Polycrystalline and monocrystalline antimony, iridium and palladium as electrode material for pH-sensing electrodes

Different ways of making pH-sensing electrodes from monocrystalline or polycrystalline antimony, iridium and palladium have been investigated. Monocrystalline antimony and iridium are superior to the polycrystalline elements with respect to reproducibility between electrodes and stability of the ele...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) 1986-02, Vol.33 (2), p.125-134
Main Authors: Kinoshita, Eita, Ingman, Folke, Edwall, Gunnar, Thulin, Sigvard, Gła̧b, Stanisław
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c359t-ba057a2868e9800291450dd464f37d75f56c83460c61e62ed0b4fbbabce0d5583
cites
container_end_page 134
container_issue 2
container_start_page 125
container_title Talanta (Oxford)
container_volume 33
creator Kinoshita, Eita
Ingman, Folke
Edwall, Gunnar
Thulin, Sigvard
Gła̧b, Stanisław
description Different ways of making pH-sensing electrodes from monocrystalline or polycrystalline antimony, iridium and palladium have been investigated. Monocrystalline antimony and iridium are superior to the polycrystalline elements with respect to reproducibility between electrodes and stability of the electrode potential over long periods of time. No good palladium/palladium oxide electrode could be obtained by electrochemical oxidation and the thermal preparation method could not take advantage of the properties of the monocrystalline palladium. Therefore, only polycrystalline palladium was used to study this type of electrodes. The different electrodes were compared with respect to the manner of preparation, the pH-response (reproducibility and time response) and the effect that different complexing ligands present in the measuring solutions may have on the electrode response. Also, the redox-response of the electrodes and the effect of different oxygen pressures on the electrode potentials were studied. The monocrystalline antimony electrodes have the best reproducibility and long-term stability but also respond to complexing ligands and to variations in the oxygen pressure. Monocrystalline iridium electrodes can be obtained by continuously cycling the potential between −0.25 and +1.25 V (SCE) in 0.5 M sulphuric acid. They do not respond to the complexing ligands tested, and have fairly good long-term stability, but the reproducibility between electrodes is inferior to that of the monocrystalline antimony electrodes. Polycrystalline antimony and iridium electrodes were inferior to the monocrystalline ones. The properties of the palladium electrodes were similar to those of the iridium ones.
doi_str_mv 10.1016/0039-9140(86)80028-5
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733823720</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0039914086800285</els_id><sourcerecordid>733823720</sourcerecordid><originalsourceid>FETCH-LOGICAL-c359t-ba057a2868e9800291450dd464f37d75f56c83460c61e62ed0b4fbbabce0d5583</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMo7rr6D0R6U8HqtGnS9CLI4hcs6EHPIU2mEmmbNekK--_NfuDixVPI5JnMvA8hpxlcZ5DxGwBapVVWwIXglwIgFynbI-NMlDSlrKT7ZPyLjMhRCJ8QIQr0kIwyUfECCjEm4dW1S-2XYVBta3tMVG-SzvXub22wsba8Sqy3xi66NTWPr2pzCwm2qAfvDCadGtBb1SaN88n8KQ3YB9t_7IhwTA4a1QY82Z4T8v5w_zZ9Smcvj8_Tu1mqKauGtFbASpULLrBa5YtBGBhT8KKhpSlZw7gWtOCgeYY8RwN10dS1qjWCYUzQCTnf_Dv37muBYZCdDRrj1j26RZAlpSKnZQ6RLDak9i4Ej42ce9spv5QZyJVtuVIpVyql4HJtW7LYdrYdsKg7NLumrd4I3G4AjDG_LXoZtMVeo7E-2pDG2f8n_AAMUJCn</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733823720</pqid></control><display><type>article</type><title>Polycrystalline and monocrystalline antimony, iridium and palladium as electrode material for pH-sensing electrodes</title><source>ScienceDirect Physical &amp; Analytical Chemistry Backfile</source><creator>Kinoshita, Eita ; Ingman, Folke ; Edwall, Gunnar ; Thulin, Sigvard ; Gła̧b, Stanisław</creator><creatorcontrib>Kinoshita, Eita ; Ingman, Folke ; Edwall, Gunnar ; Thulin, Sigvard ; Gła̧b, Stanisław</creatorcontrib><description>Different ways of making pH-sensing electrodes from monocrystalline or polycrystalline antimony, iridium and palladium have been investigated. Monocrystalline antimony and iridium are superior to the polycrystalline elements with respect to reproducibility between electrodes and stability of the electrode potential over long periods of time. No good palladium/palladium oxide electrode could be obtained by electrochemical oxidation and the thermal preparation method could not take advantage of the properties of the monocrystalline palladium. Therefore, only polycrystalline palladium was used to study this type of electrodes. The different electrodes were compared with respect to the manner of preparation, the pH-response (reproducibility and time response) and the effect that different complexing ligands present in the measuring solutions may have on the electrode response. Also, the redox-response of the electrodes and the effect of different oxygen pressures on the electrode potentials were studied. The monocrystalline antimony electrodes have the best reproducibility and long-term stability but also respond to complexing ligands and to variations in the oxygen pressure. Monocrystalline iridium electrodes can be obtained by continuously cycling the potential between −0.25 and +1.25 V (SCE) in 0.5 M sulphuric acid. They do not respond to the complexing ligands tested, and have fairly good long-term stability, but the reproducibility between electrodes is inferior to that of the monocrystalline antimony electrodes. Polycrystalline antimony and iridium electrodes were inferior to the monocrystalline ones. The properties of the palladium electrodes were similar to those of the iridium ones.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/0039-9140(86)80028-5</identifier><identifier>PMID: 18964048</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><ispartof>Talanta (Oxford), 1986-02, Vol.33 (2), p.125-134</ispartof><rights>1986</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c359t-ba057a2868e9800291450dd464f37d75f56c83460c61e62ed0b4fbbabce0d5583</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0039914086800285$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3606,27898,27899,45956</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18964048$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kinoshita, Eita</creatorcontrib><creatorcontrib>Ingman, Folke</creatorcontrib><creatorcontrib>Edwall, Gunnar</creatorcontrib><creatorcontrib>Thulin, Sigvard</creatorcontrib><creatorcontrib>Gła̧b, Stanisław</creatorcontrib><title>Polycrystalline and monocrystalline antimony, iridium and palladium as electrode material for pH-sensing electrodes</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Different ways of making pH-sensing electrodes from monocrystalline or polycrystalline antimony, iridium and palladium have been investigated. Monocrystalline antimony and iridium are superior to the polycrystalline elements with respect to reproducibility between electrodes and stability of the electrode potential over long periods of time. No good palladium/palladium oxide electrode could be obtained by electrochemical oxidation and the thermal preparation method could not take advantage of the properties of the monocrystalline palladium. Therefore, only polycrystalline palladium was used to study this type of electrodes. The different electrodes were compared with respect to the manner of preparation, the pH-response (reproducibility and time response) and the effect that different complexing ligands present in the measuring solutions may have on the electrode response. Also, the redox-response of the electrodes and the effect of different oxygen pressures on the electrode potentials were studied. The monocrystalline antimony electrodes have the best reproducibility and long-term stability but also respond to complexing ligands and to variations in the oxygen pressure. Monocrystalline iridium electrodes can be obtained by continuously cycling the potential between −0.25 and +1.25 V (SCE) in 0.5 M sulphuric acid. They do not respond to the complexing ligands tested, and have fairly good long-term stability, but the reproducibility between electrodes is inferior to that of the monocrystalline antimony electrodes. Polycrystalline antimony and iridium electrodes were inferior to the monocrystalline ones. The properties of the palladium electrodes were similar to those of the iridium ones.</description><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1986</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhoMo7rr6D0R6U8HqtGnS9CLI4hcs6EHPIU2mEmmbNekK--_NfuDixVPI5JnMvA8hpxlcZ5DxGwBapVVWwIXglwIgFynbI-NMlDSlrKT7ZPyLjMhRCJ8QIQr0kIwyUfECCjEm4dW1S-2XYVBta3tMVG-SzvXub22wsba8Sqy3xi66NTWPr2pzCwm2qAfvDCadGtBb1SaN88n8KQ3YB9t_7IhwTA4a1QY82Z4T8v5w_zZ9Smcvj8_Tu1mqKauGtFbASpULLrBa5YtBGBhT8KKhpSlZw7gWtOCgeYY8RwN10dS1qjWCYUzQCTnf_Dv37muBYZCdDRrj1j26RZAlpSKnZQ6RLDak9i4Ej42ce9spv5QZyJVtuVIpVyql4HJtW7LYdrYdsKg7NLumrd4I3G4AjDG_LXoZtMVeo7E-2pDG2f8n_AAMUJCn</recordid><startdate>19860201</startdate><enddate>19860201</enddate><creator>Kinoshita, Eita</creator><creator>Ingman, Folke</creator><creator>Edwall, Gunnar</creator><creator>Thulin, Sigvard</creator><creator>Gła̧b, Stanisław</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19860201</creationdate><title>Polycrystalline and monocrystalline antimony, iridium and palladium as electrode material for pH-sensing electrodes</title><author>Kinoshita, Eita ; Ingman, Folke ; Edwall, Gunnar ; Thulin, Sigvard ; Gła̧b, Stanisław</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c359t-ba057a2868e9800291450dd464f37d75f56c83460c61e62ed0b4fbbabce0d5583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1986</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kinoshita, Eita</creatorcontrib><creatorcontrib>Ingman, Folke</creatorcontrib><creatorcontrib>Edwall, Gunnar</creatorcontrib><creatorcontrib>Thulin, Sigvard</creatorcontrib><creatorcontrib>Gła̧b, Stanisław</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kinoshita, Eita</au><au>Ingman, Folke</au><au>Edwall, Gunnar</au><au>Thulin, Sigvard</au><au>Gła̧b, Stanisław</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Polycrystalline and monocrystalline antimony, iridium and palladium as electrode material for pH-sensing electrodes</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>1986-02-01</date><risdate>1986</risdate><volume>33</volume><issue>2</issue><spage>125</spage><epage>134</epage><pages>125-134</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>Different ways of making pH-sensing electrodes from monocrystalline or polycrystalline antimony, iridium and palladium have been investigated. Monocrystalline antimony and iridium are superior to the polycrystalline elements with respect to reproducibility between electrodes and stability of the electrode potential over long periods of time. No good palladium/palladium oxide electrode could be obtained by electrochemical oxidation and the thermal preparation method could not take advantage of the properties of the monocrystalline palladium. Therefore, only polycrystalline palladium was used to study this type of electrodes. The different electrodes were compared with respect to the manner of preparation, the pH-response (reproducibility and time response) and the effect that different complexing ligands present in the measuring solutions may have on the electrode response. Also, the redox-response of the electrodes and the effect of different oxygen pressures on the electrode potentials were studied. The monocrystalline antimony electrodes have the best reproducibility and long-term stability but also respond to complexing ligands and to variations in the oxygen pressure. Monocrystalline iridium electrodes can be obtained by continuously cycling the potential between −0.25 and +1.25 V (SCE) in 0.5 M sulphuric acid. They do not respond to the complexing ligands tested, and have fairly good long-term stability, but the reproducibility between electrodes is inferior to that of the monocrystalline antimony electrodes. Polycrystalline antimony and iridium electrodes were inferior to the monocrystalline ones. The properties of the palladium electrodes were similar to those of the iridium ones.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>18964048</pmid><doi>10.1016/0039-9140(86)80028-5</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 1986-02, Vol.33 (2), p.125-134
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733823720
source ScienceDirect Physical & Analytical Chemistry Backfile
title Polycrystalline and monocrystalline antimony, iridium and palladium as electrode material for pH-sensing electrodes
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-03-05T19%3A08%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Polycrystalline%20and%20monocrystalline%20antimony,%20iridium%20and%20palladium%20as%20electrode%20material%20for%20pH-sensing%20electrodes&rft.jtitle=Talanta%20(Oxford)&rft.au=Kinoshita,%20Eita&rft.date=1986-02-01&rft.volume=33&rft.issue=2&rft.spage=125&rft.epage=134&rft.pages=125-134&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/0039-9140(86)80028-5&rft_dat=%3Cproquest_cross%3E733823720%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c359t-ba057a2868e9800291450dd464f37d75f56c83460c61e62ed0b4fbbabce0d5583%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=733823720&rft_id=info:pmid/18964048&rfr_iscdi=true