Correlation Between Screening for Obstructive Sleep Apnea Using a Portable Device Versus Polysomnography Testing in a Commercial Driving Population

Objective: To compare the accuracy of portable monitoring for obstructive sleep apnea (OSA) with polysomnography (PSG) in commercial drivers. Methods: A consecutive case series of drivers were screened far OSA using recent validated consensus conference criteria at a single occupational medicine cli...

Full description

Saved in:
Bibliographic Details
Published in:Journal of occupational and environmental medicine 2009-10, Vol.51 (10), p.1145-1150
Main Authors: Watkins, Marc R., Talmage, James B., Thiese, Matthew S., Hudson, Toney B., Hegmann, Kurt T.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c5002-7dbd201d66d33e47be85e2ab5251c0acf887a353f92cb1b280c607fa7c5bddff3
cites cdi_FETCH-LOGICAL-c5002-7dbd201d66d33e47be85e2ab5251c0acf887a353f92cb1b280c607fa7c5bddff3
container_end_page 1150
container_issue 10
container_start_page 1145
container_title Journal of occupational and environmental medicine
container_volume 51
creator Watkins, Marc R.
Talmage, James B.
Thiese, Matthew S.
Hudson, Toney B.
Hegmann, Kurt T.
description Objective: To compare the accuracy of portable monitoring for obstructive sleep apnea (OSA) with polysomnography (PSG) in commercial drivers. Methods: A consecutive case series of drivers were screened far OSA using recent validated consensus conference criteria at a single occupational medicine clinic; those screening positive were tested with a portable OSA screening device while awaiting PSG. Results: Three hundred forty-six drivers were screened and 34 completed PSG and portable monitoring. Comparing the portable device to PSG at a definition of OSA as an apnea hypopnea index (AHI) ≥ 15, positive predictive value is 0.64 with a 0.87 negative predictive value. Positive likelihood ratio is 4.20. Linear regression model found statistically significant relationship (P = 0.0004) between the portable device and PSG AHI values. Conclusion: Although not perfect, portable monitoring may be useful in further stratifying risk in drivers who have a high probability of having OSA.
doi_str_mv 10.1097/JOM.0b013e3181b68d52
format article
fullrecord <record><control><sourceid>jstor_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_734080407</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><jstor_id>45009536</jstor_id><sourcerecordid>45009536</sourcerecordid><originalsourceid>FETCH-LOGICAL-c5002-7dbd201d66d33e47be85e2ab5251c0acf887a353f92cb1b280c607fa7c5bddff3</originalsourceid><addsrcrecordid>eNqFkl9r2zAUxc3YWLtu32AbYjD2lO5Ksiz5sUu7f3Sk0HavRpKvG2ey5Up2Qj5Hv_AUEjroy56uuPzO4XCPsuwthVMKpfz8c_HrFAxQjpwqagpVC_YsO6aCFzNR5up5eoMsZkwKdpS9inEFQAUF8TI7oqVURQn8OHuY-xDQ6bH1PfmC4waxJ9c2pNH2d6TxgSxMHMNkx3aN5NohDuRs6FGT27gjNLnyYdTGITnHdWuR_MYQp5jWbht91_u7oIflltxgHHeCtk-aue86DLbVjpyHdr3bX_lh2ud4nb1otIv45jBPstuvFzfz77PLxbcf87PLmRUAbCZrUzOgdVHUnGMuDSqBTBvBBLWgbaOU1FzwpmTWUMMU2AJko6UVpq6bhp9kn_a-Q_D3U4pXdW206Jzu0U-xkjwHBTnIRH54Qq78FPoUrmKUFVSmHAnK95ANPsaATTWEttNhW1GodpVVqbLqaWVJ9v7gPZkO63-iQ0cJ-HgAdLTaNUH3to2PHGPAQVCVOLXnNt6NqYM_btpgqJao3bj8X4Z3e-kqjj48WufpzmX6T_wvDO29_w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>212617201</pqid></control><display><type>article</type><title>Correlation Between Screening for Obstructive Sleep Apnea Using a Portable Device Versus Polysomnography Testing in a Commercial Driving Population</title><source>JSTOR</source><creator>Watkins, Marc R. ; Talmage, James B. ; Thiese, Matthew S. ; Hudson, Toney B. ; Hegmann, Kurt T.</creator><creatorcontrib>Watkins, Marc R. ; Talmage, James B. ; Thiese, Matthew S. ; Hudson, Toney B. ; Hegmann, Kurt T.</creatorcontrib><description>Objective: To compare the accuracy of portable monitoring for obstructive sleep apnea (OSA) with polysomnography (PSG) in commercial drivers. Methods: A consecutive case series of drivers were screened far OSA using recent validated consensus conference criteria at a single occupational medicine clinic; those screening positive were tested with a portable OSA screening device while awaiting PSG. Results: Three hundred forty-six drivers were screened and 34 completed PSG and portable monitoring. Comparing the portable device to PSG at a definition of OSA as an apnea hypopnea index (AHI) ≥ 15, positive predictive value is 0.64 with a 0.87 negative predictive value. Positive likelihood ratio is 4.20. Linear regression model found statistically significant relationship (P = 0.0004) between the portable device and PSG AHI values. Conclusion: Although not perfect, portable monitoring may be useful in further stratifying risk in drivers who have a high probability of having OSA.</description><identifier>ISSN: 1076-2752</identifier><identifier>EISSN: 1536-5948</identifier><identifier>DOI: 10.1097/JOM.0b013e3181b68d52</identifier><identifier>PMID: 19786903</identifier><identifier>CODEN: JOEMFM</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott Williams &amp; Wilkins</publisher><subject>Accuracy ; Adult ; Automobile drivers ; Automobile Driving ; Biological and medical sciences ; Humans ; Medical sciences ; Middle Aged ; Monitoring, Ambulatory - instrumentation ; Motor Vehicles ; Occupations ; ORIGINAL ARTICLES ; Pneumology ; Polysomnography ; Prospective Studies ; Respiratory system : syndromes and miscellaneous diseases ; Sleep apnea ; Sleep Apnea, Obstructive - diagnosis ; Transportation</subject><ispartof>Journal of occupational and environmental medicine, 2009-10, Vol.51 (10), p.1145-1150</ispartof><rights>Copyright © 2009 American College of Occupational and Environmental Medicine</rights><rights>2009The American College of Occupational and Environmental Medicine</rights><rights>2009 INIST-CNRS</rights><rights>Copyright Lippincott Williams &amp; Wilkins Oct 2009</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c5002-7dbd201d66d33e47be85e2ab5251c0acf887a353f92cb1b280c607fa7c5bddff3</citedby><cites>FETCH-LOGICAL-c5002-7dbd201d66d33e47be85e2ab5251c0acf887a353f92cb1b280c607fa7c5bddff3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.jstor.org/stable/pdf/45009536$$EPDF$$P50$$Gjstor$$H</linktopdf><linktohtml>$$Uhttps://www.jstor.org/stable/45009536$$EHTML$$P50$$Gjstor$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,58213,58446</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=22030518$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19786903$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Watkins, Marc R.</creatorcontrib><creatorcontrib>Talmage, James B.</creatorcontrib><creatorcontrib>Thiese, Matthew S.</creatorcontrib><creatorcontrib>Hudson, Toney B.</creatorcontrib><creatorcontrib>Hegmann, Kurt T.</creatorcontrib><title>Correlation Between Screening for Obstructive Sleep Apnea Using a Portable Device Versus Polysomnography Testing in a Commercial Driving Population</title><title>Journal of occupational and environmental medicine</title><addtitle>J Occup Environ Med</addtitle><description>Objective: To compare the accuracy of portable monitoring for obstructive sleep apnea (OSA) with polysomnography (PSG) in commercial drivers. Methods: A consecutive case series of drivers were screened far OSA using recent validated consensus conference criteria at a single occupational medicine clinic; those screening positive were tested with a portable OSA screening device while awaiting PSG. Results: Three hundred forty-six drivers were screened and 34 completed PSG and portable monitoring. Comparing the portable device to PSG at a definition of OSA as an apnea hypopnea index (AHI) ≥ 15, positive predictive value is 0.64 with a 0.87 negative predictive value. Positive likelihood ratio is 4.20. Linear regression model found statistically significant relationship (P = 0.0004) between the portable device and PSG AHI values. Conclusion: Although not perfect, portable monitoring may be useful in further stratifying risk in drivers who have a high probability of having OSA.</description><subject>Accuracy</subject><subject>Adult</subject><subject>Automobile drivers</subject><subject>Automobile Driving</subject><subject>Biological and medical sciences</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Monitoring, Ambulatory - instrumentation</subject><subject>Motor Vehicles</subject><subject>Occupations</subject><subject>ORIGINAL ARTICLES</subject><subject>Pneumology</subject><subject>Polysomnography</subject><subject>Prospective Studies</subject><subject>Respiratory system : syndromes and miscellaneous diseases</subject><subject>Sleep apnea</subject><subject>Sleep Apnea, Obstructive - diagnosis</subject><subject>Transportation</subject><issn>1076-2752</issn><issn>1536-5948</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNqFkl9r2zAUxc3YWLtu32AbYjD2lO5Ksiz5sUu7f3Sk0HavRpKvG2ey5Up2Qj5Hv_AUEjroy56uuPzO4XCPsuwthVMKpfz8c_HrFAxQjpwqagpVC_YsO6aCFzNR5up5eoMsZkwKdpS9inEFQAUF8TI7oqVURQn8OHuY-xDQ6bH1PfmC4waxJ9c2pNH2d6TxgSxMHMNkx3aN5NohDuRs6FGT27gjNLnyYdTGITnHdWuR_MYQp5jWbht91_u7oIflltxgHHeCtk-aue86DLbVjpyHdr3bX_lh2ud4nb1otIv45jBPstuvFzfz77PLxbcf87PLmRUAbCZrUzOgdVHUnGMuDSqBTBvBBLWgbaOU1FzwpmTWUMMU2AJko6UVpq6bhp9kn_a-Q_D3U4pXdW206Jzu0U-xkjwHBTnIRH54Qq78FPoUrmKUFVSmHAnK95ANPsaATTWEttNhW1GodpVVqbLqaWVJ9v7gPZkO63-iQ0cJ-HgAdLTaNUH3to2PHGPAQVCVOLXnNt6NqYM_btpgqJao3bj8X4Z3e-kqjj48WufpzmX6T_wvDO29_w</recordid><startdate>200910</startdate><enddate>200910</enddate><creator>Watkins, Marc R.</creator><creator>Talmage, James B.</creator><creator>Thiese, Matthew S.</creator><creator>Hudson, Toney B.</creator><creator>Hegmann, Kurt T.</creator><general>Lippincott Williams &amp; Wilkins</general><general>The American College of Occupational and Environmental Medicine</general><general>Lippincott Williams &amp; Wilkins Ovid Technologies</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T2</scope><scope>7U7</scope><scope>7U9</scope><scope>C1K</scope><scope>H94</scope><scope>K9.</scope><scope>7X8</scope></search><sort><creationdate>200910</creationdate><title>Correlation Between Screening for Obstructive Sleep Apnea Using a Portable Device Versus Polysomnography Testing in a Commercial Driving Population</title><author>Watkins, Marc R. ; Talmage, James B. ; Thiese, Matthew S. ; Hudson, Toney B. ; Hegmann, Kurt T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c5002-7dbd201d66d33e47be85e2ab5251c0acf887a353f92cb1b280c607fa7c5bddff3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Accuracy</topic><topic>Adult</topic><topic>Automobile drivers</topic><topic>Automobile Driving</topic><topic>Biological and medical sciences</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Monitoring, Ambulatory - instrumentation</topic><topic>Motor Vehicles</topic><topic>Occupations</topic><topic>ORIGINAL ARTICLES</topic><topic>Pneumology</topic><topic>Polysomnography</topic><topic>Prospective Studies</topic><topic>Respiratory system : syndromes and miscellaneous diseases</topic><topic>Sleep apnea</topic><topic>Sleep Apnea, Obstructive - diagnosis</topic><topic>Transportation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Watkins, Marc R.</creatorcontrib><creatorcontrib>Talmage, James B.</creatorcontrib><creatorcontrib>Thiese, Matthew S.</creatorcontrib><creatorcontrib>Hudson, Toney B.</creatorcontrib><creatorcontrib>Hegmann, Kurt T.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of occupational and environmental medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Watkins, Marc R.</au><au>Talmage, James B.</au><au>Thiese, Matthew S.</au><au>Hudson, Toney B.</au><au>Hegmann, Kurt T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Correlation Between Screening for Obstructive Sleep Apnea Using a Portable Device Versus Polysomnography Testing in a Commercial Driving Population</atitle><jtitle>Journal of occupational and environmental medicine</jtitle><addtitle>J Occup Environ Med</addtitle><date>2009-10</date><risdate>2009</risdate><volume>51</volume><issue>10</issue><spage>1145</spage><epage>1150</epage><pages>1145-1150</pages><issn>1076-2752</issn><eissn>1536-5948</eissn><coden>JOEMFM</coden><abstract>Objective: To compare the accuracy of portable monitoring for obstructive sleep apnea (OSA) with polysomnography (PSG) in commercial drivers. Methods: A consecutive case series of drivers were screened far OSA using recent validated consensus conference criteria at a single occupational medicine clinic; those screening positive were tested with a portable OSA screening device while awaiting PSG. Results: Three hundred forty-six drivers were screened and 34 completed PSG and portable monitoring. Comparing the portable device to PSG at a definition of OSA as an apnea hypopnea index (AHI) ≥ 15, positive predictive value is 0.64 with a 0.87 negative predictive value. Positive likelihood ratio is 4.20. Linear regression model found statistically significant relationship (P = 0.0004) between the portable device and PSG AHI values. Conclusion: Although not perfect, portable monitoring may be useful in further stratifying risk in drivers who have a high probability of having OSA.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott Williams &amp; Wilkins</pub><pmid>19786903</pmid><doi>10.1097/JOM.0b013e3181b68d52</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1076-2752
ispartof Journal of occupational and environmental medicine, 2009-10, Vol.51 (10), p.1145-1150
issn 1076-2752
1536-5948
language eng
recordid cdi_proquest_miscellaneous_734080407
source JSTOR
subjects Accuracy
Adult
Automobile drivers
Automobile Driving
Biological and medical sciences
Humans
Medical sciences
Middle Aged
Monitoring, Ambulatory - instrumentation
Motor Vehicles
Occupations
ORIGINAL ARTICLES
Pneumology
Polysomnography
Prospective Studies
Respiratory system : syndromes and miscellaneous diseases
Sleep apnea
Sleep Apnea, Obstructive - diagnosis
Transportation
title Correlation Between Screening for Obstructive Sleep Apnea Using a Portable Device Versus Polysomnography Testing in a Commercial Driving Population
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T15%3A56%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstor_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Correlation%20Between%20Screening%20for%20Obstructive%20Sleep%20Apnea%20Using%20a%20Portable%20Device%20Versus%20Polysomnography%20Testing%20in%20a%20Commercial%20Driving%20Population&rft.jtitle=Journal%20of%20occupational%20and%20environmental%20medicine&rft.au=Watkins,%20Marc%20R.&rft.date=2009-10&rft.volume=51&rft.issue=10&rft.spage=1145&rft.epage=1150&rft.pages=1145-1150&rft.issn=1076-2752&rft.eissn=1536-5948&rft.coden=JOEMFM&rft_id=info:doi/10.1097/JOM.0b013e3181b68d52&rft_dat=%3Cjstor_proqu%3E45009536%3C/jstor_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c5002-7dbd201d66d33e47be85e2ab5251c0acf887a353f92cb1b280c607fa7c5bddff3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=212617201&rft_id=info:pmid/19786903&rft_jstor_id=45009536&rfr_iscdi=true