Internal jugular catheterisation. A review of a potentially lethal hazard

A case is presented of near fatal haemorrhage into the pleural space following laceration of a vertebral artery during attempted cannulation of the internal jugular vein before cardiopulmonary bypass. The literature on similar cases is reviewed and recommendations made.

Saved in:
Bibliographic Details
Published in:Anaesthesia 1981-05, Vol.36 (5), p.512-517
Main Authors: Morgan, R N, Morrell, D F
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A case is presented of near fatal haemorrhage into the pleural space following laceration of a vertebral artery during attempted cannulation of the internal jugular vein before cardiopulmonary bypass. The literature on similar cases is reviewed and recommendations made.