Loading…
Determination of chromium by GFAAS in slurries of fish feces to estimate the apparent digestibility of nutrients in feed used in pisciculture
This paper presents a simple, fast and sensitive method to determine chromic oxide (used as a biological marker of fish feed) in samples of fish feces by GFAAS through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The standard samples of feces and of...
Saved in:
Published in: | Talanta (Oxford) 2006-06, Vol.69 (4), p.1025-1030 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper presents a simple, fast and sensitive method to determine chromic oxide (used as a biological marker of fish feed) in samples of fish feces by GFAAS through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The standard samples of feces and of fish feed containing 0.10–1.00
mg
kg
−1 of Cr
2O
3 were pre-frozen for 1
min in liquid nitrogen and then ground a cryogenic mill for 2
min, which reduced the samples’ grain size to less than 60
μm. The standard slurries were prepared by mixing 20
mg of standard samples of fish feed or feces with 1
mL of a solution containing 0.05% (v/v) of Triton X-100 and 0.50% (v/v) of suprapure HNO
3 directly in the spectrometer's automatic sampling glass. The final concentrations of Cr
2O
3 present in the standard slurries were 2, 4, 8, 16 and 20
μg
L
−1. After sonicating the mixture for 20
s, 10
μL of standard slurries were injected into the graphite tube, whose internal wall was lined with a metallic palladium film that acted as a permanent chemical modifier. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (2%, m/v of feces or feed devoid of minerals) were 0.81 and 2.70
μg
L
−1 of Cr
2O
3 for the standard feces slurries, 0.84 and 2.83
μg
L
−1 of Cr
2O
3 for the standard feed slurries. The proposed method was applied in studies of nutrient digestibility of different fish feeds and its results proved compatible with the results obtained from samples pre-mineralized by acid digestion. |
---|---|
ISSN: | 0039-9140 1873-3573 |
DOI: | 10.1016/j.talanta.2005.12.008 |