Loading…

A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome

A randomized trial was done to compare single-chamber atrial (AAI) and dual-chamber (DDD) pacing in patients with sick sinus syndrome (SSS). Primary end points were changes in left atrial (LA) size and left ventricular (LV) size and function as measured by M-mode echocardiography. In patients with S...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the American College of Cardiology 2003-08, Vol.42 (4), p.614-623
Main Authors: Nielsen, Jens C, Kristensen, Lene, Andersen, Henning R, Mortensen, Peter T, Pedersen, Ole L, Pedersen, Anders K
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c259t-d21af6a11e3392be654e53de8ec9d08ed14008b5b418b4ca92d46dc79c85eb8c3
cites
container_end_page 623
container_issue 4
container_start_page 614
container_title Journal of the American College of Cardiology
container_volume 42
creator Nielsen, Jens C
Kristensen, Lene
Andersen, Henning R
Mortensen, Peter T
Pedersen, Ole L
Pedersen, Anders K
description A randomized trial was done to compare single-chamber atrial (AAI) and dual-chamber (DDD) pacing in patients with sick sinus syndrome (SSS). Primary end points were changes in left atrial (LA) size and left ventricular (LV) size and function as measured by M-mode echocardiography. In patients with SSS and normal atrioventricular conduction, it is still not clear whether the optimal pacing mode is AAI or DDD pacing. A total of 177 consecutive patients (mean age 74 +/- 9 years, 73 men) were randomized to treatment with one of three rate-adaptive (R) pacemakers: AAIR (n = 54), DDDR with a short atrioventricular delay (n = 60) (DDDR-s), or DDDR with a fixed long atrioventricular delay (n = 63) (DDDR-l). Before pacemaker implantation and at each follow-up, M-mode echocardiography was done to measure LA and LV diameters. Left ventricular fractional shortening (LVFS) was calculated. Analysis was on an intention-to-treat basis. Mean follow-up was 2.9 +/- 1.1 years. In the AAIR group, no significant changes were observed in LA or LV diameters or LVFS from baseline to last follow-up. In both DDDR groups, LA diameter increased significantly (p < 0.05), and in the DDDR-s group, LVFS decreased significantly (p < 0.01). Atrial fibrillation was significantly less common in the AAIR group, 7.4% versus 23.3% in the DDDR-s group versus 17.5% in the DDDR-l group (p = 0.03, log-rank test). Mortality, thromboembolism, and congestive heart failure did not differ between groups. During a mean follow-up of 2.9 +/- 1.1 years, DDDR pacing causes increased LA diameter, and DDDR pacing with a short atrioventricular delay also causes decreased LVFS. No changes occur in LA or LV diameters or LVFS during AAIR pacing. Atrial fibrillation is significantly less common during AAIR pacing.
doi_str_mv 10.1016/S0735-1097(03)00757-5
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_73521137</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73521137</sourcerecordid><originalsourceid>FETCH-LOGICAL-c259t-d21af6a11e3392be654e53de8ec9d08ed14008b5b418b4ca92d46dc79c85eb8c3</originalsourceid><addsrcrecordid>eNo9UMtOwzAQ9AFES-ETQD4hOATsOE9uVcVLqsQBOEfOetsaEjvYDqh8CN-LxeuyK-3MzoyGkCPOzjnjxcUDK0WecFaXp0ycMVbmZZLvkOn_eUL2vX9mjBUVr_fIhKe1SPOaTcnnnDpplO31ByoKth-k094aaldUBqdlRyNM1Si7BDayb9HRQYI2a6oN5WUZf4xHGIN-w4gEjSZ4-q7DhnoNL3GY0VO_NcrZHi8pwsaCdErbtZPDRsO3PnTaaIhmdgwxBB6Q3ZXsPB7-7hl5ur56XNwmy_ubu8V8mUCMHxKVcrkqJOcoRJ22WOQZ5kJhhVArVqHiGWNVm7cZr9oMZJ2qrFBQ1lDl2FYgZuTkR3dw9nVEH5pee8Cukwbt6JtYYMq5KCPx-Jc4tj2qZnC6l27b_DUpvgB9oHf8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73521137</pqid></control><display><type>article</type><title>A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome</title><source>BACON - Elsevier - GLOBAL_SCIENCEDIRECT-OPENACCESS</source><creator>Nielsen, Jens C ; Kristensen, Lene ; Andersen, Henning R ; Mortensen, Peter T ; Pedersen, Ole L ; Pedersen, Anders K</creator><creatorcontrib>Nielsen, Jens C ; Kristensen, Lene ; Andersen, Henning R ; Mortensen, Peter T ; Pedersen, Ole L ; Pedersen, Anders K</creatorcontrib><description>A randomized trial was done to compare single-chamber atrial (AAI) and dual-chamber (DDD) pacing in patients with sick sinus syndrome (SSS). Primary end points were changes in left atrial (LA) size and left ventricular (LV) size and function as measured by M-mode echocardiography. In patients with SSS and normal atrioventricular conduction, it is still not clear whether the optimal pacing mode is AAI or DDD pacing. A total of 177 consecutive patients (mean age 74 +/- 9 years, 73 men) were randomized to treatment with one of three rate-adaptive (R) pacemakers: AAIR (n = 54), DDDR with a short atrioventricular delay (n = 60) (DDDR-s), or DDDR with a fixed long atrioventricular delay (n = 63) (DDDR-l). Before pacemaker implantation and at each follow-up, M-mode echocardiography was done to measure LA and LV diameters. Left ventricular fractional shortening (LVFS) was calculated. Analysis was on an intention-to-treat basis. Mean follow-up was 2.9 +/- 1.1 years. In the AAIR group, no significant changes were observed in LA or LV diameters or LVFS from baseline to last follow-up. In both DDDR groups, LA diameter increased significantly (p &lt; 0.05), and in the DDDR-s group, LVFS decreased significantly (p &lt; 0.01). Atrial fibrillation was significantly less common in the AAIR group, 7.4% versus 23.3% in the DDDR-s group versus 17.5% in the DDDR-l group (p = 0.03, log-rank test). Mortality, thromboembolism, and congestive heart failure did not differ between groups. During a mean follow-up of 2.9 +/- 1.1 years, DDDR pacing causes increased LA diameter, and DDDR pacing with a short atrioventricular delay also causes decreased LVFS. No changes occur in LA or LV diameters or LVFS during AAIR pacing. Atrial fibrillation is significantly less common during AAIR pacing.</description><identifier>ISSN: 0735-1097</identifier><identifier>DOI: 10.1016/S0735-1097(03)00757-5</identifier><identifier>PMID: 12932590</identifier><language>eng</language><publisher>United States</publisher><subject>Aged ; Aged, 80 and over ; Body Weights and Measures ; Cardiac Pacing, Artificial - methods ; Echocardiography ; Female ; Heart Atria - diagnostic imaging ; Heart Atria - physiopathology ; Heart Ventricles - diagnostic imaging ; Heart Ventricles - physiopathology ; Humans ; Male ; Middle Aged ; Sick Sinus Syndrome - diagnostic imaging ; Sick Sinus Syndrome - therapy</subject><ispartof>Journal of the American College of Cardiology, 2003-08, Vol.42 (4), p.614-623</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c259t-d21af6a11e3392be654e53de8ec9d08ed14008b5b418b4ca92d46dc79c85eb8c3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12932590$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nielsen, Jens C</creatorcontrib><creatorcontrib>Kristensen, Lene</creatorcontrib><creatorcontrib>Andersen, Henning R</creatorcontrib><creatorcontrib>Mortensen, Peter T</creatorcontrib><creatorcontrib>Pedersen, Ole L</creatorcontrib><creatorcontrib>Pedersen, Anders K</creatorcontrib><title>A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome</title><title>Journal of the American College of Cardiology</title><addtitle>J Am Coll Cardiol</addtitle><description>A randomized trial was done to compare single-chamber atrial (AAI) and dual-chamber (DDD) pacing in patients with sick sinus syndrome (SSS). Primary end points were changes in left atrial (LA) size and left ventricular (LV) size and function as measured by M-mode echocardiography. In patients with SSS and normal atrioventricular conduction, it is still not clear whether the optimal pacing mode is AAI or DDD pacing. A total of 177 consecutive patients (mean age 74 +/- 9 years, 73 men) were randomized to treatment with one of three rate-adaptive (R) pacemakers: AAIR (n = 54), DDDR with a short atrioventricular delay (n = 60) (DDDR-s), or DDDR with a fixed long atrioventricular delay (n = 63) (DDDR-l). Before pacemaker implantation and at each follow-up, M-mode echocardiography was done to measure LA and LV diameters. Left ventricular fractional shortening (LVFS) was calculated. Analysis was on an intention-to-treat basis. Mean follow-up was 2.9 +/- 1.1 years. In the AAIR group, no significant changes were observed in LA or LV diameters or LVFS from baseline to last follow-up. In both DDDR groups, LA diameter increased significantly (p &lt; 0.05), and in the DDDR-s group, LVFS decreased significantly (p &lt; 0.01). Atrial fibrillation was significantly less common in the AAIR group, 7.4% versus 23.3% in the DDDR-s group versus 17.5% in the DDDR-l group (p = 0.03, log-rank test). Mortality, thromboembolism, and congestive heart failure did not differ between groups. During a mean follow-up of 2.9 +/- 1.1 years, DDDR pacing causes increased LA diameter, and DDDR pacing with a short atrioventricular delay also causes decreased LVFS. No changes occur in LA or LV diameters or LVFS during AAIR pacing. Atrial fibrillation is significantly less common during AAIR pacing.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Body Weights and Measures</subject><subject>Cardiac Pacing, Artificial - methods</subject><subject>Echocardiography</subject><subject>Female</subject><subject>Heart Atria - diagnostic imaging</subject><subject>Heart Atria - physiopathology</subject><subject>Heart Ventricles - diagnostic imaging</subject><subject>Heart Ventricles - physiopathology</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Sick Sinus Syndrome - diagnostic imaging</subject><subject>Sick Sinus Syndrome - therapy</subject><issn>0735-1097</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNo9UMtOwzAQ9AFES-ETQD4hOATsOE9uVcVLqsQBOEfOetsaEjvYDqh8CN-LxeuyK-3MzoyGkCPOzjnjxcUDK0WecFaXp0ycMVbmZZLvkOn_eUL2vX9mjBUVr_fIhKe1SPOaTcnnnDpplO31ByoKth-k094aaldUBqdlRyNM1Si7BDayb9HRQYI2a6oN5WUZf4xHGIN-w4gEjSZ4-q7DhnoNL3GY0VO_NcrZHi8pwsaCdErbtZPDRsO3PnTaaIhmdgwxBB6Q3ZXsPB7-7hl5ur56XNwmy_ubu8V8mUCMHxKVcrkqJOcoRJ22WOQZ5kJhhVArVqHiGWNVm7cZr9oMZJ2qrFBQ1lDl2FYgZuTkR3dw9nVEH5pee8Cukwbt6JtYYMq5KCPx-Jc4tj2qZnC6l27b_DUpvgB9oHf8</recordid><startdate>20030820</startdate><enddate>20030820</enddate><creator>Nielsen, Jens C</creator><creator>Kristensen, Lene</creator><creator>Andersen, Henning R</creator><creator>Mortensen, Peter T</creator><creator>Pedersen, Ole L</creator><creator>Pedersen, Anders K</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20030820</creationdate><title>A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome</title><author>Nielsen, Jens C ; Kristensen, Lene ; Andersen, Henning R ; Mortensen, Peter T ; Pedersen, Ole L ; Pedersen, Anders K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c259t-d21af6a11e3392be654e53de8ec9d08ed14008b5b418b4ca92d46dc79c85eb8c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Body Weights and Measures</topic><topic>Cardiac Pacing, Artificial - methods</topic><topic>Echocardiography</topic><topic>Female</topic><topic>Heart Atria - diagnostic imaging</topic><topic>Heart Atria - physiopathology</topic><topic>Heart Ventricles - diagnostic imaging</topic><topic>Heart Ventricles - physiopathology</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Sick Sinus Syndrome - diagnostic imaging</topic><topic>Sick Sinus Syndrome - therapy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nielsen, Jens C</creatorcontrib><creatorcontrib>Kristensen, Lene</creatorcontrib><creatorcontrib>Andersen, Henning R</creatorcontrib><creatorcontrib>Mortensen, Peter T</creatorcontrib><creatorcontrib>Pedersen, Ole L</creatorcontrib><creatorcontrib>Pedersen, Anders K</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American College of Cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nielsen, Jens C</au><au>Kristensen, Lene</au><au>Andersen, Henning R</au><au>Mortensen, Peter T</au><au>Pedersen, Ole L</au><au>Pedersen, Anders K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome</atitle><jtitle>Journal of the American College of Cardiology</jtitle><addtitle>J Am Coll Cardiol</addtitle><date>2003-08-20</date><risdate>2003</risdate><volume>42</volume><issue>4</issue><spage>614</spage><epage>623</epage><pages>614-623</pages><issn>0735-1097</issn><abstract>A randomized trial was done to compare single-chamber atrial (AAI) and dual-chamber (DDD) pacing in patients with sick sinus syndrome (SSS). Primary end points were changes in left atrial (LA) size and left ventricular (LV) size and function as measured by M-mode echocardiography. In patients with SSS and normal atrioventricular conduction, it is still not clear whether the optimal pacing mode is AAI or DDD pacing. A total of 177 consecutive patients (mean age 74 +/- 9 years, 73 men) were randomized to treatment with one of three rate-adaptive (R) pacemakers: AAIR (n = 54), DDDR with a short atrioventricular delay (n = 60) (DDDR-s), or DDDR with a fixed long atrioventricular delay (n = 63) (DDDR-l). Before pacemaker implantation and at each follow-up, M-mode echocardiography was done to measure LA and LV diameters. Left ventricular fractional shortening (LVFS) was calculated. Analysis was on an intention-to-treat basis. Mean follow-up was 2.9 +/- 1.1 years. In the AAIR group, no significant changes were observed in LA or LV diameters or LVFS from baseline to last follow-up. In both DDDR groups, LA diameter increased significantly (p &lt; 0.05), and in the DDDR-s group, LVFS decreased significantly (p &lt; 0.01). Atrial fibrillation was significantly less common in the AAIR group, 7.4% versus 23.3% in the DDDR-s group versus 17.5% in the DDDR-l group (p = 0.03, log-rank test). Mortality, thromboembolism, and congestive heart failure did not differ between groups. During a mean follow-up of 2.9 +/- 1.1 years, DDDR pacing causes increased LA diameter, and DDDR pacing with a short atrioventricular delay also causes decreased LVFS. No changes occur in LA or LV diameters or LVFS during AAIR pacing. Atrial fibrillation is significantly less common during AAIR pacing.</abstract><cop>United States</cop><pmid>12932590</pmid><doi>10.1016/S0735-1097(03)00757-5</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0735-1097
ispartof Journal of the American College of Cardiology, 2003-08, Vol.42 (4), p.614-623
issn 0735-1097
language eng
recordid cdi_proquest_miscellaneous_73521137
source BACON - Elsevier - GLOBAL_SCIENCEDIRECT-OPENACCESS
subjects Aged
Aged, 80 and over
Body Weights and Measures
Cardiac Pacing, Artificial - methods
Echocardiography
Female
Heart Atria - diagnostic imaging
Heart Atria - physiopathology
Heart Ventricles - diagnostic imaging
Heart Ventricles - physiopathology
Humans
Male
Middle Aged
Sick Sinus Syndrome - diagnostic imaging
Sick Sinus Syndrome - therapy
title A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T19%3A55%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20randomized%20comparison%20of%20atrial%20and%20dual-chamber%20pacing%20in%20177%20consecutive%20patients%20with%20sick%20sinus%20syndrome:%20echocardiographic%20and%20clinical%20outcome&rft.jtitle=Journal%20of%20the%20American%20College%20of%20Cardiology&rft.au=Nielsen,%20Jens%20C&rft.date=2003-08-20&rft.volume=42&rft.issue=4&rft.spage=614&rft.epage=623&rft.pages=614-623&rft.issn=0735-1097&rft_id=info:doi/10.1016/S0735-1097(03)00757-5&rft_dat=%3Cproquest_pubme%3E73521137%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c259t-d21af6a11e3392be654e53de8ec9d08ed14008b5b418b4ca92d46dc79c85eb8c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=73521137&rft_id=info:pmid/12932590&rfr_iscdi=true