Loading…

Use of elbow dynasplint for reduction of elbow flexion contractures: a case study

A severe elbow flexion contracture following a supracondylar fracture in a 13-yearold- male was treated with conventional physical therapy and an adjustable dynamic splint, the elbow Dynasplint(R). The Dynasplint was applied primarily at night. The patient achieved complete resolution of his flexion...

Full description

Saved in:
Bibliographic Details
Published in:The journal of orthopaedic and sports physical therapy 1984, Vol.5 (5), p.269-274
Main Authors: Hepburn, G R, Crivelli, K J
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A severe elbow flexion contracture following a supracondylar fracture in a 13-yearold- male was treated with conventional physical therapy and an adjustable dynamic splint, the elbow Dynasplint(R). The Dynasplint was applied primarily at night. The patient achieved complete resolution of his flexion contracture. The Dynasplint incorporates the principles of adjustable, low-intensity force for prolonged durations of time.J Orthop Sports Phys Ther 1984;5(5):269-274.
ISSN:0190-6011
1938-1344
DOI:10.2519/jospt.1984.5.5.269