Pulmonary vein isolation using transvenous catheter cryoablation for treatment of atrial fibrillation without risk of pulmonary vein stenosis
We sought to evaluate the efficacy and safety of pulmonary vein (PV) isolation using transvenous cryoablation for the treatment of atrial fibrillation (AF). Although electrical isolation of PVs with radiofrequency energy for the treatment of AF is feasible, it is associated with a significant risk o...
Saved in:
Published in: | Journal of the American College of Cardiology 2003-08, Vol.42 (4), p.752-758 |
---|---|
Main Authors: | , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We sought to evaluate the efficacy and safety of pulmonary vein (PV) isolation using transvenous cryoablation for the treatment of atrial fibrillation (AF).
Although electrical isolation of PVs with radiofrequency energy for the treatment of AF is feasible, it is associated with a significant risk of PV stenosis. Cryoablation is a new alternative therapy allowing ablation of tissue while preserving its underlying architecture.
In 52 patients with paroxysmal (n = 45) or persistent (n = 7) AF, PV isolation using the CryoCor cryoablation system (CyroCor Inc., San Diego, California) with a 10F deflectable transvenous catheter was performed as guided by ostial PV potentials. Cryoablation was applied twice at each targeted site (2.5 to 5 min/application). Computed tomography (CT) of the thorax was performed at baseline and at 3 and 12 months to evaluate for PV stenosis.
All targeted PVs were completely isolated in 49 (94%) of 52 of patients. Of 152 PVs targeted, 147 (97%) were successfully isolated (mean 3.0 PVs isolated per patient). After a mean period of 12.4 ± 5.5 months of follow-up, 37 (71%) of 52 patients had no recurrence of AF or were clinically improved, including 29 patients (56%) who had no recurrence of AF with (n = 11) or without the use of anti-arrhythmic drugs. At 3 and 12 months, the CT scan showed no evidence of PV stenosis associated with cryoablation in any patients.
Transvenous catheter cryoablation is an effective method to create PV electrical isolation for the treatment of AF. A clinically satisfactory result can be achieved in 71% of patients with AF, without the risk of PV stenosis. |
---|---|