Calibration sampling paradox in near infrared spectroscopy: A case study of multi-component powder blend

The objective of this study was to illustrate the sampling paradox resulting from the different strategies of spectral acquisition while preparing and implementing the calibration models for prediction of blend components in multi-component cohesive blends. A D-optimal mixture design was used to cre...

Full description

Saved in:
Bibliographic Details
Published in:International journal of pharmaceutics 2010-08, Vol.395 (1), p.91-97
Main Authors: Karande, A.D., Liew, C.V., Heng, P.W.S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c394t-186d7c77f2da35acf1a49cfad10528c5f9ddf7597bc62d70b0d1d62a03b2eb6c3
cites cdi_FETCH-LOGICAL-c394t-186d7c77f2da35acf1a49cfad10528c5f9ddf7597bc62d70b0d1d62a03b2eb6c3
container_end_page 97
container_issue 1
container_start_page 91
container_title International journal of pharmaceutics
container_volume 395
creator Karande, A.D.
Liew, C.V.
Heng, P.W.S.
description The objective of this study was to illustrate the sampling paradox resulting from the different strategies of spectral acquisition while preparing and implementing the calibration models for prediction of blend components in multi-component cohesive blends. A D-optimal mixture design was used to create 24 blending runs of the formulation consisting of chlorpheniramine maleate, lactose, microcrystalline cellulose and magnesium stearate. Three strategies: (a) laboratory mixing and static spectral acquisition, (b) IBC mixing and static spectral acquisition and (c) IBC mixing and dynamic spectral acquisition were investigated for obtaining the most relevant and representative calibration samples. An optical head comprising a sapphire window mounted on the lid of the IBC was used for static and dynamic NIR spectral acquisition of the powder blends. For laboratory mixed samples, powders were blended for fixed period of 30 min and later on scanned for NIR spectra. For IBC mixed blends, the spectral acquisition was carried out in-line for 2 min and stopped for static spectral acquisition. The same cycle was repeated for the next 28 min. Partial least square (PLS) calibration models for each component were built and ranked according to their calibration statistics. Optimal calibration models were selected from each strategy for each component and used for in-line prediction of blend components of three independent test runs. Although excellent statistics were obtained for the PLS models from the three strategies, significant discrepancies were observed during prediction of the independent blends in real time. Models built using IBC mixed blends and dynamic spectral acquisition resulted in the most accurate predictions for all the blend components, whereas models prepared using static spectral acquisition (laboratory mixed and IBC) showed erroneous prediction results. The prediction performance differences between the models obtained using the different strategies could be explained in the context of relevancy and representative sample collection at the initial stage of calibration model building.
doi_str_mv 10.1016/j.ijpharm.2010.05.011
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733982815</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378517310003546</els_id><sourcerecordid>733982815</sourcerecordid><originalsourceid>FETCH-LOGICAL-c394t-186d7c77f2da35acf1a49cfad10528c5f9ddf7597bc62d70b0d1d62a03b2eb6c3</originalsourceid><addsrcrecordid>eNqFkU1v1DAQhi0EokvhJ4B8QZyy-GMdJ1xQteJLqtRLe7Ym9ph6ldjBToD993W1Cxw5jF5p9Iw9fkzIa862nPH2_WEbDvM95GkrWO0xtWWcPyEb3mnZyJ1un5INk7prFNfygrwo5cAYawWXz8mFYDtdq9uQ-z2MYciwhBRpgWkeQ_xOZ8jg0m8aIo0IuabPkNHRMqNdcio2zccP9IpaKEjLsrojTZ5O67iExqZpThHjQuf0y2Gmw4jRvSTPPIwFX53zktx9_nS7_9pc33z5tr-6bqzsd0vDu9Zpq7UXDqQC6znseuvBcaZEZ5XvnfNa9XqwrXCaDcxx1wpgchA4tFZeknenc-ecfqxYFjOFYnEcIWJai9FS9p3ouKqkOpG2Pqhk9GbOYYJ8NJyZR8fmYM6OzaNjw5Spjuvcm_MN6zCh-zv1R2oF3p4BKBbGqi7aUP5xkvH6KW3lPp44rD5-Bsym2IDRogu5ajYuhf-s8gDrkJ8K</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733982815</pqid></control><display><type>article</type><title>Calibration sampling paradox in near infrared spectroscopy: A case study of multi-component powder blend</title><source>ScienceDirect Journals</source><creator>Karande, A.D. ; Liew, C.V. ; Heng, P.W.S.</creator><creatorcontrib>Karande, A.D. ; Liew, C.V. ; Heng, P.W.S.</creatorcontrib><description>The objective of this study was to illustrate the sampling paradox resulting from the different strategies of spectral acquisition while preparing and implementing the calibration models for prediction of blend components in multi-component cohesive blends. A D-optimal mixture design was used to create 24 blending runs of the formulation consisting of chlorpheniramine maleate, lactose, microcrystalline cellulose and magnesium stearate. Three strategies: (a) laboratory mixing and static spectral acquisition, (b) IBC mixing and static spectral acquisition and (c) IBC mixing and dynamic spectral acquisition were investigated for obtaining the most relevant and representative calibration samples. An optical head comprising a sapphire window mounted on the lid of the IBC was used for static and dynamic NIR spectral acquisition of the powder blends. For laboratory mixed samples, powders were blended for fixed period of 30 min and later on scanned for NIR spectra. For IBC mixed blends, the spectral acquisition was carried out in-line for 2 min and stopped for static spectral acquisition. The same cycle was repeated for the next 28 min. Partial least square (PLS) calibration models for each component were built and ranked according to their calibration statistics. Optimal calibration models were selected from each strategy for each component and used for in-line prediction of blend components of three independent test runs. Although excellent statistics were obtained for the PLS models from the three strategies, significant discrepancies were observed during prediction of the independent blends in real time. Models built using IBC mixed blends and dynamic spectral acquisition resulted in the most accurate predictions for all the blend components, whereas models prepared using static spectral acquisition (laboratory mixed and IBC) showed erroneous prediction results. The prediction performance differences between the models obtained using the different strategies could be explained in the context of relevancy and representative sample collection at the initial stage of calibration model building.</description><identifier>ISSN: 0378-5173</identifier><identifier>EISSN: 1873-3476</identifier><identifier>DOI: 10.1016/j.ijpharm.2010.05.011</identifier><identifier>PMID: 20472048</identifier><identifier>CODEN: IJPHDE</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Biological and medical sciences ; Blending ; Calibration ; Cellulose - chemistry ; Chemistry, Pharmaceutical ; Chlorpheniramine - chemistry ; Dynamic spectral acquisition ; General pharmacology ; Lactose - chemistry ; Least-Squares Analysis ; Medical sciences ; Models, Statistical ; Multivariate calibration models ; NIR ; Pharmaceutical technology. Pharmaceutical industry ; Pharmacology. Drug treatments ; Powders ; Sampling ; Spectroscopy, Near-Infrared - standards ; Static spectral acquisition ; Stearic Acids - chemistry ; Technology, Pharmaceutical - methods ; Technology, Pharmaceutical - standards</subject><ispartof>International journal of pharmaceutics, 2010-08, Vol.395 (1), p.91-97</ispartof><rights>2010 Elsevier B.V.</rights><rights>2015 INIST-CNRS</rights><rights>Copyright (c) 2010 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c394t-186d7c77f2da35acf1a49cfad10528c5f9ddf7597bc62d70b0d1d62a03b2eb6c3</citedby><cites>FETCH-LOGICAL-c394t-186d7c77f2da35acf1a49cfad10528c5f9ddf7597bc62d70b0d1d62a03b2eb6c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=23015176$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20472048$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Karande, A.D.</creatorcontrib><creatorcontrib>Liew, C.V.</creatorcontrib><creatorcontrib>Heng, P.W.S.</creatorcontrib><title>Calibration sampling paradox in near infrared spectroscopy: A case study of multi-component powder blend</title><title>International journal of pharmaceutics</title><addtitle>Int J Pharm</addtitle><description>The objective of this study was to illustrate the sampling paradox resulting from the different strategies of spectral acquisition while preparing and implementing the calibration models for prediction of blend components in multi-component cohesive blends. A D-optimal mixture design was used to create 24 blending runs of the formulation consisting of chlorpheniramine maleate, lactose, microcrystalline cellulose and magnesium stearate. Three strategies: (a) laboratory mixing and static spectral acquisition, (b) IBC mixing and static spectral acquisition and (c) IBC mixing and dynamic spectral acquisition were investigated for obtaining the most relevant and representative calibration samples. An optical head comprising a sapphire window mounted on the lid of the IBC was used for static and dynamic NIR spectral acquisition of the powder blends. For laboratory mixed samples, powders were blended for fixed period of 30 min and later on scanned for NIR spectra. For IBC mixed blends, the spectral acquisition was carried out in-line for 2 min and stopped for static spectral acquisition. The same cycle was repeated for the next 28 min. Partial least square (PLS) calibration models for each component were built and ranked according to their calibration statistics. Optimal calibration models were selected from each strategy for each component and used for in-line prediction of blend components of three independent test runs. Although excellent statistics were obtained for the PLS models from the three strategies, significant discrepancies were observed during prediction of the independent blends in real time. Models built using IBC mixed blends and dynamic spectral acquisition resulted in the most accurate predictions for all the blend components, whereas models prepared using static spectral acquisition (laboratory mixed and IBC) showed erroneous prediction results. The prediction performance differences between the models obtained using the different strategies could be explained in the context of relevancy and representative sample collection at the initial stage of calibration model building.</description><subject>Biological and medical sciences</subject><subject>Blending</subject><subject>Calibration</subject><subject>Cellulose - chemistry</subject><subject>Chemistry, Pharmaceutical</subject><subject>Chlorpheniramine - chemistry</subject><subject>Dynamic spectral acquisition</subject><subject>General pharmacology</subject><subject>Lactose - chemistry</subject><subject>Least-Squares Analysis</subject><subject>Medical sciences</subject><subject>Models, Statistical</subject><subject>Multivariate calibration models</subject><subject>NIR</subject><subject>Pharmaceutical technology. Pharmaceutical industry</subject><subject>Pharmacology. Drug treatments</subject><subject>Powders</subject><subject>Sampling</subject><subject>Spectroscopy, Near-Infrared - standards</subject><subject>Static spectral acquisition</subject><subject>Stearic Acids - chemistry</subject><subject>Technology, Pharmaceutical - methods</subject><subject>Technology, Pharmaceutical - standards</subject><issn>0378-5173</issn><issn>1873-3476</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqFkU1v1DAQhi0EokvhJ4B8QZyy-GMdJ1xQteJLqtRLe7Ym9ph6ldjBToD993W1Cxw5jF5p9Iw9fkzIa862nPH2_WEbDvM95GkrWO0xtWWcPyEb3mnZyJ1un5INk7prFNfygrwo5cAYawWXz8mFYDtdq9uQ-z2MYciwhBRpgWkeQ_xOZ8jg0m8aIo0IuabPkNHRMqNdcio2zccP9IpaKEjLsrojTZ5O67iExqZpThHjQuf0y2Gmw4jRvSTPPIwFX53zktx9_nS7_9pc33z5tr-6bqzsd0vDu9Zpq7UXDqQC6znseuvBcaZEZ5XvnfNa9XqwrXCaDcxx1wpgchA4tFZeknenc-ecfqxYFjOFYnEcIWJai9FS9p3ouKqkOpG2Pqhk9GbOYYJ8NJyZR8fmYM6OzaNjw5Spjuvcm_MN6zCh-zv1R2oF3p4BKBbGqi7aUP5xkvH6KW3lPp44rD5-Bsym2IDRogu5ajYuhf-s8gDrkJ8K</recordid><startdate>20100816</startdate><enddate>20100816</enddate><creator>Karande, A.D.</creator><creator>Liew, C.V.</creator><creator>Heng, P.W.S.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20100816</creationdate><title>Calibration sampling paradox in near infrared spectroscopy: A case study of multi-component powder blend</title><author>Karande, A.D. ; Liew, C.V. ; Heng, P.W.S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c394t-186d7c77f2da35acf1a49cfad10528c5f9ddf7597bc62d70b0d1d62a03b2eb6c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Biological and medical sciences</topic><topic>Blending</topic><topic>Calibration</topic><topic>Cellulose - chemistry</topic><topic>Chemistry, Pharmaceutical</topic><topic>Chlorpheniramine - chemistry</topic><topic>Dynamic spectral acquisition</topic><topic>General pharmacology</topic><topic>Lactose - chemistry</topic><topic>Least-Squares Analysis</topic><topic>Medical sciences</topic><topic>Models, Statistical</topic><topic>Multivariate calibration models</topic><topic>NIR</topic><topic>Pharmaceutical technology. Pharmaceutical industry</topic><topic>Pharmacology. Drug treatments</topic><topic>Powders</topic><topic>Sampling</topic><topic>Spectroscopy, Near-Infrared - standards</topic><topic>Static spectral acquisition</topic><topic>Stearic Acids - chemistry</topic><topic>Technology, Pharmaceutical - methods</topic><topic>Technology, Pharmaceutical - standards</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Karande, A.D.</creatorcontrib><creatorcontrib>Liew, C.V.</creatorcontrib><creatorcontrib>Heng, P.W.S.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of pharmaceutics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Karande, A.D.</au><au>Liew, C.V.</au><au>Heng, P.W.S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibration sampling paradox in near infrared spectroscopy: A case study of multi-component powder blend</atitle><jtitle>International journal of pharmaceutics</jtitle><addtitle>Int J Pharm</addtitle><date>2010-08-16</date><risdate>2010</risdate><volume>395</volume><issue>1</issue><spage>91</spage><epage>97</epage><pages>91-97</pages><issn>0378-5173</issn><eissn>1873-3476</eissn><coden>IJPHDE</coden><abstract>The objective of this study was to illustrate the sampling paradox resulting from the different strategies of spectral acquisition while preparing and implementing the calibration models for prediction of blend components in multi-component cohesive blends. A D-optimal mixture design was used to create 24 blending runs of the formulation consisting of chlorpheniramine maleate, lactose, microcrystalline cellulose and magnesium stearate. Three strategies: (a) laboratory mixing and static spectral acquisition, (b) IBC mixing and static spectral acquisition and (c) IBC mixing and dynamic spectral acquisition were investigated for obtaining the most relevant and representative calibration samples. An optical head comprising a sapphire window mounted on the lid of the IBC was used for static and dynamic NIR spectral acquisition of the powder blends. For laboratory mixed samples, powders were blended for fixed period of 30 min and later on scanned for NIR spectra. For IBC mixed blends, the spectral acquisition was carried out in-line for 2 min and stopped for static spectral acquisition. The same cycle was repeated for the next 28 min. Partial least square (PLS) calibration models for each component were built and ranked according to their calibration statistics. Optimal calibration models were selected from each strategy for each component and used for in-line prediction of blend components of three independent test runs. Although excellent statistics were obtained for the PLS models from the three strategies, significant discrepancies were observed during prediction of the independent blends in real time. Models built using IBC mixed blends and dynamic spectral acquisition resulted in the most accurate predictions for all the blend components, whereas models prepared using static spectral acquisition (laboratory mixed and IBC) showed erroneous prediction results. The prediction performance differences between the models obtained using the different strategies could be explained in the context of relevancy and representative sample collection at the initial stage of calibration model building.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>20472048</pmid><doi>10.1016/j.ijpharm.2010.05.011</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-5173
ispartof International journal of pharmaceutics, 2010-08, Vol.395 (1), p.91-97
issn 0378-5173
1873-3476
language eng
recordid cdi_proquest_miscellaneous_733982815
source ScienceDirect Journals
subjects Biological and medical sciences
Blending
Calibration
Cellulose - chemistry
Chemistry, Pharmaceutical
Chlorpheniramine - chemistry
Dynamic spectral acquisition
General pharmacology
Lactose - chemistry
Least-Squares Analysis
Medical sciences
Models, Statistical
Multivariate calibration models
NIR
Pharmaceutical technology. Pharmaceutical industry
Pharmacology. Drug treatments
Powders
Sampling
Spectroscopy, Near-Infrared - standards
Static spectral acquisition
Stearic Acids - chemistry
Technology, Pharmaceutical - methods
Technology, Pharmaceutical - standards
title Calibration sampling paradox in near infrared spectroscopy: A case study of multi-component powder blend
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T12%3A35%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibration%20sampling%20paradox%20in%20near%20infrared%20spectroscopy:%20A%20case%20study%20of%20multi-component%20powder%20blend&rft.jtitle=International%20journal%20of%20pharmaceutics&rft.au=Karande,%20A.D.&rft.date=2010-08-16&rft.volume=395&rft.issue=1&rft.spage=91&rft.epage=97&rft.pages=91-97&rft.issn=0378-5173&rft.eissn=1873-3476&rft.coden=IJPHDE&rft_id=info:doi/10.1016/j.ijpharm.2010.05.011&rft_dat=%3Cproquest_cross%3E733982815%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c394t-186d7c77f2da35acf1a49cfad10528c5f9ddf7597bc62d70b0d1d62a03b2eb6c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=733982815&rft_id=info:pmid/20472048&rfr_iscdi=true