Determination of arsenic in polluted waters by differential pulse anodic-stripping voltammetry

Experimental parameters affecting the analytical response of arsenic in differential pulse anodic-stripping voltammetry (DPASV) have been examined. DPASV offers higher sensitivity than linear-scan anodic-stripping voltammetry for similar analysis times. Both techniques have been applied to the NBS S...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) 1982-06, Vol.29 (6), p.515-518
Main Authors: Leung, P.C., Subramanian, K.S., Méranger, J.C.
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c421t-4ceef6ad179292bca14fd3957ce2b2b6f9de2450b98726763c209d2cb284a4a03
cites
container_end_page 518
container_issue 6
container_start_page 515
container_title Talanta (Oxford)
container_volume 29
creator Leung, P.C.
Subramanian, K.S.
Méranger, J.C.
description Experimental parameters affecting the analytical response of arsenic in differential pulse anodic-stripping voltammetry (DPASV) have been examined. DPASV offers higher sensitivity than linear-scan anodic-stripping voltammetry for similar analysis times. Both techniques have been applied to the NBS Standard Reference Water (SRM 1643) and some polluted water samples. The results on polluted waters compared favourably with those obtained by graphite-furnace atomic-absorption spectroscopy.
doi_str_mv 10.1016/0039-9140(82)80205-1
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733826515</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0039914082802051</els_id><sourcerecordid>733826515</sourcerecordid><originalsourceid>FETCH-LOGICAL-c421t-4ceef6ad179292bca14fd3957ce2b2b6f9de2450b98726763c209d2cb284a4a03</originalsourceid><addsrcrecordid>eNqF0UuL1TAch-EginMc_QYiWXlZVHNrLhtBxisMuNGtIU3-lUib1CQdOd_e1nPQ3bjK5skvkBehx5S8pITKV4Rw0xkqyHPNXmjCSN_RO-hAteId7xW_iw5_yQV6UOsPQgjjhN9HF1QbyamSB_TtLTQoc0yuxZxwHrErFVL0OCa85GlaGwT8y22o4uGIQxxHKJBadBNe1qkCdimH6LvaSlyWmL7jmzw1N8_QyvEhuje6DT06n5fo6_t3X64-dtefP3y6enPdecFo64QHGKULVBlm2OAdFWPgplce2MAGOZoATPRkMFoxqST3jJjA_MC0cMIRfomenXaXkn-uUJudY_UwTS5BXqtVnGsme9pv8umtknGujBL0v5BybYiR-6I4QV9yrQVGu5Q4u3K0lNg9ld072L2D1cz-SWX3_Sfn_XWYIfy7dG6zgdcnANvH3UQotvoIyUOIBXyzIcfbX_gNYzSjyw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13890965</pqid></control><display><type>article</type><title>Determination of arsenic in polluted waters by differential pulse anodic-stripping voltammetry</title><source>ScienceDirect Physical &amp; Analytical Chemistry Backfile</source><creator>Leung, P.C. ; Subramanian, K.S. ; Méranger, J.C.</creator><creatorcontrib>Leung, P.C. ; Subramanian, K.S. ; Méranger, J.C.</creatorcontrib><description>Experimental parameters affecting the analytical response of arsenic in differential pulse anodic-stripping voltammetry (DPASV) have been examined. DPASV offers higher sensitivity than linear-scan anodic-stripping voltammetry for similar analysis times. Both techniques have been applied to the NBS Standard Reference Water (SRM 1643) and some polluted water samples. The results on polluted waters compared favourably with those obtained by graphite-furnace atomic-absorption spectroscopy.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/0039-9140(82)80205-1</identifier><identifier>PMID: 18963176</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><ispartof>Talanta (Oxford), 1982-06, Vol.29 (6), p.515-518</ispartof><rights>1982</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c421t-4ceef6ad179292bca14fd3957ce2b2b6f9de2450b98726763c209d2cb284a4a03</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0039914082802051$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3618,27923,27924,45982</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18963176$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Leung, P.C.</creatorcontrib><creatorcontrib>Subramanian, K.S.</creatorcontrib><creatorcontrib>Méranger, J.C.</creatorcontrib><title>Determination of arsenic in polluted waters by differential pulse anodic-stripping voltammetry</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Experimental parameters affecting the analytical response of arsenic in differential pulse anodic-stripping voltammetry (DPASV) have been examined. DPASV offers higher sensitivity than linear-scan anodic-stripping voltammetry for similar analysis times. Both techniques have been applied to the NBS Standard Reference Water (SRM 1643) and some polluted water samples. The results on polluted waters compared favourably with those obtained by graphite-furnace atomic-absorption spectroscopy.</description><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1982</creationdate><recordtype>article</recordtype><recordid>eNqF0UuL1TAch-EginMc_QYiWXlZVHNrLhtBxisMuNGtIU3-lUib1CQdOd_e1nPQ3bjK5skvkBehx5S8pITKV4Rw0xkqyHPNXmjCSN_RO-hAteId7xW_iw5_yQV6UOsPQgjjhN9HF1QbyamSB_TtLTQoc0yuxZxwHrErFVL0OCa85GlaGwT8y22o4uGIQxxHKJBadBNe1qkCdimH6LvaSlyWmL7jmzw1N8_QyvEhuje6DT06n5fo6_t3X64-dtefP3y6enPdecFo64QHGKULVBlm2OAdFWPgplce2MAGOZoATPRkMFoxqST3jJjA_MC0cMIRfomenXaXkn-uUJudY_UwTS5BXqtVnGsme9pv8umtknGujBL0v5BybYiR-6I4QV9yrQVGu5Q4u3K0lNg9ld072L2D1cz-SWX3_Sfn_XWYIfy7dG6zgdcnANvH3UQotvoIyUOIBXyzIcfbX_gNYzSjyw</recordid><startdate>198206</startdate><enddate>198206</enddate><creator>Leung, P.C.</creator><creator>Subramanian, K.S.</creator><creator>Méranger, J.C.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>7X8</scope></search><sort><creationdate>198206</creationdate><title>Determination of arsenic in polluted waters by differential pulse anodic-stripping voltammetry</title><author>Leung, P.C. ; Subramanian, K.S. ; Méranger, J.C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c421t-4ceef6ad179292bca14fd3957ce2b2b6f9de2450b98726763c209d2cb284a4a03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1982</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Leung, P.C.</creatorcontrib><creatorcontrib>Subramanian, K.S.</creatorcontrib><creatorcontrib>Méranger, J.C.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Leung, P.C.</au><au>Subramanian, K.S.</au><au>Méranger, J.C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of arsenic in polluted waters by differential pulse anodic-stripping voltammetry</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>1982-06</date><risdate>1982</risdate><volume>29</volume><issue>6</issue><spage>515</spage><epage>518</epage><pages>515-518</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>Experimental parameters affecting the analytical response of arsenic in differential pulse anodic-stripping voltammetry (DPASV) have been examined. DPASV offers higher sensitivity than linear-scan anodic-stripping voltammetry for similar analysis times. Both techniques have been applied to the NBS Standard Reference Water (SRM 1643) and some polluted water samples. The results on polluted waters compared favourably with those obtained by graphite-furnace atomic-absorption spectroscopy.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>18963176</pmid><doi>10.1016/0039-9140(82)80205-1</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 1982-06, Vol.29 (6), p.515-518
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733826515
source ScienceDirect Physical & Analytical Chemistry Backfile
title Determination of arsenic in polluted waters by differential pulse anodic-stripping voltammetry
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T04%3A15%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20arsenic%20in%20polluted%20waters%20by%20differential%20pulse%20anodic-stripping%20voltammetry&rft.jtitle=Talanta%20(Oxford)&rft.au=Leung,%20P.C.&rft.date=1982-06&rft.volume=29&rft.issue=6&rft.spage=515&rft.epage=518&rft.pages=515-518&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/0039-9140(82)80205-1&rft_dat=%3Cproquest_cross%3E733826515%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c421t-4ceef6ad179292bca14fd3957ce2b2b6f9de2450b98726763c209d2cb284a4a03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=13890965&rft_id=info:pmid/18963176&rfr_iscdi=true