Loading…

Rapid and sensitive handheld biosensor for detection of hantavirus antibodies in wild mouse blood samples under field conditions

Hantavirus cardiopulmonary syndrome (HCPS) is an acute, life threatening viral illness that was first recognized in the spring of 1993 during an outbreak in the Four Corners region of the southwest United States. The etiologic agent, Sin Nombre (SN) virus, is a zoonotic infection that is enzootic in...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) 2002-09, Vol.58 (3), p.517-528
Main Authors: Vetcha, Srinivas, Wilkins, Ebtisam, Yates, Terry, Hjelle, Brian
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c392t-945dfcd2425429292fb824fb21022d84e336feab069b5117762a1970de7f45e73
cites
container_end_page 528
container_issue 3
container_start_page 517
container_title Talanta (Oxford)
container_volume 58
creator Vetcha, Srinivas
Wilkins, Ebtisam
Yates, Terry
Hjelle, Brian
description Hantavirus cardiopulmonary syndrome (HCPS) is an acute, life threatening viral illness that was first recognized in the spring of 1993 during an outbreak in the Four Corners region of the southwest United States. The etiologic agent, Sin Nombre (SN) virus, is a zoonotic infection that is enzootic in deer mice ( Peromyscus maniculatus). Both human and rodent infections lead to specific antibody responses, and detection of such antibodies is the mainstay of diagnosis of infection in both species. More than 300 cases of HCPS have been confirmed in 30 states and four Canadian provinces since 1993 outbreak. Forty percent have been fatal. Conventional methods for the detection of hantavirus antibodies require 4–9 h. Since HCPS can rapidly progress to death, there is a clear need for a rapid diagnostic test. Rapid diagnostic tests for the detection of hantavirus infection should be ideally be (a) quick (b) simple to carry out, (c) allowing if possible for use in field conditions. A field-deployable test would have a particular advantage for diagnosis of infection in wild rodents, such as for risk assessments around case-households, as well as potential human diagnostic applications in battlefield situations. A prototype amperometric immunosensor based on highly dispersed immunoelectrode is developed for operation in field conditions on the importance of rapid and sensitive assay for hantavirus infection in mouse blood serum. This study was initiated to simplify and develop effective procedures for screening rodent serum samples in remote areas. A sandwich scheme immunoassay has been developed and used. Naphthol formed as a result of enzymatic reduction of naphthyl phosphate in the presence of alkaline phosphatase label has been detected amperometrically. The performance of the biosensor device is evaluated by testing mice blood samples in the wild under field conditions. The results were compared with the results obtained using the strip immunoblot assay (SIA) and that obtained from Centers for Disease Control and Prevention (CDC). The overall time of analysis is as low as 25 min and statistical analysis of the data indicated promising results. The device can be easily adapted for fast analysis of other microorganisms under non-laboratory conditions, in remote locations and field operations.
doi_str_mv 10.1016/S0039-9140(02)00307-7
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733829946</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914002003077</els_id><sourcerecordid>733829946</sourcerecordid><originalsourceid>FETCH-LOGICAL-c392t-945dfcd2425429292fb824fb21022d84e336feab069b5117762a1970de7f45e73</originalsourceid><addsrcrecordid>eNqFkUuLFTEQhYMozp3Rn6BkI46L1ry601kNMviCAcHHOqSTClPS3bkm3Vfc-dNNz704SwkhVPKdU8UJIc84e80Z7958ZUyaxnDFLpl4VQumG_2A7HivZSNbLR-S3T_kjJyX8oMxJiSTj8kZ703Xa2125M8Xt8dA3Rxogbngggegt7W8hTHQAdN2mzKNdQdYwC-YZprixizugHktVbzgkAJCoTjTX1iFU1oL0GFMqfq6aT_Wt3UOUI1wM_ZpDrhZlSfkUXRjgaen84J8f__u2_XH5ubzh0_Xb28aL41YGqPaEH0QSrRKmLri0AsVB8GZEKFXIGUXwQ2sM0PLudadcNxoFkBH1YKWF-Tl0Xef088VymInLB7G0c1Qh7Vayl4Yo7pKtkfS51RKhmj3GSeXf1vO7Ja9vcvebsFaJuxd9nbr8PzUYR0mCPeqU9gVeHECXPFujNnNHss9J3ujdLsNcHXkoOZxQMi2eITZQ8BcP8CGhP8Z5S8d3KJV</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733829946</pqid></control><display><type>article</type><title>Rapid and sensitive handheld biosensor for detection of hantavirus antibodies in wild mouse blood samples under field conditions</title><source>ScienceDirect Journals</source><creator>Vetcha, Srinivas ; Wilkins, Ebtisam ; Yates, Terry ; Hjelle, Brian</creator><creatorcontrib>Vetcha, Srinivas ; Wilkins, Ebtisam ; Yates, Terry ; Hjelle, Brian</creatorcontrib><description>Hantavirus cardiopulmonary syndrome (HCPS) is an acute, life threatening viral illness that was first recognized in the spring of 1993 during an outbreak in the Four Corners region of the southwest United States. The etiologic agent, Sin Nombre (SN) virus, is a zoonotic infection that is enzootic in deer mice ( Peromyscus maniculatus). Both human and rodent infections lead to specific antibody responses, and detection of such antibodies is the mainstay of diagnosis of infection in both species. More than 300 cases of HCPS have been confirmed in 30 states and four Canadian provinces since 1993 outbreak. Forty percent have been fatal. Conventional methods for the detection of hantavirus antibodies require 4–9 h. Since HCPS can rapidly progress to death, there is a clear need for a rapid diagnostic test. Rapid diagnostic tests for the detection of hantavirus infection should be ideally be (a) quick (b) simple to carry out, (c) allowing if possible for use in field conditions. A field-deployable test would have a particular advantage for diagnosis of infection in wild rodents, such as for risk assessments around case-households, as well as potential human diagnostic applications in battlefield situations. A prototype amperometric immunosensor based on highly dispersed immunoelectrode is developed for operation in field conditions on the importance of rapid and sensitive assay for hantavirus infection in mouse blood serum. This study was initiated to simplify and develop effective procedures for screening rodent serum samples in remote areas. A sandwich scheme immunoassay has been developed and used. Naphthol formed as a result of enzymatic reduction of naphthyl phosphate in the presence of alkaline phosphatase label has been detected amperometrically. The performance of the biosensor device is evaluated by testing mice blood samples in the wild under field conditions. The results were compared with the results obtained using the strip immunoblot assay (SIA) and that obtained from Centers for Disease Control and Prevention (CDC). The overall time of analysis is as low as 25 min and statistical analysis of the data indicated promising results. The device can be easily adapted for fast analysis of other microorganisms under non-laboratory conditions, in remote locations and field operations.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/S0039-9140(02)00307-7</identifier><identifier>PMID: 18968779</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Amperometric detection ; Biological and medical sciences ; Biosensors ; Biotechnology ; Diagnosis ; Field testing ; Fundamental and applied biological sciences. Psychology ; Hantavirus ; Hantavirus cardiopulmonary syndrome ; Methods. Procedures. Technologies ; Portable immunosensor ; Sin Nombre ; Strip immunoblot assay ; Various methods and equipments</subject><ispartof>Talanta (Oxford), 2002-09, Vol.58 (3), p.517-528</ispartof><rights>2002</rights><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c392t-945dfcd2425429292fb824fb21022d84e336feab069b5117762a1970de7f45e73</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13894756$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18968779$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Vetcha, Srinivas</creatorcontrib><creatorcontrib>Wilkins, Ebtisam</creatorcontrib><creatorcontrib>Yates, Terry</creatorcontrib><creatorcontrib>Hjelle, Brian</creatorcontrib><title>Rapid and sensitive handheld biosensor for detection of hantavirus antibodies in wild mouse blood samples under field conditions</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Hantavirus cardiopulmonary syndrome (HCPS) is an acute, life threatening viral illness that was first recognized in the spring of 1993 during an outbreak in the Four Corners region of the southwest United States. The etiologic agent, Sin Nombre (SN) virus, is a zoonotic infection that is enzootic in deer mice ( Peromyscus maniculatus). Both human and rodent infections lead to specific antibody responses, and detection of such antibodies is the mainstay of diagnosis of infection in both species. More than 300 cases of HCPS have been confirmed in 30 states and four Canadian provinces since 1993 outbreak. Forty percent have been fatal. Conventional methods for the detection of hantavirus antibodies require 4–9 h. Since HCPS can rapidly progress to death, there is a clear need for a rapid diagnostic test. Rapid diagnostic tests for the detection of hantavirus infection should be ideally be (a) quick (b) simple to carry out, (c) allowing if possible for use in field conditions. A field-deployable test would have a particular advantage for diagnosis of infection in wild rodents, such as for risk assessments around case-households, as well as potential human diagnostic applications in battlefield situations. A prototype amperometric immunosensor based on highly dispersed immunoelectrode is developed for operation in field conditions on the importance of rapid and sensitive assay for hantavirus infection in mouse blood serum. This study was initiated to simplify and develop effective procedures for screening rodent serum samples in remote areas. A sandwich scheme immunoassay has been developed and used. Naphthol formed as a result of enzymatic reduction of naphthyl phosphate in the presence of alkaline phosphatase label has been detected amperometrically. The performance of the biosensor device is evaluated by testing mice blood samples in the wild under field conditions. The results were compared with the results obtained using the strip immunoblot assay (SIA) and that obtained from Centers for Disease Control and Prevention (CDC). The overall time of analysis is as low as 25 min and statistical analysis of the data indicated promising results. The device can be easily adapted for fast analysis of other microorganisms under non-laboratory conditions, in remote locations and field operations.</description><subject>Amperometric detection</subject><subject>Biological and medical sciences</subject><subject>Biosensors</subject><subject>Biotechnology</subject><subject>Diagnosis</subject><subject>Field testing</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Hantavirus</subject><subject>Hantavirus cardiopulmonary syndrome</subject><subject>Methods. Procedures. Technologies</subject><subject>Portable immunosensor</subject><subject>Sin Nombre</subject><subject>Strip immunoblot assay</subject><subject>Various methods and equipments</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqFkUuLFTEQhYMozp3Rn6BkI46L1ry601kNMviCAcHHOqSTClPS3bkm3Vfc-dNNz704SwkhVPKdU8UJIc84e80Z7958ZUyaxnDFLpl4VQumG_2A7HivZSNbLR-S3T_kjJyX8oMxJiSTj8kZ703Xa2125M8Xt8dA3Rxogbngggegt7W8hTHQAdN2mzKNdQdYwC-YZprixizugHktVbzgkAJCoTjTX1iFU1oL0GFMqfq6aT_Wt3UOUI1wM_ZpDrhZlSfkUXRjgaen84J8f__u2_XH5ubzh0_Xb28aL41YGqPaEH0QSrRKmLri0AsVB8GZEKFXIGUXwQ2sM0PLudadcNxoFkBH1YKWF-Tl0Xef088VymInLB7G0c1Qh7Vayl4Yo7pKtkfS51RKhmj3GSeXf1vO7Ja9vcvebsFaJuxd9nbr8PzUYR0mCPeqU9gVeHECXPFujNnNHss9J3ujdLsNcHXkoOZxQMi2eITZQ8BcP8CGhP8Z5S8d3KJV</recordid><startdate>20020912</startdate><enddate>20020912</enddate><creator>Vetcha, Srinivas</creator><creator>Wilkins, Ebtisam</creator><creator>Yates, Terry</creator><creator>Hjelle, Brian</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20020912</creationdate><title>Rapid and sensitive handheld biosensor for detection of hantavirus antibodies in wild mouse blood samples under field conditions</title><author>Vetcha, Srinivas ; Wilkins, Ebtisam ; Yates, Terry ; Hjelle, Brian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c392t-945dfcd2425429292fb824fb21022d84e336feab069b5117762a1970de7f45e73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Amperometric detection</topic><topic>Biological and medical sciences</topic><topic>Biosensors</topic><topic>Biotechnology</topic><topic>Diagnosis</topic><topic>Field testing</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Hantavirus</topic><topic>Hantavirus cardiopulmonary syndrome</topic><topic>Methods. Procedures. Technologies</topic><topic>Portable immunosensor</topic><topic>Sin Nombre</topic><topic>Strip immunoblot assay</topic><topic>Various methods and equipments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vetcha, Srinivas</creatorcontrib><creatorcontrib>Wilkins, Ebtisam</creatorcontrib><creatorcontrib>Yates, Terry</creatorcontrib><creatorcontrib>Hjelle, Brian</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vetcha, Srinivas</au><au>Wilkins, Ebtisam</au><au>Yates, Terry</au><au>Hjelle, Brian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid and sensitive handheld biosensor for detection of hantavirus antibodies in wild mouse blood samples under field conditions</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2002-09-12</date><risdate>2002</risdate><volume>58</volume><issue>3</issue><spage>517</spage><epage>528</epage><pages>517-528</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>Hantavirus cardiopulmonary syndrome (HCPS) is an acute, life threatening viral illness that was first recognized in the spring of 1993 during an outbreak in the Four Corners region of the southwest United States. The etiologic agent, Sin Nombre (SN) virus, is a zoonotic infection that is enzootic in deer mice ( Peromyscus maniculatus). Both human and rodent infections lead to specific antibody responses, and detection of such antibodies is the mainstay of diagnosis of infection in both species. More than 300 cases of HCPS have been confirmed in 30 states and four Canadian provinces since 1993 outbreak. Forty percent have been fatal. Conventional methods for the detection of hantavirus antibodies require 4–9 h. Since HCPS can rapidly progress to death, there is a clear need for a rapid diagnostic test. Rapid diagnostic tests for the detection of hantavirus infection should be ideally be (a) quick (b) simple to carry out, (c) allowing if possible for use in field conditions. A field-deployable test would have a particular advantage for diagnosis of infection in wild rodents, such as for risk assessments around case-households, as well as potential human diagnostic applications in battlefield situations. A prototype amperometric immunosensor based on highly dispersed immunoelectrode is developed for operation in field conditions on the importance of rapid and sensitive assay for hantavirus infection in mouse blood serum. This study was initiated to simplify and develop effective procedures for screening rodent serum samples in remote areas. A sandwich scheme immunoassay has been developed and used. Naphthol formed as a result of enzymatic reduction of naphthyl phosphate in the presence of alkaline phosphatase label has been detected amperometrically. The performance of the biosensor device is evaluated by testing mice blood samples in the wild under field conditions. The results were compared with the results obtained using the strip immunoblot assay (SIA) and that obtained from Centers for Disease Control and Prevention (CDC). The overall time of analysis is as low as 25 min and statistical analysis of the data indicated promising results. The device can be easily adapted for fast analysis of other microorganisms under non-laboratory conditions, in remote locations and field operations.</abstract><cop>Amsterdam</cop><cop>Oxford</cop><pub>Elsevier B.V</pub><pmid>18968779</pmid><doi>10.1016/S0039-9140(02)00307-7</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2002-09, Vol.58 (3), p.517-528
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733829946
source ScienceDirect Journals
subjects Amperometric detection
Biological and medical sciences
Biosensors
Biotechnology
Diagnosis
Field testing
Fundamental and applied biological sciences. Psychology
Hantavirus
Hantavirus cardiopulmonary syndrome
Methods. Procedures. Technologies
Portable immunosensor
Sin Nombre
Strip immunoblot assay
Various methods and equipments
title Rapid and sensitive handheld biosensor for detection of hantavirus antibodies in wild mouse blood samples under field conditions
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T20%3A13%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20and%20sensitive%20handheld%20biosensor%20for%20detection%20of%20hantavirus%20antibodies%20in%20wild%20mouse%20blood%20samples%20under%20field%20conditions&rft.jtitle=Talanta%20(Oxford)&rft.au=Vetcha,%20Srinivas&rft.date=2002-09-12&rft.volume=58&rft.issue=3&rft.spage=517&rft.epage=528&rft.pages=517-528&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/S0039-9140(02)00307-7&rft_dat=%3Cproquest_cross%3E733829946%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c392t-945dfcd2425429292fb824fb21022d84e336feab069b5117762a1970de7f45e73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=733829946&rft_id=info:pmid/18968779&rfr_iscdi=true