Loading…

Determination of Flurbiprofen and Ibuprofen in Dog Serum with Automated Sample Preparation

for the determination of flurbiprofen and ibuprofen in dog serum were developed using high‐performance liquid chromatography and automated serum extraction. Sample extraction was automated by use of cartridges packed with a styrene‐divinylbenzene macroreticular resin in a microprocessor‐controlled c...

Full description

Saved in:
Bibliographic Details
Published in:Journal of pharmaceutical sciences 1981-12, Vol.70 (12), p.1347-1349
Main Authors: Snider, B.G., Beaubien, L.J., Sears, D.J., Rahn, P.D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4275-c2cee3fb8c0d8e8573d6c56d81c2fc3f28387312841efcc5ed5cde0eace88d973
cites cdi_FETCH-LOGICAL-c4275-c2cee3fb8c0d8e8573d6c56d81c2fc3f28387312841efcc5ed5cde0eace88d973
container_end_page 1349
container_issue 12
container_start_page 1347
container_title Journal of pharmaceutical sciences
container_volume 70
creator Snider, B.G.
Beaubien, L.J.
Sears, D.J.
Rahn, P.D.
description for the determination of flurbiprofen and ibuprofen in dog serum were developed using high‐performance liquid chromatography and automated serum extraction. Sample extraction was automated by use of cartridges packed with a styrene‐divinylbenzene macroreticular resin in a microprocessor‐controlled centrifugal system. The average recoveries were 98.9% for flurbiprofen and 94.5% for ibuprofen. The limits of detection were ˜0.04 μg/ml for flurbiprofen at 254 nm and 0.5 μg/ml for ibuprofen at 230 nm. The relative standard deviations for the determination of a laboratory standard between days was 2.4% (20 μg/ml) for flurbiprofen and 1.7% (13 μg/ml) for ibuprofen. Peak height ratios were linear with concentrations of 0.04‐100 μg/ml for flurbiprofen and 1.0‐50 μg/ml for ibuprofen. These methods are simple, rapid, sensitive, and specific. The use of an automated sample preparation procedure improved the between‐day precision by a factor of two when compared to a manual extraction procedure. These methods were applied to bioavailability studies in dogs.
doi_str_mv 10.1002/jps.2600701215
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73849436</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022354915439784</els_id><sourcerecordid>73849436</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4275-c2cee3fb8c0d8e8573d6c56d81c2fc3f28387312841efcc5ed5cde0eace88d973</originalsourceid><addsrcrecordid>eNqFkElLLDEURoMovnbYunuQlbtqM1Qq6aW0M6IN7QBuQjq59YzWZFLl8O8trcaHC3EVwv2-k5uD0A4lY0oI23to4phlhEhCGRUraEQFI0lGqFxFoz7AEi7SyR-0EeMDISQjQqyjdckZUYKO0N0BtBBKX5nW1xWuc3xUdGHhm1DnUGFTOXy66JY3X-GD-h-eQ-hK_OLbe7zftXVpWnB4bsqmADwL0JjwCdtCa7kpImwvz010fXR4NT1Jzi-PT6f754lNmRSJZRaA5wtliVOghOQusyJzilqWW54zxZXklKmUQm6tACesAwLGglJuIvkm2h24_ZZPHcRWlz5aKApTQd1FLblKJynP-uB4CNpQxxgg103wpQlvmhL9IVP3MvV_mX3h75LcLUpwX_GlvX4-GeYvvoC3X2j6bDb_xk6Gro8tvH51TXjUmeRS6NuLYz2jNyfTO3qmP95SQx56lc8ego7WQ2XB-QC21a72P33jHc34o6I</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73849436</pqid></control><display><type>article</type><title>Determination of Flurbiprofen and Ibuprofen in Dog Serum with Automated Sample Preparation</title><source>Wiley-Blackwell Journals</source><creator>Snider, B.G. ; Beaubien, L.J. ; Sears, D.J. ; Rahn, P.D.</creator><creatorcontrib>Snider, B.G. ; Beaubien, L.J. ; Sears, D.J. ; Rahn, P.D.</creatorcontrib><description>for the determination of flurbiprofen and ibuprofen in dog serum were developed using high‐performance liquid chromatography and automated serum extraction. Sample extraction was automated by use of cartridges packed with a styrene‐divinylbenzene macroreticular resin in a microprocessor‐controlled centrifugal system. The average recoveries were 98.9% for flurbiprofen and 94.5% for ibuprofen. The limits of detection were ˜0.04 μg/ml for flurbiprofen at 254 nm and 0.5 μg/ml for ibuprofen at 230 nm. The relative standard deviations for the determination of a laboratory standard between days was 2.4% (20 μg/ml) for flurbiprofen and 1.7% (13 μg/ml) for ibuprofen. Peak height ratios were linear with concentrations of 0.04‐100 μg/ml for flurbiprofen and 1.0‐50 μg/ml for ibuprofen. These methods are simple, rapid, sensitive, and specific. The use of an automated sample preparation procedure improved the between‐day precision by a factor of two when compared to a manual extraction procedure. These methods were applied to bioavailability studies in dogs.</description><identifier>ISSN: 0022-3549</identifier><identifier>EISSN: 1520-6017</identifier><identifier>DOI: 10.1002/jps.2600701215</identifier><identifier>PMID: 7320851</identifier><language>eng</language><publisher>Washington: Elsevier Inc</publisher><subject>Animals ; Autoanalysis - methods ; Bioavailability-determination of flurbiprofen and ibuprofen in dog serum with automated sample preparation ; Chromatography, High Pressure Liquid - methods ; Dogs ; Flurbiprofen - blood ; Flurbiprofen-determination in dog serum with automated sample preparation ; Hydrogen-Ion Concentration ; Ibuprofen - blood ; Ibuprofen-determination in dog serum with automated sample preparation ; Propionates - blood</subject><ispartof>Journal of pharmaceutical sciences, 1981-12, Vol.70 (12), p.1347-1349</ispartof><rights>1981 Wiley-Liss, Inc., A Wiley Company</rights><rights>Copyright © 1981 Wiley‐Liss, Inc., A Wiley Company</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4275-c2cee3fb8c0d8e8573d6c56d81c2fc3f28387312841efcc5ed5cde0eace88d973</citedby><cites>FETCH-LOGICAL-c4275-c2cee3fb8c0d8e8573d6c56d81c2fc3f28387312841efcc5ed5cde0eace88d973</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjps.2600701215$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjps.2600701215$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7320851$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Snider, B.G.</creatorcontrib><creatorcontrib>Beaubien, L.J.</creatorcontrib><creatorcontrib>Sears, D.J.</creatorcontrib><creatorcontrib>Rahn, P.D.</creatorcontrib><title>Determination of Flurbiprofen and Ibuprofen in Dog Serum with Automated Sample Preparation</title><title>Journal of pharmaceutical sciences</title><addtitle>J. Pharm. Sci</addtitle><description>for the determination of flurbiprofen and ibuprofen in dog serum were developed using high‐performance liquid chromatography and automated serum extraction. Sample extraction was automated by use of cartridges packed with a styrene‐divinylbenzene macroreticular resin in a microprocessor‐controlled centrifugal system. The average recoveries were 98.9% for flurbiprofen and 94.5% for ibuprofen. The limits of detection were ˜0.04 μg/ml for flurbiprofen at 254 nm and 0.5 μg/ml for ibuprofen at 230 nm. The relative standard deviations for the determination of a laboratory standard between days was 2.4% (20 μg/ml) for flurbiprofen and 1.7% (13 μg/ml) for ibuprofen. Peak height ratios were linear with concentrations of 0.04‐100 μg/ml for flurbiprofen and 1.0‐50 μg/ml for ibuprofen. These methods are simple, rapid, sensitive, and specific. The use of an automated sample preparation procedure improved the between‐day precision by a factor of two when compared to a manual extraction procedure. These methods were applied to bioavailability studies in dogs.</description><subject>Animals</subject><subject>Autoanalysis - methods</subject><subject>Bioavailability-determination of flurbiprofen and ibuprofen in dog serum with automated sample preparation</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Dogs</subject><subject>Flurbiprofen - blood</subject><subject>Flurbiprofen-determination in dog serum with automated sample preparation</subject><subject>Hydrogen-Ion Concentration</subject><subject>Ibuprofen - blood</subject><subject>Ibuprofen-determination in dog serum with automated sample preparation</subject><subject>Propionates - blood</subject><issn>0022-3549</issn><issn>1520-6017</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1981</creationdate><recordtype>article</recordtype><recordid>eNqFkElLLDEURoMovnbYunuQlbtqM1Qq6aW0M6IN7QBuQjq59YzWZFLl8O8trcaHC3EVwv2-k5uD0A4lY0oI23to4phlhEhCGRUraEQFI0lGqFxFoz7AEi7SyR-0EeMDISQjQqyjdckZUYKO0N0BtBBKX5nW1xWuc3xUdGHhm1DnUGFTOXy66JY3X-GD-h-eQ-hK_OLbe7zftXVpWnB4bsqmADwL0JjwCdtCa7kpImwvz010fXR4NT1Jzi-PT6f754lNmRSJZRaA5wtliVOghOQusyJzilqWW54zxZXklKmUQm6tACesAwLGglJuIvkm2h24_ZZPHcRWlz5aKApTQd1FLblKJynP-uB4CNpQxxgg103wpQlvmhL9IVP3MvV_mX3h75LcLUpwX_GlvX4-GeYvvoC3X2j6bDb_xk6Gro8tvH51TXjUmeRS6NuLYz2jNyfTO3qmP95SQx56lc8ego7WQ2XB-QC21a72P33jHc34o6I</recordid><startdate>198112</startdate><enddate>198112</enddate><creator>Snider, B.G.</creator><creator>Beaubien, L.J.</creator><creator>Sears, D.J.</creator><creator>Rahn, P.D.</creator><general>Elsevier Inc</general><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198112</creationdate><title>Determination of Flurbiprofen and Ibuprofen in Dog Serum with Automated Sample Preparation</title><author>Snider, B.G. ; Beaubien, L.J. ; Sears, D.J. ; Rahn, P.D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4275-c2cee3fb8c0d8e8573d6c56d81c2fc3f28387312841efcc5ed5cde0eace88d973</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1981</creationdate><topic>Animals</topic><topic>Autoanalysis - methods</topic><topic>Bioavailability-determination of flurbiprofen and ibuprofen in dog serum with automated sample preparation</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Dogs</topic><topic>Flurbiprofen - blood</topic><topic>Flurbiprofen-determination in dog serum with automated sample preparation</topic><topic>Hydrogen-Ion Concentration</topic><topic>Ibuprofen - blood</topic><topic>Ibuprofen-determination in dog serum with automated sample preparation</topic><topic>Propionates - blood</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Snider, B.G.</creatorcontrib><creatorcontrib>Beaubien, L.J.</creatorcontrib><creatorcontrib>Sears, D.J.</creatorcontrib><creatorcontrib>Rahn, P.D.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of pharmaceutical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Snider, B.G.</au><au>Beaubien, L.J.</au><au>Sears, D.J.</au><au>Rahn, P.D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of Flurbiprofen and Ibuprofen in Dog Serum with Automated Sample Preparation</atitle><jtitle>Journal of pharmaceutical sciences</jtitle><addtitle>J. Pharm. Sci</addtitle><date>1981-12</date><risdate>1981</risdate><volume>70</volume><issue>12</issue><spage>1347</spage><epage>1349</epage><pages>1347-1349</pages><issn>0022-3549</issn><eissn>1520-6017</eissn><abstract>for the determination of flurbiprofen and ibuprofen in dog serum were developed using high‐performance liquid chromatography and automated serum extraction. Sample extraction was automated by use of cartridges packed with a styrene‐divinylbenzene macroreticular resin in a microprocessor‐controlled centrifugal system. The average recoveries were 98.9% for flurbiprofen and 94.5% for ibuprofen. The limits of detection were ˜0.04 μg/ml for flurbiprofen at 254 nm and 0.5 μg/ml for ibuprofen at 230 nm. The relative standard deviations for the determination of a laboratory standard between days was 2.4% (20 μg/ml) for flurbiprofen and 1.7% (13 μg/ml) for ibuprofen. Peak height ratios were linear with concentrations of 0.04‐100 μg/ml for flurbiprofen and 1.0‐50 μg/ml for ibuprofen. These methods are simple, rapid, sensitive, and specific. The use of an automated sample preparation procedure improved the between‐day precision by a factor of two when compared to a manual extraction procedure. These methods were applied to bioavailability studies in dogs.</abstract><cop>Washington</cop><pub>Elsevier Inc</pub><pmid>7320851</pmid><doi>10.1002/jps.2600701215</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-3549
ispartof Journal of pharmaceutical sciences, 1981-12, Vol.70 (12), p.1347-1349
issn 0022-3549
1520-6017
language eng
recordid cdi_proquest_miscellaneous_73849436
source Wiley-Blackwell Journals
subjects Animals
Autoanalysis - methods
Bioavailability-determination of flurbiprofen and ibuprofen in dog serum with automated sample preparation
Chromatography, High Pressure Liquid - methods
Dogs
Flurbiprofen - blood
Flurbiprofen-determination in dog serum with automated sample preparation
Hydrogen-Ion Concentration
Ibuprofen - blood
Ibuprofen-determination in dog serum with automated sample preparation
Propionates - blood
title Determination of Flurbiprofen and Ibuprofen in Dog Serum with Automated Sample Preparation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T05%3A46%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20Flurbiprofen%20and%20Ibuprofen%20in%20Dog%20Serum%20with%20Automated%20Sample%20Preparation&rft.jtitle=Journal%20of%20pharmaceutical%20sciences&rft.au=Snider,%20B.G.&rft.date=1981-12&rft.volume=70&rft.issue=12&rft.spage=1347&rft.epage=1349&rft.pages=1347-1349&rft.issn=0022-3549&rft.eissn=1520-6017&rft_id=info:doi/10.1002/jps.2600701215&rft_dat=%3Cproquest_cross%3E73849436%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4275-c2cee3fb8c0d8e8573d6c56d81c2fc3f28387312841efcc5ed5cde0eace88d973%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=73849436&rft_id=info:pmid/7320851&rfr_iscdi=true