Loading…

Effective environmental sampling strategies for monitoring Legionella spp contamination in hot water systems

Background The prevention and control of legionellosis in hospital settings involves environmental sampling, among other measures. The data yielded by sampling constitute an important means of risk assessment and provide a valid basis on which to plan remedial (cleansing and disinfection) and preven...

Full description

Saved in:
Bibliographic Details
Published in:American journal of infection control 2010-06, Vol.38 (5), p.344-349
Main Authors: Ditommaso, Savina, DBiol, Giacomuzzi, Monica, BSc, Gentile, Marino, BSc, Moiraghi, Angela Ruggenini, MD, Zotti, Carla M., DBiol
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background The prevention and control of legionellosis in hospital settings involves environmental sampling, among other measures. The data yielded by sampling constitute an important means of risk assessment and provide a valid basis on which to plan remedial (cleansing and disinfection) and preventive (maintenance) interventions. This retrospective study had 2 objectives: (1) to evaluate the utility of biofilm sampling at distal sites and (2) to identify an efficient environmental sampling strategy. Methods Samples of hot water and biofilm were collected between June 1999 and March 2008 from 41 hospitals in Italy's Piemonte region. We analyzed results of the samples (water and biofilm) taken from the same site and results of the water samples taken from the recirculation loop and water samples taken from the distal sites during the same sampling run. Results Microbiological analysis was performed on 3910 pairs of samples (water/biofilm). In 81% of the pairs, the results were concordant; in 17% of the pairs, Legionella was isolated only from the water samples, and in only 2% of the pairs was Legionella isolated from the biofilm sample alone. Data from 299 sampling runs show that 79% (236) of results from the water samples taken from the recirculation loop and water samples taken from the distal sites during the same sampling run were concordant, and 21% (63) were discordant. Conclusions Our findings suggest that hospitals could safely adopt a simpler (water sampling only without biofilm sampling) and more efficient (monitoring of the entire system through sampling of recirculation loop water) environmental sampling policy.
ISSN:0196-6553
1527-3296