Loading…

Uranyl-selective PVC membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides

Four different recently synthesized macrocyclic diamides were studied to characterize their abilities as uranyl ion carriers in PVC membrane electrodes. The electrodes based on macrocycle 1,18-diaza-3,4;15,16-dibenzo-5,8,11,14,21,24-hexaoxacyclohexaeicosane-2,17-dione resulted in a Nernstian respons...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) 2002-08, Vol.58 (2), p.237-246
Main Authors: Shamsipur, Mojtaba, Soleymanpour, Ahmad, Akhond, Morteza, Sharghi, Hashem, Massah, Ahmad Reza
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c392t-bf5aeebbf8782c93ec459f3bf0ad86795882e10c66b477082107286c58c534a43
cites
container_end_page 246
container_issue 2
container_start_page 237
container_title Talanta (Oxford)
container_volume 58
creator Shamsipur, Mojtaba
Soleymanpour, Ahmad
Akhond, Morteza
Sharghi, Hashem
Massah, Ahmad Reza
description Four different recently synthesized macrocyclic diamides were studied to characterize their abilities as uranyl ion carriers in PVC membrane electrodes. The electrodes based on macrocycle 1,18-diaza-3,4;15,16-dibenzo-5,8,11,14,21,24-hexaoxacyclohexaeicosane-2,17-dione resulted in a Nernstian response for UO 2 2+ ion over wide concentration ranges. The linear concentration range for the polymeric membrane electrode (PME) is 3.0×10 −6–8.2×10 −3 M with a detection limit of 2.2×10 −6 and that for the coated graphite electrode (CGE) is 5.0×10 −7–1.5×10 −3 M with a detection limit of 3.5×10 −7 M. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations.
doi_str_mv 10.1016/S0039-9140(02)00238-2
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733828012</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914002002382</els_id><sourcerecordid>733828012</sourcerecordid><originalsourceid>FETCH-LOGICAL-c392t-bf5aeebbf8782c93ec459f3bf0ad86795882e10c66b477082107286c58c534a43</originalsourceid><addsrcrecordid>eNqFkEtLHjEUhoO06Kf2J1iyKbaLaXOZmWRWIh-1FoQK1W5DkjmDKXOxORlh_PXmu1CXrgJvnnPy5iHkjLOvnPH622_GZFM0vGSfmfjCmJC6EAdkxbWShayUfEdW_5Ejcoz4l20oJg_JEddNrVWpViTeRzsufYHQg0_hCejtnzUdYHA5B7pN49QCUmcRWjqNFKcBaAQPY-oXisuYHgDDc750MD5PBc4OU0hzyslgfZz84vvgaRvsEPKmU_K-sz3Ch_15Qu6vvt-tr4ubXz9-ri9vCi8bkQrXVRbAuU4rLXwjwZdV00nXMdvqWjWV1gI483XtSqWYFpwpoWtfaV_J0pbyhJzv9j7G6d8MmMwQ0EPf549NMxolpRaacZHJakfmsogROvMYw2DjYjgzG9tma9tsVBomzNa22cx93L8wuwHa16m93gx82gMWve277NQHfOWkLnPXJnMXOw6yj6cA0aAPMHpoQxadTDuFN6q8ANVfncE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733828012</pqid></control><display><type>article</type><title>Uranyl-selective PVC membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides</title><source>Elsevier</source><creator>Shamsipur, Mojtaba ; Soleymanpour, Ahmad ; Akhond, Morteza ; Sharghi, Hashem ; Massah, Ahmad Reza</creator><creatorcontrib>Shamsipur, Mojtaba ; Soleymanpour, Ahmad ; Akhond, Morteza ; Sharghi, Hashem ; Massah, Ahmad Reza</creatorcontrib><description>Four different recently synthesized macrocyclic diamides were studied to characterize their abilities as uranyl ion carriers in PVC membrane electrodes. The electrodes based on macrocycle 1,18-diaza-3,4;15,16-dibenzo-5,8,11,14,21,24-hexaoxacyclohexaeicosane-2,17-dione resulted in a Nernstian response for UO 2 2+ ion over wide concentration ranges. The linear concentration range for the polymeric membrane electrode (PME) is 3.0×10 −6–8.2×10 −3 M with a detection limit of 2.2×10 −6 and that for the coated graphite electrode (CGE) is 5.0×10 −7–1.5×10 −3 M with a detection limit of 3.5×10 −7 M. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/S0039-9140(02)00238-2</identifier><identifier>PMID: 18968747</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Electrochemical methods ; Exact sciences and technology ; Macrocyclic diamides ; Potentiometry ; PVC membrane ; Uranyl ion-selective electrodes</subject><ispartof>Talanta (Oxford), 2002-08, Vol.58 (2), p.237-246</ispartof><rights>2002 Elsevier Science B.V.</rights><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c392t-bf5aeebbf8782c93ec459f3bf0ad86795882e10c66b477082107286c58c534a43</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13845349$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18968747$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shamsipur, Mojtaba</creatorcontrib><creatorcontrib>Soleymanpour, Ahmad</creatorcontrib><creatorcontrib>Akhond, Morteza</creatorcontrib><creatorcontrib>Sharghi, Hashem</creatorcontrib><creatorcontrib>Massah, Ahmad Reza</creatorcontrib><title>Uranyl-selective PVC membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Four different recently synthesized macrocyclic diamides were studied to characterize their abilities as uranyl ion carriers in PVC membrane electrodes. The electrodes based on macrocycle 1,18-diaza-3,4;15,16-dibenzo-5,8,11,14,21,24-hexaoxacyclohexaeicosane-2,17-dione resulted in a Nernstian response for UO 2 2+ ion over wide concentration ranges. The linear concentration range for the polymeric membrane electrode (PME) is 3.0×10 −6–8.2×10 −3 M with a detection limit of 2.2×10 −6 and that for the coated graphite electrode (CGE) is 5.0×10 −7–1.5×10 −3 M with a detection limit of 3.5×10 −7 M. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Electrochemical methods</subject><subject>Exact sciences and technology</subject><subject>Macrocyclic diamides</subject><subject>Potentiometry</subject><subject>PVC membrane</subject><subject>Uranyl ion-selective electrodes</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLHjEUhoO06Kf2J1iyKbaLaXOZmWRWIh-1FoQK1W5DkjmDKXOxORlh_PXmu1CXrgJvnnPy5iHkjLOvnPH622_GZFM0vGSfmfjCmJC6EAdkxbWShayUfEdW_5Ejcoz4l20oJg_JEddNrVWpViTeRzsufYHQg0_hCejtnzUdYHA5B7pN49QCUmcRWjqNFKcBaAQPY-oXisuYHgDDc750MD5PBc4OU0hzyslgfZz84vvgaRvsEPKmU_K-sz3Ch_15Qu6vvt-tr4ubXz9-ri9vCi8bkQrXVRbAuU4rLXwjwZdV00nXMdvqWjWV1gI483XtSqWYFpwpoWtfaV_J0pbyhJzv9j7G6d8MmMwQ0EPf549NMxolpRaacZHJakfmsogROvMYw2DjYjgzG9tma9tsVBomzNa22cx93L8wuwHa16m93gx82gMWve277NQHfOWkLnPXJnMXOw6yj6cA0aAPMHpoQxadTDuFN6q8ANVfncE</recordid><startdate>20020823</startdate><enddate>20020823</enddate><creator>Shamsipur, Mojtaba</creator><creator>Soleymanpour, Ahmad</creator><creator>Akhond, Morteza</creator><creator>Sharghi, Hashem</creator><creator>Massah, Ahmad Reza</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20020823</creationdate><title>Uranyl-selective PVC membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides</title><author>Shamsipur, Mojtaba ; Soleymanpour, Ahmad ; Akhond, Morteza ; Sharghi, Hashem ; Massah, Ahmad Reza</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c392t-bf5aeebbf8782c93ec459f3bf0ad86795882e10c66b477082107286c58c534a43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Electrochemical methods</topic><topic>Exact sciences and technology</topic><topic>Macrocyclic diamides</topic><topic>Potentiometry</topic><topic>PVC membrane</topic><topic>Uranyl ion-selective electrodes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shamsipur, Mojtaba</creatorcontrib><creatorcontrib>Soleymanpour, Ahmad</creatorcontrib><creatorcontrib>Akhond, Morteza</creatorcontrib><creatorcontrib>Sharghi, Hashem</creatorcontrib><creatorcontrib>Massah, Ahmad Reza</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shamsipur, Mojtaba</au><au>Soleymanpour, Ahmad</au><au>Akhond, Morteza</au><au>Sharghi, Hashem</au><au>Massah, Ahmad Reza</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Uranyl-selective PVC membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2002-08-23</date><risdate>2002</risdate><volume>58</volume><issue>2</issue><spage>237</spage><epage>246</epage><pages>237-246</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>Four different recently synthesized macrocyclic diamides were studied to characterize their abilities as uranyl ion carriers in PVC membrane electrodes. The electrodes based on macrocycle 1,18-diaza-3,4;15,16-dibenzo-5,8,11,14,21,24-hexaoxacyclohexaeicosane-2,17-dione resulted in a Nernstian response for UO 2 2+ ion over wide concentration ranges. The linear concentration range for the polymeric membrane electrode (PME) is 3.0×10 −6–8.2×10 −3 M with a detection limit of 2.2×10 −6 and that for the coated graphite electrode (CGE) is 5.0×10 −7–1.5×10 −3 M with a detection limit of 3.5×10 −7 M. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations.</abstract><cop>Amsterdam</cop><cop>Oxford</cop><pub>Elsevier B.V</pub><pmid>18968747</pmid><doi>10.1016/S0039-9140(02)00238-2</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2002-08, Vol.58 (2), p.237-246
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733828012
source Elsevier
subjects Analytical chemistry
Chemistry
Electrochemical methods
Exact sciences and technology
Macrocyclic diamides
Potentiometry
PVC membrane
Uranyl ion-selective electrodes
title Uranyl-selective PVC membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T17%3A47%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Uranyl-selective%20PVC%20membrane%20electrodes%20based%20on%20some%20recently%20synthesized%20benzo-substituted%20macrocyclic%20diamides&rft.jtitle=Talanta%20(Oxford)&rft.au=Shamsipur,%20Mojtaba&rft.date=2002-08-23&rft.volume=58&rft.issue=2&rft.spage=237&rft.epage=246&rft.pages=237-246&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/S0039-9140(02)00238-2&rft_dat=%3Cproquest_cross%3E733828012%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c392t-bf5aeebbf8782c93ec459f3bf0ad86795882e10c66b477082107286c58c534a43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=733828012&rft_id=info:pmid/18968747&rfr_iscdi=true