An analytical study of the vanadium(IV)-chromium(VI) reaction

Experimental conditions for reduction of chromium(VI) by vanadiuin(IV) are described. An excess of vanadium(IV) is necessary. The evidence indicates that the direct titration fails for kinetic rather than thermodynamic reasons, but that the back-titration procedure is made quantitative by the slow r...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) 1971-03, Vol.18 (3), p.361-364
Main Author: Sriramam, K.
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Experimental conditions for reduction of chromium(VI) by vanadiuin(IV) are described. An excess of vanadium(IV) is necessary. The evidence indicates that the direct titration fails for kinetic rather than thermodynamic reasons, but that the back-titration procedure is made quantitative by the slow rate of the reverse reaction between vanadium(V) and chromium(III). Die Versuchsbedingungen zur Reduktion von Chrom(VI) mit Vanadium(IV) werden beschrieben. Ein Überschuß von Vanadium(IV) ist notwendig. Die Ergebnisse zeigen, daß die Titration eher aus kinetischen als aus thennodynamischen Gründen fehlschlägt; das Rücktitrationsverfahren geht jedoch quantitativ, da die Rückreaktion zwischen Vanadium(V) und Chrom(III) langsam verläuft. On décrit les conditions expérimentales pour la réduction du chrome(VI) par le vanadium(IV). Un excès de vanadium(IV) est nécessaire. L'expérience montre que le titrage direct ne marche pas pour des raisons cinétiques, plutôt que thermodynamiques mais que la technique de titrage en retour est rendue quantitative par la faible vitesse de la réaction inverse entre vanadium(V) et chrome(III).
ISSN:0039-9140
1873-3573
DOI:10.1016/0039-9140(71)80051-6