos, Nomura, César H, Tranchesi Junior, Bernardino, Oliveira, Wercules A de, Naccarato, Gustavo, Serpa, Bruna S, Passos, Rodrigo B D, Funari, Marcelo B G, Fischer, Cláudio H, Morhy, Samira S
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Real-time three-dimensional echocardiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. Thirty nine consecutive patients (27 men, mean age of 57+/-12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT. LVEF and LV volumes were analyzed. coefficient of correlation (r: Pearson), Bland-Altman analysis, linear regression analysis, 95% CI, p